Quick Details
Burner operation process
1. Start the power control button on the control cabinet. At this
time, the digital display will show the current temperature of the
furnace. The temperature of Xinan's furnace body is the ambient
temperature.
2. Start the fan control button, and the fan installed on the
furnace body will work. At this time, if the fan damages the
control cabinet, it will automatically protect against the next
operation.
3. When the combustion-supporting fan works without abnormal
phenomena, the combustion control button is restarted. At this
time, the combustion program controller starts to work. It performs
ignition, air supply, flame detection, etc. through certain
procedures to finally achieve safe combustion.
Model Table
item | Burner output | Width | Height | Thickness | Weight | Air consumption |
KW(KCAL/H) | mm | mm | mm | kg | m3 |
SBJ-300 | 190-465 | 630 | 400 | 480 | 32.2 | 3.8-9.3 |
SBJ-400 | 300-697 | 670 | 450 | 530 | 42.8 | 5.8-13.9 |
SBJ-600 | 486-1279 | 710 | 500 | 580 | 25.9 | 15.9-23.8 |
Sort | name |
1 | Combustion Combustion Fan |
2 | Wind pressure switch |
3 | Burner nozzle |
4 | Proportional butterfly valve |
5 | Gas ball valve |
6 | Photoelectric switch |
7 | Proportional motor |
8 | Control box |
9 | Pressure gauge |
10 | Fan filter |
11 | Gas pressure switch |
12 | Gas main safety valve |
13 | Ignition transformer |
14 | Mother Fire Solenoid Valve |
15 | Fire solenoid valve |
16 | Spherical needle valve |
17 | Ignition rod |
18 | Burning firebox |