Electromagnetic flowmeter for slurry flow meter in sewage treatment plant DN100 Rubber liner

 

Product Description

The YF series electromagnetic flow meter can be with signal output of 4-20mA and/or pulse output. The flow transmitter can be mounted either integrally to the flow sensor or remotely. The transmitter features a three-line LCD that displays the flow total, flow velocity, flow rate percent of range, and alarm settings. A four-button keypad is used to change settings. There are 27 flow unit options to choose from programmed into the transmitter.

 

Key Features

  • Suitable to meter for wide range of conductive liquid media
  • Virtually no pressure loss
  • No Moving Parts
  • Flanges port connection
  • RS485 Standard
  • Suitable for Pipes diameter p to 2000 mm
  • Large meter ratio
  • High Accuracy
  • 4 to 20 mA / Frequency / Pulse output

Grounding

From flow meter housing terminal G to grounding by minimal 1.6mm2 copper cable, resistivity < 10 Ω.

 

Technical data

Product name

Electromagnetic flowmeter

Product type

Local|compact display

Remote display

Signal converter

Model

IYF-E

IYF-F

IRT

Pipe Diameter (mm)

DN10-DN2000

Power supply

100-240 VAC / 18-36 VDC

Accuracy

+ 0.5% 

+ 0.5%

+ 0.5%

Power consumption

<6w

<6w

<6w

Enclosure rating

IP65

IP68

IP65

Liquid temperature

-25-120℃

-25-120℃

-25-120℃

Ambient temperature

-25-50℃

-25-50℃

-25-50℃

Relative humidity

10-90%

10-90%

10-90%

Meter ratio

1:100

1:100

1:100

Flow direction

Bi-direction flow

Bi-direction flow

Bi-direction flow

Communication

RS485 / Bacnet

RS485 / Bacnet

RS485 / Bacnet

Signal Output

4-20mA/Pulse/Frequency

4-20mA/Pulse/Frequency

4-20mA/Pulse/Frequency

 

Accuracy

Pipe Dia (mm)Velocity (m/s)Accuracy
3-20<0.3+ 0.25% FS
0.3-1+ 1.0% Readout
1-15+ 0.25% Readout
25-6000.1-0.3+ 0.25% FS
0.3-1+ 0.5% Readout
1-15+ 0.3% Readout
700-3000<0.3+ 0.25% FS
0.3-1+ 1.0% Readout
1-15+ 0.25% Readout

 

 

 

 

 

 

 

 

 

 

 

 

 

Model selection

Applicable metering liquid:

  • Conductive liquid media, conductivity > 5 µS/ cm
  • Various Conductive aqueous solutions, water solutions, acid & caustics
  • Abrasive slurries, sludges and grease bearing liquids, corrosive liquid, municipal tap water, waste water,dirty
    water, effluent, fibrous, viscous, paper mill, food & beverage

Non-applicable metering medial

  • Industrial gas, compressed air, steam, or liquid with large content of gas
  • Liquid is non-conductive or low conductive, like lubricating oil, clean oil, cryogenic, cooling water, pure 
    water, clean gas, etc. 

Notice on the selection of local type and remote type: 

Remote type means the transmitter and converter display are mounted in different locations, it’s suggested to select 
remote type in the following conditions:

  • Ambient temperature or converter display sunshine temperature is over 60 ℃
  • High humidity or corrosive air existed
  • Serious pipe vibration 
  • Magnetic meter need be suspended or submersible, uneasily read out
  • Other abrasive condition

I

Model

 

 

 

 

 

 

 

 

YF

Electromagnetic flowmeter

 

TF

Turbine

 

VF

Votex

 

LX

Vane wheel

 

T

Ultrasonic

 

 

E/F display mode

E: compact/local display, F: remote display

 

 

 

Pipe Dia

Type (mm)

 

 

 

xxxx

15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 400, 

500, 600, 800, 1000

 

 

 

Code

Accuracy

 

 

