Home Companies SAAR HK Electronic Limited

10TEN0040-00000A00-P2,2-M-R3, R928054255, Bosch Rexroth, Tank mounted return line filters, MobileHydraulics

SAAR HK Electronic Limited
Active Member

Contact Us

[China] country

Address: Rm 1506,28# Moyu Rd,Shanghai,China

Contact name:Jason Liu

Inquir Now

SAAR HK Electronic Limited

10TEN0040-00000A00-P2,2-M-R3, R928054255, Bosch Rexroth, Tank mounted return line filters, MobileHydraulics

Country/Region china
City & Province shanghai shanghai
InquireNow

Product Details

10TEN0040-00000A00-P2,2-M-R3,    R928054255,    Bosch Rexroth,    Tank mounted return line filters,    10TE(N),   MobileHydraulics


The filter element is the central component of industrial filters. The actual filtration process takes part in the filter element. The main filter variables, such as retention capacity, dirt holding capacity and pressure loss are determined by the filter elements and the filter media used in them.

 

 

 

 

Details
  • Size 0040 … 2500
  • Max. operating pressure 10 bar
  • Flow, max. 1680 l/min
  • Port G3/4, G1 1/4, G1 1/2, SAE 2", 3000 psi, SAE 2 1/2", 3000 psi, SAE 3", 3000 psi, SAE 4", 3000 psi, SAE 4", 3000 psi
  • Operating temperature -10 … +100 °C

 

 

 

Features
  • Filter für Tankanbau
  • Special highly efficient filter media
  • Filtration of very fine particles and high dirt holding capacity across a broad pressure differential range
  • High collapse resistance of the filter elements
  • Optionally equipped with mechanical optical maintenance indicator with memory function
  • Optional equipment with various electrical switching elements, modular design
  • Standardmäßige Filterausstattung mit einem Bypassventil im Filtergehäuse integriert
  • Optional measuring port

 

 

 

Product description


The tank mounted return line filter is provided in the return line for direct attachment onto the tank of a hydraulic or lubrication system. It can also be used as filling or bypass filter. It basically consists of filter head (1), filter bowl (2), cover (3), filter element (4) as well as a bypass valve (5), by default.

Optionally, the filter is equipped with mechanical/visual maintenance indicator (6). The electronic maintenance indicator is connected via the electronic switching element (7) with 1 or 2 switching points (see p. 7), which has to be ordered separately.

During operation, the hydraulic fluid reaches the filter housing via the inlet; here, it flows through the filter element (5) from the outside to the inside and is cleaned according to the filter rating. The dirt particles filtered out settle in the filter bowl (3) and in the filter element (5). Via the outlet, the filtered hydraulic fluid enters the tank. In case of contamination, the necessary filter element exchange is displayed by the maintenance indicator (7).

The electronic switching element (7) is attached to the mechanical/visual maintenance indicator (6) and held by means of a locking ring.

Depending on the filter size, more additional functions (only for NG0040 ... 0100) are available - e.g. a breathing filter (8), surge protection (9) or return pipes (10) in different lengths – in this connection, also refer to the chapter “Ordering code Accessories”.

 

 

 

 

 

 

 

 

 

 

 

 

 

Type code


010203 0405 06 07 08 09
10TE   A00    
Series
01Return flow filter, simple, 10 bar10TE
Filter element
02with filter element according to DIN 24550N
Size
03TEN...
(filter element according to DIN 24550)
0040
0063
0100
0160
0250
0400
0630
1000
TE...
(filter element according to Bosch Rexroth standard)
2000
2500
Filter rating in μm
04NominalPaper, not cleanableP10
P25
NominalStainless steel wire mesh, cleanableG10
G25
G40
G60
G100
Absolute
(ISO 16889; βx(c) ≥ 200)
Non-woven glass fiber media, not cleanableH3XL
H6XL
H20XL
Glass fiber material generation 5, non-reusable, not cleanablePWR10
Absolute
(ISO 16889; βx(c) ≥ 200)
Water-absorbing, not cleanableAS3
AS6
AS10
AS20
Pressure differential
05max. admissible pressure differential of the filter element30 bar ‒ Filter with bypass valveA00
Maintenance indicator
06without maintenance indicatorBypass cracking pressure 3.5 bar0
Pressure gauge 0...6 bar right 1)Bypass cracking pressure 3.5 barMR
Pressure gauge 0…6 bar left1)Bypass cracking pressure 3.5 barML
Maintenance indicator, mech./visual, switching pressure 2.2 barBypass cracking pressure 3.5 barAluminiumMRV2,2
Maintenance indicator, mech./visual, switching pressure 2.2 barAluminiumwithPressure gauge 0...6 bar right 1)Bypass cracking pressure 3.5 barMLV2,2
Maintenance indicator, mech./visual, switching pressure 2.2 barBypass cracking pressure 3.5 barPolyamideP2,2
Maintenance indicator, mech./visual, switching pressure 0.8 barBypass cracking pressure 3.5 barAluminiumV0,8
Maintenance indicator, mechanical/visual, switching pressure 1.5 barBypass cracking pressure 3.5 barAluminiumV1,5
Maintenance indicator, mech./visual, switching pressure 2.2 barBypass cracking pressure 3.5 barAluminiumV2,2
Seal
07NBRM
FKMV
Port
08Frame size00400063…01000160025004000630100020002500 
Port 
G 3/4

