T3 Working Condition Rooftop Ac Unit With Anti-corrosion Treatment Frame

 

Description:
 

1. Rooftop air conditioner generally have many functions such as refrigeration,heating,air supply,easy to use,low cost installation, low maintenance cost, widely used in air conditioning engineering project.

 

2. Rooftop air conditioner,saving the cooling tower and cooling water pump cost for customers, is particularly suitable for water shortage area.It does not need special room for installation, and can be installed on the roof or building ground outside

 

3. package unit heat pump is widely used in large space of centralized air treatment, such as convention and exhibition center,stadiums, theatres, shopping malls, supermarkets, waiting room, conference room, production workshop, library,etc.

 

4. It is equipped with high performance compressor,low noise axial flow fan, high precision grades of electronic expansion valve,and advanced control system.

 

Structure:
 
1. Frame: channel steel sandblasting, then primer, then topcoat (sometimes primer and topcoat are also brushed with 2 coats), bolts SS304.
 
2. Epoxy aluminum fin heat exchangers.
 
3. Can be used under T3 working conditions and can withstand an environment of up to 55°c (for 2 reasons):
 
A. Parallel compressors (can be stopped when the ambient temperature is high, and one compressor can be stopped when the ambient temperature is the highest.

B. All fans are EC frequency conversion, stepless speed regulation (continuous speed regulation).
 
Technical paramater:
ModelSRF12ZASRF 15ZASRF18ZASRF24ZASRF30ZASRF35ZA
SF12ZASF15ZASF18ZASF24ZASF30ZASF35ZA
Nominal cooling capacitykW1215.217.52430.335.6
Nominal heating capacitykW13.216.618.426.533.337.7
Energy regulation%0,100%0,50,100%
Power supply380V / 3Ph / 50HZA
Cooling input capacitykW4.15.35.58.811.312.3
Heating input capacitykW3.84.85.18.210.411.3
Start currentA486263637476
Cooling running currentA7.49.710.216.121.223.3
Heating running currentA6.99.29.715.120.122.2
Throttling methodThermal expansion valve
Cooling system111122
RefrigerantR410A
CompressorTypeHermetic scroll compressor
Qty111122
Condensation side 
CondenserTypeCopper tube and aluminum fin
Qty111111
Drive typeDirect drive
Motor powerkW0.250.370.370.550.750.75
Air volumem3 /h46007800780090001260012600
Evaporation side 
EvaporatorTypeCopper tube and aluminum fin
Qty111111
Motor powerkW0.320.370.451.11.52.2
Air volumem3 /h210026003400410052006300
Drive typeDirect drivePulley
Static pressure(Pa)100100100200200250
FilterAluminum filter G3
Noise dB(A)676768717272
Refrigerant filling volume(kg)3.13.14.32x3.12x3.12x4.3
Overall dimensionsLength(mm)mm141014101410197819781978
Width(mm)mm110011001100117511751175
Height(mm)mm109510951095109510951095
Weightkg240260290420480500
 
Note: 1. Nominal cooling capacity is under nominal air volume, indoor DB/WB temperature is 27℃/19℃ and outdoor DB/WB temperature is 35℃/24℃ condition;
2. Nominal heating capacity is under nominal air volume, indoor DB/WB temperature is 20℃/15℃ and outdoor DB/WB temperature is 7℃/6℃ condition;

 

Application:

Residential, office building, shopping mall...

 

Reference:

Country: Turkey
Application:distributor
Type: heat pump type
Cooling capacity: 108.9KW;
Heating capacity: 113KW;
380V-3Ph-50hz
R410a
ESP: 350 Pa; 19940 m3/h
25% fresh air;
Country: Nigeria
Application: Pharmaceutical Factory
Type: heat pump type
Cooling capacity: 36.2kW
Heating capacity: 82kW
Refrigerant: R407C
Compressor: Sanyo
 
Country: Jordan
Application: Textile Factory
Type: heat pipe heat recovery type
Cooling capacity: 368kW
Heating capacity: 359kW
Refrigerant: R410A
Compressor: Copeland
With heat recovery coil
Country: USA
Application: Residential
Type: heat pump type
Cooling capacity: 5 Ton
Heating capacity:
Refrigerant: R410A
Compressor:
COP: 3.0
Power supply: 230V/3PH/60Hz

 

 

 
Country:UAE
Application:offshore Drilling Platform
Cooling capacity: 80kw
Supply air volume: 4000×2 m3/h
Condensing fan: 12000m3/h
Refrigerant: R407C
Power supply:430V-3Ph-60Hz
Evaporator & condenser type: copper tube epoxy aluminum fin
Country:Australia
Application:hall
Cooling capacity: 128kw
Heating capacity: 135kw
Capacity regulator: 0,25,50,75,100
Power supply: 415V/3PH/50hz
Refrigerant:R410A
Country:China
Application: Amusement park
Cooling capacity: 180kw
Heating capacity: 192.5kw
Supply air volume: 32000m3/h
ESP: 550pa
Power supply: 380V/3PH/50hz
Refrigerant:R22
Country: Philippines
Application: Factory
Type: Fresh air type
Cooling capacity:21.9kw
Heating capacity:25kw
Supply air volume: 3000m3/h
Electric heating: 6kw
Power supply:220v/3PH/60hz
10% fresh air
Refrigerant:R410A

 

 

 

 
Country: China
Application: Rolling bearing manufacturer
Type: wheel heat recovery type
One model:
Cooling capacity: 95kw
Condensation and heating capacity: 55kw
Supply air volume: 19000m3/h
Exhaust air volume: 19000m3/h
Another model:
Cooling capacity: 210kw
Heating capacity: 215kw
Supply air volume: 38000m3/h
Exhaust air volume: 38000m3/h
Country: China
Application:Flight simulation system laboratory
Cooling capacity:10kw
Supply air volume:3000m3/h
Power supply: 380V/3PH/50Hz
 
Country: China
Application:Ferry waiting hall
Type: heat pump type
Cooling capacity:182.5kw
Supply air volume: 22000m3/h
 
Country: China
Application: Cool Storehouse
Type: constant temperature and constant humidity unit
One model:
Cooling capacity: 22kW
Electric heating capacity: 82kW
Humidifying capacity: 6kg/h
Supply air: 4500 m3/h
Another model:
Cooling capacity: 180kW
Electric heating capacity: 90kW
Humidifying capacity: 30kg/h
Supply air: 35000 m3/h

 

 

 

 

After-Sales Service:
1. If the project needs our installation guidance, we can send our engineer and translator, but not free. We can also send customers installation video to teach them how to fix and operate with our product.

2. Usually, our product warranty is 18 months after leaving factory or 12 months after installation. within this months, all parts broken will be responsible for our factory.

 

Hot Products

R407C -5 ℃ Single Compressor Water Cooled Water Chiller Products Features World famous brand screw ...
CE Certification Rooftop HVAC Unit For Shopping Mall Air Conditioning System Description: 1. Air ...
Rooftop Fresh High Efficiency Duct Type Rooftop Air Conditioner For Whole Sales Capacity: 120~300kw, ...
High Safety Level Standard Rooftop HVAC Units Heat Recovery Type Rooftop Package Units​ Description: ...
R410a Rooftop Package Central Air Conditioner Rooftop Freezer Units Description: 1. Cooling capacity...
CE Approved Central Air Conditioner System Roof Mounted Ac Package Unit Main Features A. Efficient ...