Recommended viscosity Modular Valves Instructions for use
Normal working hours are recommended viscosity :15 - 400cSt.
If the valve back to the oil damper, the viscosity range must be
15-200cSt.
Recommended Fluids
Use any of the following hydraulic fluid
Petroleum oil: ISO VG32 or VG46 oil equivalent of oil.
Synthetic solution: phosphate ester fluid or liquid polyhydric
alcohol esters. When phosphate ester fluids, use a special fluorine
rubber seal.
Aqueous solution: the use of water - glycol solution.
Working oil temperature
Continuous working temperature of the oil is -15 - +70 ℃.
Pollution Control
Hydraulic oil pollution should be controlled, otherwise it will
cause damage or shorten the life of the valve.
Please ensure that pollution degree NAS 1638-11 level, with 25um or
more sophisticated line filter.
Assembly steps
All the stud plate screwed into the basis of the provisions, the
floor surface or pipe mounting plate screw holes.
According to the hydraulic circuit, stacked stacking valve or
solenoid valve, fitted with O-ring to the mounting surface toward
the base plate.
Superimposed valve inserted in the bolt, make sure that the empty
stack valve arrangement is correct, its modular valves at both
ends.
Screw on the nut on the bolt with specified torque tighten the nut,
after commissioning, shall be within the specified torque
re-tighten the nut,
In order to achieve a sufficient preload.
Pressure adjustment
Pressure adjustment, loosen lock nut and slowly turn the handle
clockwise as the pressure increases, the adjustment is completed do
not forget to tighten the nut.