Home Companies Jufu Water Technology Co., Ltd

Reverse Osmosis Drinking Water Treatment System Purification Machine Plant 2000L

Jufu Water Technology Co., Ltd
Active Member

Contact Us

[China] country

Address: 15F, Block B, FRD International Wealth Center, Fengcheng 12th Road, Weiyang District, Xi’an,Shaanxi, China 710018

Contact name:Chloe Cheung

Inquir Now

Jufu Water Technology Co., Ltd

Reverse Osmosis Drinking Water Treatment System Purification Machine Plant 2000L

Country/Region china
City & Province Shaanxi
Categories Water Treatment
InquireNow

Product Details

2000L RO Reverse Osmosis RO Drinking Water Treatment Purification Machine Plant Purification System
 
Product Introduction of RO Water Treatment System

We adopt different equipment to produce pure water, mineral water etc. The main equipment of RO Water Treatment Plant are silica sand filter, active carbon filter, sodium ion exchanger, hollow fiber, RO( reverse osmosis), UV sterilizer, precision filter, ozone generator, water tank etc. It can effectively get rid of muddy organic matter, iron, manganese etc, reduce the hardness of the water to make all specifications of the water quality fully meet the state fresh water standard of fresh drink water. Reverse osmosis:it is composed of reverse osmosis membrane (RO), high pressure pump and washing system to protect the reverse osmosis membrane. It can intercept substances larger than 0.0001 micron. It is the finest water filter. It can effectively intercept all dissolved salts and organic substances with molecular weight greater than 100, and allow water molecules to pass through.

 
Main Features 1. The world's most advanced Reverse Osmosis technology, optimized design and exquisite production technics. 2. All in one compact design, well-chosen materials. 3. High salt rejection rate more than 99% , 4. stable performance, safe and reliable, up to date and ingenious design, low cleaning frequency. 5. On-line conductivity monitoring, ensure good quality of water output . 6. Automatic control system; easy installation,operation and maintenance. 7. Precise design of technics and well-chosen material . 8. Long lifetime, low energy consume and low maintenance cost.
 

The Basic Working Principle of RO Water Treatment System
After a special high-pressure pump, when the raw water is added to a pressure of 6-20 kg, the raw water permeates through the reverse osmosis membrane with a pore size of only 0.0001 microns under the action of pressure. Chemical ions, bacteria, fungi, and virions cannot pass through, and are discharged with wastewater. Only water molecules and solvents with a volume of less than 0.0001 microns are allowed to pass through.
 
Technical Specifications of RO Water Treatment System

1000LPH Reverse Osmosis System
ModelJFRO-1000L
Host Size

1000x600x1600mm (can be customized)

Power2.2KW
Power Supply

220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized

Operating Pressure0.8-1.2MPa
Recovery Rate50%
Designed Water Inlet2000L/h
Outlet Flow1000L/h
Desalination Rate≥99.5%
RO FrameSUS304
Membrane Size4040
Membrane ElementsDOW /Hydranautics/Troy/ Vontron (Optional)
Number of Membranes4
Raw Water PumpCNP/NYP/GRUNDFOS (Optional)
Raw Water PumpCNP/NYP/GRUNDFOS (Optional)
Tank MaterialSS/FRP (Optional)
Control ValveManual/Automatic
Control Valve BrandFLECK/RUNXIN
Membrane HousingSS/FRP (Optional)
Pipe MaterialU-PVC, Stainless steel (Optional)

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Advantages of RO water treatment system:
Reverse osmosis equipment belongs to physical desalting method, which has many advantages.
1) Non-phase-change physical method was used to desalinate and purify the saline water under norma temperature.
2) Desalting rate of single membrane element is 99.3% and can remove colloid, organics, bacteria, virus and all kinds of heavy metals in water at the same time.
3) With water pressure as the driving force, energy consumption is the lowest among many treatment methods.
4) No need for large amount of chemical treatment, no elimination of chemical waste liquid, no environmental pollution, and the recovery rate is over 70%.
5) High automation program, automatic stop in case of ailure, with automatic protection function.
6) The system is simple, easy to operate, and the water quality is stable.
7) Equipment covers small area, compact structure, reliable operation and high water quality.
 
