Immersion Cooling Copper Tube Aluminum Fin Fluid Air Dry Coolers

 

Why immerse?

 

  1. Silent Operations - Whether it’s single or two-phase immersion cooling, liquid cooling keeps your hardware submerged in a dielectric fluid of some type. More importantly, that will eliminates the noisy fans, which should be running throughout day and night in condition of air-based cooling and consume roughly 25-30% in additional power required to keep compute equipment on-line.
  2. Reduced PUE - Power usage effectiveness (PUE) is the ratio of a data center’s total facility energy to its total IT equipment (ITE) energy.Legacy or underside air-cooled techniques can struggle to maintain in the 1.8 to 2.4 range. Modern, purpose-built data centers have achieved significant PUE reductions using air-cooled chillers with closed-loop systems, often hitting a PUE of 1.3-1.5.With immersion cooling, PUE consistently stays under 1.3, drastically reducing a facility’s energy load.
  3. Cost Savings - Cooling accounts for a large part of operating expenses. A facility that houses thousands of servers is also expected to run 24/7, 365 days a year. In traditional air cooling, a large number of fans, HVAC and CRAC systems contribute a lot to the electricity bill. However, when servers are submerged in thermally conductive cooling solutions, electricity usage is reduced by more than 95%, which no one can refuse.

 

Dry fluid cooler features:

Air discharge direction
Performance ranges

Cooling capacity: from 5 to 649 kw

Air volume: from 2828 to 263503 m3/h

Sound pressure level: from 31 to 69 dB A(10m)

Dry coolers:customized on demand

High efficiency heat exchanger

Capacity designs for maximizing the heat transfer relative to the energy consumption of the fan.

Tube and tube coupling design for low pressure drop in the coil on the media sides(maximum 100KPa at water designing condition).

Our thermodynamic and aerodynamic designing software is long year tested and proved in Germany

Fan

Only choose low specific energy consumption fans.

Fan nozzle designs for maximum air flow and air throw.

Our fans from the world`s leading manufacturer are practically proved to be reliable in operation and long lasting.

Motor: protection class IP 54 and insulation class F.

Voltage:400V/3N/50Hz

Air separator for each fan.

TestingHeat exchangers are supplied clean and tested at a pressure of 30 bars
Options

Coil design refrigerant: water, oil, glycol.

Multiple circuits.

Sub-cooling circuits.

Stainless steel or aluminum casing.

Coated aluminum or copper fins.

Explosion ploof motor.

Customized fin spacing.


Dry fluid cooler technical parameter

Dry cooler D1 series parameter(fin space 2.1mm)

Type

D1-166-

4x630

D1-211-

6x630

D1-247-

6x630

D1-286-

8x630

D1-334-

8x630

D1-360-

10x630

D1-415-

10x630

D1-502-

12x630

D1-565-

14x630

D1-649-

16x630

CapacityWater35℃ outdoor temp.Inlet45℃,KW165.92211.36247.3286.15334.49359.72415.31502.25565.18649.48
outlet40℃Y134.59176.00200.45238.3270.889298.57335.225405.20459.3527.59
20% GlycolInlet45℃161.32205.08240.46280.05327.72351.3406.48493.40554.21638.44
outlet40℃Y130.96170.87195.07233.18265.64291.81328.48398.45450.87519.13
MediumWater flowM3/h29.003743505863728898113
Pressure dropkPa50704797959270979695
Air flowM3/h67455109723101185146293134908179502164442197326230584263503
Y512658366176900111544102528136437124680149612174710199665
Fan motorPhase3333333333
W1100165001650022000220002750027500330003850044000
Y700105001050014000140001750017500210002450028000
A20.430.630.640.840.851.0051.0061.2071.4081.60
Y12.0018.0018.0024.0024.0030.0030.0036.0042.0048.00
FanNo X φ

2X2

X630

2x3

x630

2x3

x630

2x4

x630

2x4

x630

2x5

x630

2x5

x630

2x6

x630

2x7

x630

2x8

x630

Sound pressure leveldB(A)64666667676868686969
Y10m57595960606161616262
DimensionLmm29304230423055305530683068308130943010730
Wmm2100210021002100210021002100210021002100
Hmm1070107010701070107011201120112011201120
Amm--------------------
Bmm1340134013401340134013401340134013401340
Cmm1300130013001300130013001300130013001300
Dmm640640640640640640640640640640
Inlet φmm3”3”3”DN100DN100DN100DN125DN125

2X

DN125

2X

DN125

Inlet φmm3”3”3”DN100DN100DN100DN125DN125

2X

DN125

2X

DN125

Product weight(empty)kg6586897601105127013201420158418482112

Shenglin dry fluid cooler selection software example:


Packing:

 

Hot Products

Rooftop Fresh High Efficiency Duct Type Rooftop Air Conditioner For Whole Sales Capacity: 120~300kw, ...
High Safety Level Standard Rooftop HVAC Units Heat Recovery Type Rooftop Package Units​ Description: ...
R410a Rooftop Package Central Air Conditioner Rooftop Freezer Units Description: 1. Cooling capacity...
CE Approved Central Air Conditioner System Roof Mounted Ac Package Unit Main Features A. Efficient ...
Rooftop Package Unit Roof Top Air Conditioner Central Air Conditioning Boats Rooftop Aircon HVAC ...
Data Center Servers Liquid Submersion Cooling System Dry Air Coolers What's Immersion Cooling? Also ...