x

x

R3
G 1xR4
1 1/16-12 UN-2BxxU4
1 5/16-12 UN-2BxxU9
G1 1/4xR5
G1 1/2xR6
SAE1 1/4 - 3000 psixxS5
SAE1 1/2 - 3000 psixxS6
1 7/8-12 UN-2BxxU6
SAE2" 3000 psixS8
SAE2 1/2" 3000 psixS9
SAE3" 3000 psixxS10
SAE4" 3000 psixS12
Standard portxAlternative connection possibilitynot possible     
Supplementary information
09Breathing filterF
Breathing filter with surge protectionFN
Threaded coupling right (not possible with pressure gauge right)MR
Threaded coupling left (not possible with pressure gauge left)ML
Without bypass valveNB
Outlet pipe L110 mmR110
Outlet pipe L150 mmR150
Outlet pipe L250 mmR250
Further versions are available upon request.
 

 

 

 

 

 

 

 

 

 

 

Technical data


 

General

Type / version 10 TEN10 TE
Size 0040006301000160025004000630100020002500
PortStandard G3/4 G1 1/4G1 1/2SAE 2", 3000 psiSAE 2 1/2", 3000 psiSAE 3", 3000 psiSAE 4", 3000 psi
optional G1
1 1/16-12 UN-2B
1 5/16-12 UN-2B
G3/4
1 1/16-12 UN-2B
1 5/16-12 UN-2B
G1 1/2
SAE 1 1/4“ 3000 psi
SAE 1 1/2“ 3000 psi
1 7/8-12 UN-2B
G1 1/4
SAE 1 1/4“ 3000 psi
SAE 1 1/2“ 3000 psi
1 7/8-12 UN-2B
SAE 2 1/2", 3000 psiSAE 2", 3000 psiSAE 4", 3000 psiSAE 3", 3000 psi
Ambient temperature range°C-10 … +65
Installation position Vertical
Filtration direction From the outside to the inside
Fatigue strength according to ISO 10771 > 10⁵ with max. operating pressure
MaterialFilter cover carbon fiber reinforced plastic
Filter head Aluminium
Filter bowl carbon fiber reinforced plastic
Seals NBR / FKM
Weightkg1.41.61.84.558101821.527

hydraulic

Type / version 10 TEN10 TE
Size 0040006301000160025004000630100020002500
Flow, max.l/min628095260320560630127016001680
Max. operating pressurebar10
Operating temperature range°C-10 … +100
Cracking pressureBypass valvebar3 ±0.3
Hydraulic fluid temperature range°C-10 … +100
Minimum conductivity of the mediumpS/m300

 

Hydraulic fluidClassificationSuitable sealing materialsSuitable adhesiveStandards
Mineral oilHLPNBRStandardDIN 51424
Bio-degradableInsoluble in waterHETGNBRVDMA 24568
HEESFKM
Soluble in waterHEPGFKMVDMA 24568
Flame-resistantWater-freeHFDU, HFDRFKMVDMA 24317
Containing waterHFASNBRDIN 24320
HFAENBR
HFCNBRVDMA 24317
SkydrolEPDMSpecial “H”

Important information on hydraulic fluids!

  • For more information and data on the use of other hydraulic fluids, please refer to data sheet 90220 or contact us!
  • Flame-resistant – containing water: Due to possible chemical reactions with materials or surface coatings of machine and system components, the service life with these hydraulic fluids may be less than expected. Filter materials made of filter paper P must not be used, filter elements with glass fiber material have to be used instead.
  • Bio-degradable: If filter materials made of filter paper are used, the filter life may be shorter than expected due to material incompatibility and swelling.

