Low Height Compression Load Cell Force Sensor FHA is produced based on strain gauge technology with CE certified. Low profile load cell FHA offers 0-30kg / 0-75kg / 0-150kg / 0-300kg four rated measuring ranges to choose form, high accuracy with 0.05% non-linearity of the full capacity. Thin load cell FHA utilizes 1000ohms gauges which has better performance compared to commonly used 350ohms gauges in terms of power consumption and long term stability. Compact design enables the construction of scales with an extremely low overall height, affordable load cell FHA is also suitable for battery powered weighing devices.
Specifications
Rated capacity | 30kg / 300N / 66 lb 75kg / 750N / 165 lb 150kg / 1500N / 330 lb 300kg / 3000N / 660 lb | ||
Rated output | 1.5/2.0 mV/V | Compensated temperature | 0...+25oC |
Excitation | 3-10V | Operating temperature | -10...+40oC |
Zero balance | ±0.1mV/V | Temperature shift zero | ±0.2% R.O./oC |
Nonlinearity | ±0.05% R.O. | Temperature shift span | ±0.05% R.O./10oC |
Hysteresis | ±0.05% R.O. | Input resistance | 1120±50 ohms |
Nonrepeatability | ±0.05% R.O. | Output resistance | 1000±10 ohms |
Creep(3min) | ±0.05% R.O. | Insulation resistance | >2000Mohms |
Safe overload | 150% F.S. | Ingress protection | IP65 |
Ultimate overload | 200% F.S. | Material of element | Aluminum alloy |
Cable | 30kg/75kg — 32AWG 400mm 4-wire 150kg/300kg — 32AWG 150mm 4-wire | ||
Wiring code | Red--Excitation+ Black--Excitation- Green--Signal+ White--Signal- |
A load cell is a transducer that converts mechanical load into mV signal proportional to the applied load/force.The acting force causes deformation of the measuring element,the bonded strain gage deforms accordingly which will cause the resistance change of the wheatstone bridge,under constant power supply, the output signal between Sig+ and Sig- will change proportionally,thus the load can be measured by measuring the output signal from the transducer which is normally within -30mV...+30mV.
Brief instruction of Rated output(or Sensitivity):
Definition: The signal produced by load cell(or force transducer)
when rated load is applied, expressed in terms of mV/V. The rated
output indicates the output signal range of the sensor.
Sensor output = (Power supply * Rated output) * Load / Capacity
Rated output of thin loadcell FHA normally within 1.5mV/V~2.0mV/V.
Power supply of weight transducer FHA is normally within 3-10V.
Load / Capacity is within 0-1.
So the load cell output signal is normally within 0-20mV.
Example one: Low profile compression load cell FHA-300kg with
2.0mV/V rated output powered by 5V DC ,the output range is 0~10mV.
Example two: Compact weight sensor FHA-150kg with 2mV/V rated
output powered by 10V DC ,the output range is 0~20mV.
Low Profile Weight Sensor 300kg 150kg 100kg 30kg Compact Compression Load Cell