High Safety RO Water Treatment System With Storage Tank Water
Purifying
RO Water Treatment System Description
This system adopts mechanical and carbon filtration as pre-stage
treatment. The device removes the sediments, organic substance,
colloid, bacteria and other impurities in water. And the water can
be pre-desalted by program control system. Most of the dissolved
salt species material, bacteria and heat source can be removed by
this method. Then use ozone preservation device to make sure that
the water quality is up to the standard.
RO Water Treatment System Details
1. Capacity: 250 L / H |
2. Rated power: 3.0 KW/H |
3. Voltage: 110V / 220V / 380V, 50Hz / 60Hz, single phase / 3phase |
4. Desalting rate:>=97% |
RO Water Treatment System Performance
⇒ Main part (membrane) of reverse osmosis system is imported from
USA.
⇒ Auto stop when no water and full water.
⇒ Auto controller, RO membrane auto flush to protect membrane.
⇒ Auto start when pure water tank have no water.
⇒ Low pressure protection switch to protect high pressure pump when
there is no raw water.
⇒ High efficient and low noise high pressure pump.
⇒ Product water conductivity meter to monitor product water quality
all the time.
RO Water Treatment System Consumables
There are several kinds of consumables you need to replace
regularly. (for 250LPH)
a. Quartz sand: replaced about every 15 months. 50kg/bag,450kg/set
b. Activated carbon: replaced about every 15 months. 25kg/bag,
125kg/set
c. Resin: replaced about every 15 months. 25L/bag, 225L/set
d. PP Filter cartridge: replaced about every 1 month. 7pcs/set
e. Ro membrane: replaced about every 2 year. 8pcs/set
We suggest you buy 1- 2 years of PP filter cartridges together with
machine. Because these PP filter cartridges need to replace every
month.
RO Water Treatment System Processing
- STEP 1: AG Pre-Filtration – cartridge type, removes particulate matter
down to 20 microns.
- STEP 2: Carbon – an activated carbon cartridge filter that removes
chlorine, chloramine, solvents, lead, insecticides, gasses, and
other harmful contaminants. Works as a water softener, without the
use of salt and drawing hardness particles together and
crystallizing them. Includes an automatic backwashing system.
- STEP 3: 5 Micron Pre-Filter – removes particles, sediments, and algae.
- STEP 4: R.O. Pump – high pressure, stainless steel pump to boot water
pressure to 160 lbs. for maximum membrane efficiency.
- STEP 5: Reverse Osmosis Membrane – water is forced through a semi
permeable, .0002 micron membrane, allowing only pure water
molecules to pass.
- STEP 6: Pressure Tank – 32 gallon pressure tank assures a constant flow of
water to the filler and prolongs pump life.
- STEP 7: Post Carbon Filtration – water travels through a 4.5in x 20in
coconut shell carbon block filter, polishing it for an
exceptionally smooth taste.
- STEP 8: Ultraviolet Sterilizer – stainless steel sterilizer eliminates up
to 99.9% of all bacteria.
- STEP 9: Optional – ozone may be added to water storage tanks to prevent
future bacterial growth.
Some parts function:
1. Raw water pump: provide needed pressure for every
pre-treatment filter;
2. Quartz sand filter: use fiber glass as housing, fill quartz
sand, it can filter big particles impurities, suspended substances,
colloids etc. Important to remove iron and sediments you
mentioned;^^
3. Activated carbon filter: use fiber glass as housing, fill
activated carbon, remove color, odor, residual chlorine and
organics substances;
4. Security filter: prevent large particles, bacteria, viruses
into RO membrane, accuracy is 5µm;
5. High pressure pump: provide needed working pressure for RO
system, ensure production capacity of pure water;
6. RO system: can remove particles, colloids, organic
impurities, heavy metal ions, bacteria, virus, heat source etc.
harmful substances and 99% dissolved salts.
7. Ozone generator(for bottled drinking): can continue to kill
bacteria even water fill into bottled,viruses,cell damage,atc...
RO Water Treatment System Show