MTL5511 Switch Proximity Detector Interface 25mA 24V

Country/Region china
City & Province hong kong
Categories Level Measuring Instruments
InquireNow

Product Details

MTL5511 SWITCH/ PROXIMITY DETECTOR INTERFACE

The MTLx511 enables a safe-area load to be controlled by a switch or proximity detector located in a hazardous-area. When selected, open or short circuit conditions in the field wiring are detected by the line- fault-detect (LFD) facility and also indicated on the top of the module. Phase reversal for the channel is selected by a switch on the side of the module and output is provided by changeover relay contacts.

 

SPECIFICATION

Location of switches

Zone 0, IIC, T6 hazardous area

Div. 1, Group A hazardous location

Location of proximity detector

Zone 0, IIC, T4–6 hazardous area if suitably certified Div. 1, Group A hazardous location

Hazardous-area inputs

Inputs conforming to BS EN60947–5–6:2001 standards for proximity detectors (NAMUR)

Voltage applied to sensor

7 to 9V dc from 1kΩ ±10%

Input/output characteristics

Normal phase

Outputs closed if input > 2.1mA (< 2kΩ in input circuit) Outputs open if input < 1.2mA (> 10kΩ in input circuit)

Hysteresis: 200µA (650Ω) nominal

Line fault detection (LFD) (when selected)

User-selectable via switches on the side of the unit. A line fault is indicated by an LED. The channel output relay is de-energisedif an input line fault is detected.

Open-circuit alarm on if Iin < 50µA

Open-circuit alarm offif Iin > 250µA

Short-circuit alarm on if Rin < 100Ω

Note: Resistors must be fitted when using the LFD facility with a contact input 500Ω to 1kΩ in series with switch 20kΩ to 25kΩ in parallel with switch

Safe-area output

Single pole relay with changeover contacts

Note: reactive loads must be adequately suppressed

LED indicators

Green: power indication

Yellow: channel status, on when output energised

Red: LFD indication, on when line fault detected

Maximum current consumption

25mA at 24V

Power dissipation within unit

0.6W at 24V

 

 

Related Part Number:

 

 

HCU16MTL5521MTL4546YMTL7761PAC
HCU3700MTL5522MTL4549YMTL7765AC
HM64RIB20-1.0MTL5531MTL4573MTL7787+
HM64RIB20-1.5MTL5532MTL4575MTL7787P+
HMM64MTL5541MTL4646YMTLCPS16
HMRIB16-1.0MTL5541SMTL4850NJ5-18GK-N
HMS64MTL5544MTL4851SD150X
HTP-SC32MTL5544DMTL4852SD32
MTL4044DMTL5546MTL5018SD32X
MTL4511MTL5546YMTL5032SDRTD
MTL4516MTL5561MTL5042SLP32D
MTL4516CMTL5573MTL5044TP48-3-I-NDI
MTL4521MTL5575MTL5049TP48-3-N-NDI
MTL4541MTL5582BMTL5511TP48-4-I-NDI
PCL45USBMTL7728+MTL5514DTP48-4-N-NDI
MTL4544MTL7756ACMTL5516TP48-N-NDI
MTL4544DMTL7760ACMTL5516CZB24571

 

 

Hot Products

Emerson Ovation Analog Input Module 1C31113G05 Emerson offers a wide inventory of factory-certified ...
Rosemount 751 Field Signal Indicator 751AM7I5 Product Description Gain access to important process ...
Rosemount 396 Submersion/Insertion pH Sensor 396-54-62 TUpH sensors for your tough pH/oxidation ...
Rosemount 3051T In-Line Transmitter 3051TG5A2B21AB4M5K5HR5 Rosemount 3051T In-Line Pressure ...
Rosemount 3051C Coplanar Pressure Transmitter 3051CD2A22A1BI1M5Q4 Rosemount 3051C Coplanar Pressure ...
Bently Nevada 3500/65 16-Channel Temperature Monitor 3500/65-01-00 145988-02 172115-01 Description ...