Home Companies Shenzhen Meigaolan Electronic Instrument Co. Ltd

20Hz-26.5GHz RS Spectrum Analyzer , Rohde & Schwarz FSQ26 Signal Analyzer

Shenzhen Meigaolan Electronic Instrument Co. Ltd

Contact Us

[China] country

Trade Verify

Address: RA1-B2,F32 of Dongjianghaoyuan, Baomin Rd, Bao'an District, Shenzhen,China

Contact name:Dannie

Inquir Now

Shenzhen Meigaolan Electronic Instrument Co. Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

20Hz-26.5GHz RS Spectrum Analyzer , Rohde & Schwarz FSQ26 Signal Analyzer

Country/Region china
City & Province shenzhen
Categories Radio & TV Broadcasting Equipment
InquireNow

Product Details

Rohde & Schwarz FSQ26 signal analyzer 20Hz-26.5GHz RS spectrum analyzer spot

 

Description of Rohde and Schwarz FSQ26 signal analyzer

 

Description
Key Facts The Signal Analyzer R&S FSQ combines two instruments in one. It offers signal analysis at a demodulation bandwidth of up to 120 MHz with the dynamic range of a high-end spectrum analyzer. Features
  • Frequency range: 20 Hz to 3.6 GHz, 8GHz, 26,5GHz and 40 GHz
  • Dynamic range of a high-end spectrum analyzer
  • TOI + 25 dBm, typ.
  • 1 dB compression +13 dBm, typ.
  • 84 dB ACLR/3GPP with noise correction
  • 28 MHz demodulation bandwidth (optional 120 MHz)
  • 16 Msample I and Q memory
  • Application firmware for digital demodulation measurement
  • Bluetooth
  • GSM/EDGE
  • 3 GPP WCDMA, HSDPA, TD-SCDMA
  • CDMA2000, 1xEV-DV, 1xEV-DO
  • WLAN 802.11a/b/g/j
  • WiMax IEEE 802.16-2004,802.16e
  • General purpose vector signal
List of Options
B10External generator control for FSP, FSU, FSG, FSQ, ESU, ESCI, ESPI and for retrofit of
B100I/Q memory extension 235 Msamples Extendable up to 705 Msamples (Not retrofittable, excludes FSP-B10)
B102I/Q memory extension Extends FSQ-B100 to 705 Msamples (FSQ-B100 required)
B12Output attenuator for tracking generator for FSU, FSQ
B16LAN Interface
B17Digital Baseband Interface Not retrofittable
B18Removable Hard Disk (not retrofittable)
B19Second Hard Disk for FSQ-B18 (for FSQ-B18, variant 1303.0400.03)
B21LO/ZF connections for external mixers (for FSQ26, FSQ40,FSU26, FSU43, FSU46, FSU50)
B23Preamplifier 20 dB to FSQ26, 3.6 GHz - 26.5 GHz (not retrofittable, requires FSU-B25)
B24Preamplifier 30dB, 100 kHz to 50GHz (for FSMR26/43/50, FSQ26/40, FSU26/43/46/50;
B25Electronic attenuator 0 to 30 dB, Preamplifier 20 dB, 10MHz - 3.6 GHz for FSU, FSQ
B28Trigger port for FSP,FSQ,FSU; for indication of trigger conditions
B33Disabled USB ports excludes FS-K9
B4OCXO 10 MHz aging/year: 0.35*10E-7 for FSU, FSQ, FSMR
B5Output for low phase noise 640MHz reference signal for FSU3, FSU8, FSQ3 und FSQ8
B71Analogue base band inputs 50 Ohm/1M Ohm input impedance information bandwidth 36 MHz
B72Bandwidth extension for IQ-Demodulation and Vectorsignalanalysis 120MHz IQ bandwidth.
B88RF hardware option 1 FSQ26
B9Tracking generator for FSU and FSQ, 100 kHz - 3.6 GHz
C3Three years of depot calibration coverage based on the R&S recommended calibration interval - includes test data. The first calibration is included with product delivery with 2 additional depot calibration(s).
C5Five years of calibration coverage based on the R&S recommended calibration interval - includes test data. The first calibration is included with product delivery with 4 additional depot calibration(s).
DCV-2Documentation of calibration values
DCV-ZPPrintout of DCV (additional, in combination with DCV-Option only)