 

1

+ 0.5% FS

 

 

 

2

+ 1.0% FS

 

 

 

3

+ 0.2% FS

 

 

 

 

Code

Type

 

 

 

 

N

Converter: 12 / 24 VDC, pulse output

 

 

 

 

A

Transmitter: 24VDC, 4-20mA outpt

 

 

 

 

B

Intelligent, Lion battery, no local display

 

 

 

 

G

Smart, local display, 4-20mA output

 

 

 

 

C1

Smart, local display, RS485

 

 

 

 

C2

Smart, local display, HART

 

 

 

 

 

Code

Type

 

 

 

 

 

S

Carbon steel housing

 

 

 

 

 

L

Stainless steel housing

 

 

 

 

 

G

High pressure housing

 

 

 

 

 

HL

316L electrode

 

 

 

 

 

HTi

Titanium electrode

 

 

 

 

 

HTa

Tantlum electrode

 

 

 

 

 

HC

Hastelloy-C electrode

 

 

 

 

 

L1

Liquid media

 

 

 

 

 

L2

Gas media

 

 

 

 

 

P

Pressure compensation

 

 

 

 

 

T

Temperature compensation

 

 

 

 

 

PT

Pressure&Temp. Compensation

 

 

 

 

 

F

PTFE liner

 

 

 

 

 

X

Rubber liner

Sample: IYF-E-0100-1-C1-S-HL-L1-F, Magmeter, local display, Dia: 100mm, + 0.5%FS, carbon steel housing, 

smart, 4-20mA outpt, RS485,  316L electrodes, liquid media meter, PTFE liner

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pipe Diameter, flow volume and product dimension

Dia

Flow volume (m3/h)

Product dimension (mm)

(mm)

Normal

Min

Max

L

D

H

H1

15

1.5

0.06

9.5

150

95

272

254

20

2.5

0.11

16.9

105

277

254

25

3.5

0.18

26.5

115

283

254

32

6

0.29

43.6

140

297

270

40

10

0.45

67.8

150

307

280

50

15

0.71

106.0

200

165

318

294

65

25

1.19

179.1

185

337

313

80

40

1.81

271.4

200

352

326

100

60

2.83

424.1

250

220

371

344

125

100

4.42

665

250

401

372

150

135

6.36

954

300

285

431

403

200

250

11.3

1696

350

340

486

460

250

375

17.66

2650

400

395

547

511

300

540

25.43

3817

450

445

597

565

350

735

34.62

5195

505

657

620

400

960

45.22

6785

500

565

717

675

450

1200

57.23

8588

550

615

757

727

500

1500

70

10602

600

670

817

782

600

2160

100

15268

780

917

782

700

2950

138

20781

700

895

1027

1068

800

3850

180

27100

800

1015

1137

1157

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Industrial applications

Chemical

Food & beverage

Paper mill

Metallurgy

Environment protection

Hydraulic

Mining

Stainless

Petroleum

Pharmacy

Air conditioner

Effluent treatment plant

Seawater desalination

Pharmacy

Water treatment

 

 

 

 

 

 

Competitive advantage

  • Compliance to international standards: ISO14001, GB/T28001, ISO9001-2008 / GB/T50430
  • Strict process control
  • Advanced calibration equipment
  • Engineer team

 

Hot Products

High pressure pump Seawater RO Plant for seawater desalination 750 m3 / day 1. Operation Specificati...
Containerized Seawater Reverse Osmosis Plant for drinking water production 500 m3/day 1. Operation ...
Seawater RO Plant with energy recovery for seawater desalination 2x1000 m3 / day​ 1. Operation ...
High TDS seawater RO plant for drinking water production 360m3/hr​ 1. Operation Specifications: Feed ...
High TDS seawater RO plant for drinking water production 360m3/hr​ 1. Operation Specifications: Feed ...
Mobile Containerized Seawater RO Plant for drinking water production 36 m3/hour 750m3/hour 1. ...