For applications outside these parameters, please consult us!

 

 

 

 

 

 

 

 

 

 

 

Diagrams/characteristic curves

Filter element (measured with mineral oil HLP46 according to DIN 51524)

Spec. weight: < 0.9 kg/dm3

Δp-Q characteristic curves for complete filter, recommended initial Δp for design = 0.5 bar

Selection of the perfect filter is made possible by our online “Bosch Rexroth FilterSelect“ design software.

 

10TEN0040-H3XL

 

10TEN0063-H3XL

 

10TEN0100-H3XL

 

10TEN0160-H3XL

 

10TEN0250-H3XL

 

10TEN0400-H3XL

 

10TEN0630-H3XL

 

10TEN1000-H3XL

 

10TE2000-H3XL

 

10TE2500-H3XL

 

10TEN0040-H10XL

 

10TEN0063-H10XL

 

10TEN0100-H10XL

 

10TEN0160-H10XL

 

10TEN0250-H10XL

 

10TEN0400-H10XL

 

10TEN0630-H10XL

 

10TEN1000-H10XL

 

10TE2000-H10XL

 

10TE2500-H10XL

 

 
 
 
 
 
 
 

 

Dimensions
 
 
 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

Maintenance


Maintenance

If at operating temperature, the red indicator pin reaches out of the mechanical/visual maintenance indicator and/or if the switching process in the electronic switching element is triggered, the filter element is contaminated and needs to be replaced and cleaned respectively. More details see data sheet for filter elements.

The material number of the corresponding replacement filter element is indicated on the name plate of the complete filter. It must comply with the material number on the filter element.

Switch off the system, discharge the filter on the pressure side.

Screw off the filter cover (NG0040-0100) and/or loosen the screws (from NG0160) and remove the filter cover upwards.

 

Notice:

Note that with lower ratings, it may take slightly longer to discharge the residual oil. If the filter element is removed before the residual oil has been discharged, contaminated oil may reach the clean side.

 

Remove the filter element including filter bowl. From frame size 0160, the filter bowls are equipped with removal brackets.

Remove the filter element from the spigot in the filter bowl by rotating it slightly; clean the filter components if necessary.

Check the seals at filter cover and filter bowl for damage and renew them, if necessary. For suitable seal kits refer to chapter “Ordering code Spare parts”.

Filter elements made of wire mesh can be cleaned. For detailed cleaning instructions refer to the data sheet for filter elements.

Install the new or cleaned filter element on the spigot again by slightly rotating it.

The filter is to be assembled in reverse order. The torque specifications (“Tightening torques” chapter) are to be observed.

Commissioning

Commission the system.

 

Notice:

There is no bleeding provided at the filter.

Assembly:

The max. operating pressure of the system must not exceed the max. adm. operating pressure of the filter (see name plate).

Before the assembly, the hole pattern of the tank must be compared to the dimensions from the "Dimensions" chapter.

As of a length of approx. 500 mm, drain pipes must be led in a bracket in order to avoid oscillations caused by the fluid flow in the tank. It is moreover to be ensured that in case of maintenance works, the filter bowl and the outlet pipe are pulled out of the filter head together.

During assembly of the filter (see also chapter “Tightening torques”), the flow direction (direction arrows) and the required servicing height of the filter element (see chapter “Dimensions”) are to be considered.

Perfect functioning is only guaranteed in the installation position filter bowl vertically downwards and ON the tank.

The maintenance indicator must be arranged in a well visible way.

Remove the plastic plugs in the filter inlet and outlet.

Ensure that the system is assembled without tension stress.

The optional electric maintenance indicator is connected via the electric switching element with 1 or 2 switching points, which is attached to the mechanical/visual maintenance indicator and held by means of the locking ring. More details see data sheet “Maintenance indicator”.

Notices:

  • Assemble and disassemble only with depressurized system! For the filter element exchange refer to “Maintenance”.
  • Tank is pressurized!
  • Do not operate the switching lever during the filter element exchange.
  • Do not exchange the optical/mechanical maintenance indicator while the filter is under pressure!
  • If the flow direction is not considered during assembly, the filter element will be destroyed. Particle contaminates could enter the system and damage the downstream components.