DKDFSQ26 DKD (ISO17025) calibration incl. ISO 9000 calibration (order only with device)
EX-IQ-BOXDigital I/O adapter module for AFQ, AMU, FMU, FSG, FSQ, SMJ, SMU (AFQ-B18, AMU-B17, AMU-B18, FSQ-B17,
FS-B33USB mass memory write protection, disables writing to USB memory sticks (ex factory only)
FS-K10GSM/EDGE/EDGE Evolution Measurement Appl (for FSG/FSQ/FSU)
FS-K110Analysis of TETRA II / TEDS signals (for FSQ, FSU with option FSU-B73)
FS-K15VOR/ILS measurements for FSMR
FS-K40Application firmware for phase noise measurements for FSMR, FSP, FSQ, FSU
FS-K5Application firmware GSM/EDGE tests for FSP, FSU, FSQ
FS-K5UUpgrade of FS-K5 to FS-K10, GSM/EDGE/EDGE Evolution Measurement Appl (for FSG, FSQ, FSU)
FS-K7FM demodulator, allows measurement of FM specific parameters (for FMU, FSP, FSU)
FS-K72Application firmware 3GPP-FDD BTS transmitter test for FSMR, FSP, FSU, FSQ
FS-K73Application firmware 3GPP-FDD UE transmitter test for FSMR, FSP, FSU, FSQ
FS-K73+3GPP HSPA+ UE transmitter test, application firmware (for FSMR, FSP, FSQ, FSU, FSUP,
FS-K743GPP HSDPA base station test application firmware for FSMR, FSU, FSP, FSQ
FS-K74+3GPP HSPA plus, base station test. Application firmware (for FSP, FSQ, FSU, FSG;
FS-K763GPP TD-SCDMA base station test; application firmware for FSMR, FSP, FSQ, FSU
FS-K773GPP TD-SCDMA mobile station test; application firmware for FSMR, FSP, FSQ, FSU
FS-K8Application firmware for Bluetooth measurement on FSP, FSU and FSQ
FS-K82CDMA2000/1xEV-DV base station test application firmware for FSMR, FSP, FSU, FSQ
FS-K83CDMA2000/1xEV-DV mobile station application firmware for FSMR, FSP, FSQ, FSU
FS-K841xEV-DO base station test application firmware for FSMR, FSU, FSP, FSQ
FS-K851xEV-DO mobile station test application firmware for FSMR, FSP, FSQ, FSU
FS-K9Measurements with NRP power sensors NRPZ11/Z21/Z22/Z23/Z24/Z51/Z55/Z91 requires NRP-Z3 or NRP-Z4
FSP-B10External generator control for FSP, FSU, FSG, FSQ, ESU, ESCI, ESPI and for retrofit of
FSP-B28Trigger port for FSP,FSQ,FSU; for indication of trigger conditions
FSU-B12Output attenuator for tracking generator for FSU, FSQ
FSU-B21LO/ZF connections for external mixers (for FSQ26, FSQ40,FSU26, FSU43, FSU46, FSU50)
FSU-B24Preamplifier 30dB, 100 kHz to 50GHz (for FSMR26/43/50, FSQ26/40, FSU26/43/46/50;
FSU-B25Electronic attenuator 0 to 30 dB, Preamplifier 20 dB, 10MHz - 3.6 GHz for FSU, FSQ
FSU-B4OCXO 10 MHz aging/year: 0.35*10E-7 for FSU, FSQ, FSMR
FSU-B5Output for low phase noise 640MHz reference signal for FSU3, FSU8, FSQ3 und FSQ8
FSU-B9Tracking generator for FSU and FSQ, 100 kHz - 3.6 GHz
K100EUTRA/LTE downlink, application firmware
K101EUTRA/LTE uplink, application firmware
K102EUTRA/LTE Downlink, MIMO. PC software for FSG and FSQ (FSQ-K100 required)
K104Analysis of EUTRA/LTE TDD downlink signals (for FSG, FSQ)
K105Analysis of EUTRA/LTE TDD uplink signals (for FSG, FSQ)
K3Noise Figure Measurement Software
K30Application firmware for noise figure and gain measurements for FSMR, FSP, FSQ, FSU
K30Application firmware for noise figure and gain measurements for FSMR, FSP, FSQ, FSU
K4PHASE NOISE
K40Application firmware for phase noise measurements for FSMR, FSP, FSQ, FSU
K5Application firmware GSM/EDGE tests for FSP, FSU, FSQ
K7FM demodulator, allows measurement of FM specific parameters (for FMU, FSP, FSU)
K70Vector signal analysis for FSQ; 28 MHz demodulator-BW FSK, MSK, PSK,
