Residential Inline Water Flow Meter LCD Irrigation Mass Flow Measurement
 
Detailed Product Description
Type:Inline Ultrasonic Flow MeterDisplay:LCD
Transducer:Inline / Clamp On / InsertAccuracy:+/- 1%
Communication:4-20 MA / OCT Pulse / RelaySize:DN50-700
Temperature:90 C / 160 CPipe Material:Weld Steel, Stainless Steel, Cast Iron, Copper / Brass, Cement Pipe, Aluminum
 

 

Fixed Inline ultrasonic flowmeters by transit time multi-liquid velocity determine for slurry | effluent | sewage

 

General of ultrasonic flow meters

The UFM Ultrasonic flowmeters can determine the velocity of a fluid flowing in a pipe by sound waves. When it's in no flow conditions, an ultrasonic wave's frequencies are transmitted into a pipe and its reflections from the fluid are the same. When it's under flowing conditions, the frequency of the reflected wave is different due to the Doppler effect. When liquid media moves faster, the frequency shift increases linearly. The transmitter processes signals from the transmitted wave and its reflections to determine the flow rate.

The transit time type ultrasonic flowmeters can give and receive ultrasonic waves between the transducers in both the upstream and downstream in the pipe. While it's under no flow conditions, it takes the same time to travel upstream and downstream between the transducers. While it's under flowing conditions, the upstream wave will travel slower and take more time than the (faster) downstream wave. When the fluid moves faster, the difference between the upstream and downstream times increases. The transmitter processes upstream and downstream times to determine the flow rate.

 

Data sheet

Accuracy <1%

Flow rate 0 - 10m/s, bi-direction

Pipe diameter DN32 - DN6000 mm

Liquid temperature -30℃ - 160℃

Liquid type water, sea water, sewage, effluent, oil, alcohol, any single liquid that can

transmit ulstrasonic wave

Pipe material stainless steel, cast iron, copper, PVC, aluminum, fiber glass steel

Output one way 4-20mA, one way OCT pulse, one way replay

Input three way 4-20mA, PT1000 platinum resistor for heat measurement

Communication RS485, MODBUS

Data storage SD card

Power supply DC8-36V / AC85-264V

Protection IP65 (main body), IP68 (transducer)

Humidity <85% RH

Ambient temperature -20℃ - 60℃

 

Description:

The ultrasonic flowmeter is available with pipe type, clamp on and other options, it's designed for linear and bi-directional volumetric flow measurement of liquid. The measured flow datas can be output by standard analog or pulse or frequency. Through HMI user friendly operator interface, the unit can be set up for a wide range of applications. Next to actual volumetric flow measurement, the unit can be configured to perform flow totalization ( plus, minus, or sum). Measurement and output of the liquid sonic velocity can be configured too.

 

Optionally the unit can be set to perform one of the following additional functions:

  • Calculate and output corrected standard volumetric or mass flow using external pressure & temperature inputs
  • Batch function
  • Heat function, combining T1, T2 and volume

Metering Diagram

Flow measurement Heat measurement

Fixed Inline Ultrasonic Flowmeters By Transit Time Multi - Liquid Velocity Determine

Reference chart

TypeModelPipe dia (mm)TemperatureDimension (mm)
Clamp onTS-2DN15-100-30-90℃45x25x32
TM-1DN50-700-30-90℃64x39x44
TL-1DN300-6000-30-90℃97x54x53
Clamp on (high temperature)TS-2-HTDN15-100-30-90℃45x25x32
TM-1-HTDN50-700-30-90℃64x39x44
TL-1-HTDN300-6000-30-90℃97x54x53
Insertion typeTC-1DN80-6000-30-90℃190x80x55
TC-2(lengthen)DN80-6000-30-90℃335x80x55
Pipe typeG3 (π type)DN15-25-30-160℃ 
G2DN32/DN40-30-160℃ 
G3DN50-6000-30-160℃ 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Optional temperature transducer

SpecificationModelDiaTemp.Water cutAccuracy
Clamp-on temp. transducer Pt100CT-1>DN50-40-160℃No100+ 0.8℃
Insertion temp. Transducer Pt100TCT-1Yes
Insertion temp. Pt100 with pressurePCT-1No
Insertion temp.Pt100 for small pipe DSCT-1<DN50Yes

 

 

 

 

 

 

 

 

Industries

  • Chemicals
  • Petrochemicals
  • Oil & Gas
  • Heating, Ventilation & Air Conditioning (HVAC)
  • Power Plants
  • Water treatment

Liquid type

  • Metering of cooling water
  • Demineralisedwater
  • Control of batching and blending operations
  • Mass flow measurement
  • Allocation measurement
  • District heating
  • Irrigation
  • Energy measurement

Model Selection

IModel       
 YFElectromagnetic flowmeter
 TFTurbine
 VFVotex
 LXVane wheel
 TUltrasonic
  E/F display modeE: compact/local display, F: remote display
   Pipe DiaType (mm)
   xxxx

10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300,

400, 500, 600, 800, 1000

   CodeAccuracy
   1+ 0.5% FS
   2+ 1.0% FS
   3+ 0.2% FS
    CodeType
    NConverter: 12 / 24 VDC, pulse output
    ATransmitter: 24VDC, 4-20mA outpt
    BIntelligent, Lion battery, no local display
    GSmart, local display, 4-20mA output
    C1Smart, local display, RS485
    C2Smart, local display, HART
     CodeType
     SCarbon steel housing
     LStainless steel housing
     GHigh pressure housing
     HL316L electrode
     HTiTitanium electrode
     HTaTantlum electrode
     HCHastelloy-C electrode
     L1Liquid media
     L2Gas media
     PPressure compensation
     TTemperature compensation
     PTPressure&Temp. Compensation
     FPTFE liner
     XRubber liner

Sample: IYF-E-0100-1-C1-S-HL-L1-F,

Magmeter, local display, Dia: 100mm, + 0.5%FS, carbon steel housing, smart, 4-20mA outpt,

RS485, 316L electrode, liquid media meter, PTFE liner

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Competitive Advantage:

  • Compliance to international standards: ISO9001-2008 / GB/T19001 / MC00000-044/507
  • CE approval
  • Strict process control
  • Advanced calibration equipment
  • Engineer team

Hot Products

High pressure pump Seawater RO Plant for seawater desalination 750 m3 / day 1. Operation Specificati...
Containerized Seawater Reverse Osmosis Plant for drinking water production 500 m3/day 1. Operation ...
Seawater RO Plant with energy recovery for seawater desalination 2x1000 m3 / day​ 1. Operation ...
High TDS seawater RO plant for drinking water production 360m3/hr​ 1. Operation Specifications: Feed ...
High TDS seawater RO plant for drinking water production 360m3/hr​ 1. Operation Specifications: Feed ...
Mobile Containerized Seawater RO Plant for drinking water production 36 m3/hour 750m3/hour 1. ...