 

 

 

 

Information

Ordering codeOption maintenance indicatorPositionFrame size
   0040…01000160…2500
P2,2; V0,8; V1,5; V2,2Mechanical/visual maintenance indicator1
MRPressure gauge right3a
MLPressure gauge left3b
V2,2MRMechanical/visual maintenance indicator and pressure gauge right1 + 3a
V2,2MLMechanical/visual maintenance indicator and pressure gauge left1 + 3b
+ R928…Electronic switching elementSee Accessories
     
Ordering codeOption Supplementary informationPositionFrame size
FBreathing filter4
FNBreathing filter with surge protection4 + 5
MRThreaded coupling right (not possible with pressure gauge right)3a
MLThreaded coupling left (not possible with pressure gauge left)3b
NBWithout bypass valve 
R110Outlet pipe L110 mm61)
R150Outlet pipe L150 mm61)
R250Outlet pipe L250 mm61)
1)Outlet pipes for sizes 0040…0100 are preferably to be ordered pre-assembled via the complete filter. Outlet pipes for others sizes must be ordered separately and are not pre-assembled.
See “Ordering code Accessories"
optional not possible

 

 

 

 

 

 

 

 

In stock


 

10TE(N)

R92805425510TEN0040-00000A00-P2,2-M-R3
R92805521910TEN0040-00000A00-V2,2-V-U4-F
R92804037210TEN0040-G100A00-MR-V-R3
R92804036610TEN0040-G100A00-MRV2,2-M-R3
R92804000010TEN0040-G10A00-V2,2-M-R3
R92804004810TEN0040-G10A00-V2,2-M-R4
R92802566010TEN0040-G25A00-0-M-R3
R92804038410TEN0040-G25A00-MR-M-R3
R92803898010TEN0040-G25A00-MR-M-R3-F-R110
R92804039010TEN0040-G25A00-MRV2,2-M-R3
R92804944510TEN0040-G25A00-V0,8-M-R3
R92804001210TEN0040-G25A00-V2,2-M-R3
R92804015610TEN0040-G25A00-V2,2-M-R3-F
R92804025210TEN0040-G25A00-V2,2-M-R3-R110
R92804006010TEN0040-G25A00-V2,2-M-R4
R92802877310TEN0040-G40A00-0-M-R3
R92804001810TEN0040-G40A00-V2,2-M-R3
R92804006610TEN0040-G40A00-V2,2-M-R4
R92805324010TEN0040-G60A00-0-M-R4
R92805548310TEN0040-G60A00-V2,2-V-R3
R92802891510TEN0040-H10XLA00-0-M-R3
R92802807210TEN0040-H10XLA00-0-M-R4
R92805472510TEN0040-H10XLA00-0-M-U4-F
R92804048010TEN0040-H10XLA00-MR-M-R3
R92803160810TEN0040-H10XLA00-MR-M-R3-F
R92805539810TEN0040-H10XLA00-MR-M-U4
R92804048610TEN0040-H10XLA00-MRV2,2-M-R3
R92802556810TEN0040-H10XLA00-MRV2,2-M-R4-FN
R92804127110TEN0040-H10XLA00-P2,2-M-R3
R92805208610TEN0040-H10XLA00-P2,2-M-R3-R110
R92805216410TEN0040-H10XLA00-P2,2-M-R4
R92805546410TEN0040-H10XLA00-P2,2-V-R3
R92801984410TEN0040-H10XLA00-V2,2-M-R3
R92804018010TEN0040-H10XLA00-V2,2-M-R3-F
R92804022810TEN0040-H10XLA00-V2,2-M-R3-FN
R92803174610TEN0040-H10XLA00-V2,2-M-R3-R110
R92804008410TEN0040-H10XLA00-V2,2-M-R4
R92802793110TEN0040-H10XLA00-V2,2-M-R4-R110
R92804013210TEN0040-H10XLA00-V2,2-M-U4
R92803629810TEN0040-H10XLA00-V2,2-M-U4-F
R92804003910TEN0040-H10XLA00-V2,2-V-R3

Hot Products

1.0040AS20-A00-0-V, R928005849, Bosch Rexroth, Filter element, MobileHydraulics The filter element ...
10TEN0040-00000A00-P2,2-M-R3, R928054255, Bosch Rexroth, Tank mounted return line filters, 10TE(N), ...
SM12L1X/C01/19196100, R900488171, Bosch Rexroth, Open-center control block, MobileHydraulics Control ...
A1VO018DNC200/10MRVA2K310000-0, R902536353, Bosch Rexroth, A1VO series 10, Axial piston variable ...
A1VO035D4A2P0/10BLVB2S4100000-0, R902544587, Bosch Rexroth, A1VO series 10, Axial piston variable ...
A1VO035D4A2P0/10BLVB2S41000000-0, R902565136, Bosch Rexroth, A1VO series 10, Axial piston variable ...