Process flow of RO Water Treatment System
Raw water pump→ mechanical filter(quartz sand filter)→ activated carbon filter→ Water softener filter→security filter→ high pressure pump →reverse osmosis system
1.First stage pretreatment (Sand filter)
The use of multi-medium quartz sand filters, main purpose is to remove the water contains sediment, manganese, rust, colloid material, mechanical impurities, suspended solids and other particles in the above 20UM of substances hazardous to health. The effluent turbidity is less than 0.5NTU, CODMN less than 1.5mg / L, iron content of less than 0.05mg / L, SDI less than or equal to 5. Water filter is a kind of "physical - chemical" process, the water through granular materials when isolated filter water impurities and colloidal suspensions. Filter is an effective water purification and treatment of the main process in the preparation of pure water is an indispensable process.
2. Second stage pretreatment (Carbon filter)
Activated carbon filters used to remove the pigment in the water, smell, a large number of chemical and biological organisms, reducing the residual value of water and pesticide pollution and other harmful pollutants. The structure of activated carbon filters and quartz sand filters, the difference is placed inside the strong adsorption capacity of activated carbon for removal by the quartz sand filter without the filter out organic material, adsorption of residual chlorine in the water, using water more than less than or equal to chlorine 0.1ML/M3, SDI less than or equal to 4, are strong oxidants chlorine, there are various types of membrane damage, in particular, reverse osmosis membranes are more sensitive to chlorine. In addition, the activation process, the surface of activated carbon to form non-crystalline parts of some oxygen-containing functional groups, these functional groups can have a chemical adsorption of activated carbon catalytic oxidation of bad news, to restore the performance, can effectively remove a number of metal ions in water.

3. Third stage pretreatment (Resin softener)
Cationic resin used for water softening, primarily to remove hardness of water. The hardness of water is a major calcium (Ca2 +), magnesium (Mg2 +) ion composition, when containing the raw water hardness ions through the resin layer, the water of the Ca2 +,Mg2+ was exchanged resin adsorption, and other objects at the same time the quality of the release of sodium Na + ions flow from the softener in the water is removed from the softened water hardness ions. So as to effectively prevent the reverse osmosis membrane fouling.System can automatically recoil, and so is red.
4. Fourth stage pretreatment (Micron filter)
Particle size in water to remove fine particles, sand filters can remove very small colloidal particles in the water, so that the
turbidity reached 1 degree, but still per milliliter of water for hundreds of thousands of particle size 1-5 microns colloidal
particles, the pressure on this filter to remove water after the particle size of 100 microns or less in small particles, to
further reduce the turbidity, to meet the next process of the water requirements of the protection of the next long-running
processes.
5. RO system Using reverse osmosis technology for desalination, reverse osmosis membrane was only 0.001 micron pore size, can be harmful to remove dissolved solids and bacteria, viruses, etc., desalination rate of more than 99.6 percent, in line with national standards to produce pure water, the host section contains the security filter, high-pressure pump and reverse osmosis membrane, security filters for the fourth grade and above pre-treatment systems, high-pressure pump is the host of one of the core equipment for the reverse osmosis membrane elements to provide sufficient pressure to overcome the penetration resistance to pressure and run to meet the needs of a device to achieve the rated water.
 

 
Photos of reverse osmosis water treatment system

 
 

 

 

 

 

 

 

 

 

 

 

 

FAQ:
 
1. What is the design water yield of ro membrane element? (except anti-pollution membrane and seawater desalination membrane)
 
Model 4040 is designed by 0.25m3/h
 
Model 8040 is designed by 1-1.2m3/h
 
2. What is the material of mechanical filter?
 
Carbon steel, stainless steel, fiberglass
 
3.What are the multi-way control valves?
 
Manual control valve, automatic control valve
 
Multi - way control valve is divided into: filter valve and softening valve
 
Automatic control valve is divided into: time type and flow type.
 
Multi-way control valve brands are: FLECK, AUTOTROL, Runxin, clean source, etc.

Hot Products

Ro Plant 1000lph Small Reverse Osmosis Water System Equipment For Industrial Water Treatment Product ...
1000 Lph Ro Water Plant Water System Equipment For Industrial Water Treatment Product Introduction ...
Reverse Osmosis Ro Water System Treatment Plant 1000 Lph Product Introduction of RO Water Treatment ...
Product Display Product Details Working flowchart Company profile Project showcase Customer ...
Product Display Product Details Working flowchart Company profile Project showcase Customer ...
Product Display Product Details Working flowchart Company profile Project showcase Customer ...