K72Application firmware 3GPP-FDD BTS transmitter test for FSMR, FSP, FSU, FSQ
K73Application firmware 3GPP-FDD UE transmitter test for FSMR, FSP, FSU, FSQ
K73+3GPP HSPA+ UE Application Firmware
K743GPP HSDPA base station test application firmware for FSMR, FSU, FSP, FSQ
K74+3GPP HSPA plus, base station test
K763GPP TD-SCDMA base station test; application firmware for FSMR, FSP, FSQ, FSU
K773GPP TD-SCDMA mobile station test; application firmware for FSMR, FSP, FSQ, FSU
K8Application firmware for Bluetooth measurement on FSP, FSU and FSQ
K82CDMA2000/1xEV-DV base station test application firmware for FSMR, FSP, FSU, FSQ
K83CDMA2000/1xEV-DV mobile station application firmware for FSMR, FSP, FSQ, FSU
K841xEV-DO base station test application firmware for FSMR, FSU, FSP, FSQ
K851xEV-DO mobile station test application firmware for FSMR, FSP, FSQ, FSU
K9Measurements with NRP power sensors NRP-Z11/Z21/Z22/Z23/Z24/Z51/Z55/Z91 requires NRP-Z3 or NRP-Z4
K90Application firmware WLAN 802.11A TX tests (EMV, flatness, mask) for FSQ
K90UUpgrade from FSQ-K90 to FSQ-K91, 802.11A,B,G,J TX tests requires 512 MB memory
K91Application firmware WLAN 802.11A,B,G,J TX tests requires 512 MB memory
K91ACUpgrade of FSQ-K91 to 802.11ac
K91NUpgrade of FSQ-K91 to 802.11n
K92Application firmware WIMAX (802.16-2004) TX measurements
K92UUpgrade of FSQ-K92 to FSQ-K93
K93Application firmware for WIMAX IEEE 802.16e, WIBRO
K94Application firmware for WIMAX IEEE 802.16e-2005 MIMO
K96Generic OFDM measurement demodulator. Selectable pilot and data carriers and modulation type
Q3-DKDISO 9000 Calibration / data
R3Three years of depot repair coverage, including recalibration and test data if necessary to complete the repair. First year of repair coverage is provided by the 12-month new product warranty.
R5Five years of depot repair coverage, including re-calibration if necessary to complete the repair. First year of repair coverage is provided by the 12-month new product warranty.
U2WINDOWS XP UPGRADE
U3CPU board upgrade and 1.5GB memory extension for FSQ without flash drive FSQ-B18
Z110External Harmonic Mixer 90 - 110 GHz
Z2Compact Keyboard with Trackball
Z4DC Block 10 KHz - 18 GHz N Connector 50 Ohm, 50 VDC
Z52.4 mm Test Port Adapter
Z60External Harmonic Mixer 40 - 60 GHz
Z75External Harmonic Mixer 50 - 75 GHz
Z90External Harmonic Mixer 60 - 90 GHz
ZZA-41119" adapter, 4 HU, 1/1 for BW2000 cabinets

 

FAQ:
1.Can you ship order to Canada or Australia ?
Yes,we can .We send orders worldwide .
2. What delivery method do you use ? and delivery time ?
We can ship by EMS,DHL,FedEx,UPS,TNT with tracking number. Usual delivery time is 4-7 workdays.
3. What is your payment term?
100% T/T payment before shipment.
4. How can I ask any other question ?
You can contact us online or leave us messages below .

 

 

Hot Products

​​Keysight Agilent N4433A 4-port RF Electronic Calibration ECal Module Description of Keysight ...
Fluke 435 Power Quality Analyzers 3-Phase, 1000 Vrms, 200 kS/s, Class A Compliant, 16 MB Memory ...
Keysight (Agilent) E4990A Impedance Analyzer, 20Hz to 10/20/30/50/120 MHZ Description The E4990A ...
Kikusui TOS9300 AC Hipot Tester with Insulation Resistance Test, 5 kV Description: The TOS9200 ...
Keysight (Agilent) 34970A Data Acquisition / Data Logger Switch Unit Description The Agilent 34970A ...
Keysight (Agilent) L4445A Microwave Switch/Attenuator Driver Description The Agilent L4445A provides ...