Residential Battery Energy Storage 12V150Ah , 150 A Discharge , Series Connection

 

  • 1. operate voltage range: 10~14.6V;
  • 2. continuous charge current: ≤150A;
  • 3. continuous discharge current: ≤150~200A;
  • 4. pulse discharge current(3S): ≤500A;
  • 5. short protection: 750A~1000A(150~500us);
  • 6. Bluetooth or WIFI connection optional;
  • 7. max. 4groups in series optional;
  • 8. recommend max. 4 groups in parallel;
  • 9. compatible with most inverters including Schneider SW series inverter, XW+ inverter, Magnum inverter, the Outback Radian inverter, SMA inverter, Victron inverter, etc

 

1. General Information

 

This specification defines the performance of rechargeable LiFePO4 battery pack TB-BL12150F-SC-S110A manufactured by SHENZHEN TOPBAND BATTERY CO., LTD, describes the type, performance, technical characteristics, warning and caution of the battery pack. The battery pack supports Bluetooth communication function. Through Android and IOS APP, it can read the battery status and information. Especially due to the Android system’s openness, different smartphone manufacturer will have their own different Bluetooth hardware version and customized feature Android systems. So the APP may not work well on some smartphones (with Android system) due to the compatible issue. It is necessary for the customer to confirm whether the phone is compatible with the APP.

 

2. Specification(@Battery initial Temp25±5℃)

NO.ItemsCriteriaRemarks
2.1Rated Capacity150Ah 
Minimum Capacity147Ah 
2.2Energy1.92KWh 
2.3Nominal Voltage12.8V 
2.4Outgoing Voltage≥12.8V 
2.5Internal resistance≤20mΩ 
2.6Charge voltage14.6±0.2V 
2.7Floating charge voltage13.8±0.2V 
2.8Standard charge current100A 
2.9Maximum charge current150A 
2.10Maximum discharge current150A 
2.11Pulse discharge current500A/Continuous for 3s 
2.12Discharge cut-off voltage10.0~11.0V 
2.13Series parallel applicationMax. 4 groups in series 
2.14Precharge to capacitive loadAvailableSmooth the start current and no spark when connect to load
2.15DimensionLength: 485±2mm 
Width: 170±2mm 
Height: 240±2mm 
2.16WeightApprox: 20.2±0.5Kg 

 

2.17

Operating TemperatureCharging:0~45℃
Discharging:-20~60℃
Recommended operating temperature:15℃~35℃
2.18Self-discharge rateResidual capacity:≤2%/month;≤12%/year
2.19Storage Temperature & Humidity RangeLess than 1 month:-20℃~45℃,45%RH~75%RH
Less than 3 months:-10℃~35℃,45%RH~75%RH

Recommended storage environment:

15℃~35℃,45%RH~75%RH

Longtime storage:

If the battery need be stored for a long time, the voltage should be13.2V (50%SOC), and stored in the condition as storage proposal. It needs at least one charge & discharge cycle every six months.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3. Test Conditions

3.1 Standard Test Conditions

3.1.1 Unless otherwise specified, all performance tests are required conducted at temperature 25℃±2℃, Humidity less than 45%~75%RH.

3.1.2 Unless otherwise specified, the tested product is required unused within two months after outgoing.

3.2 Standard Charge Mode

"Standard Charge" means at 25±2℃ charge to limit voltage with 0.33C constant current, then charge with constant voltage until current less than 0.02C.

3.3 Quick Charge Mode

"Quick Charge" means at 25±2℃ charge to limit voltage with 1.0C constant current, then charge with constant voltage until current less than 0.02C.

3.4 Standard Discharge Mode

"Standard Discharge" means at 25±2℃ discharge to the cut-off voltage with0.33C current.

3.5 Quick Discharge Mode

"Quick Discharge" means discharging to the cut-off voltage with 1.0C current.

 

4. Product Performance

NO.ItemsCriteriaTesting method
4.1Rated Capacity150AhRest for 1 hour after fully charged, then discharge with 0.5C current until the battery reaches the discharge cutoff voltage. Repeat above process for three times, if the discharge time is not less than 120 minutes, you can stop and define the Discharging current*time value (Ah) as battery capacity.
4.2Minimum Capacity147Ah
4.3Internal resistance≤20mΩ50% battery SOC state frequency of 1 KHZ ac resistance tester
4.5

Cycle life

(DOD100%)

≥2000cycleDischarge with the current of 0.33C until it can’t discharge, and then rest it for 1h. Charge the battery following CC (0.33C)/CV (14.6V) mode to full capacity, and then rest it for 1h. Repeat above process until full charged capacity is no more than 80% of normal value. Accumulated times is defined as cycle life.
4.6

Discharge Temperature

Characteristics

-20℃≥70%At 25±5℃ discharge the battery with the current of 0.5C to the cut-off voltage and record charge capacity. Store the battery at various temperatures for 2h and discharge the battery with 0.5C to the cut-off voltage.
-0℃≥80%
25℃≥100%
55℃≥95%
4.7Charge Retention ability

Residual

capacity≥80%

Charge the battery to full capacity and store it for 28days, and then discharge it with 0.5C to the cut-off voltage.
Recovery capacity≥90%
4.8Bluetooth communicationThrough APP, user can read the battery system information such as voltage, current, SOC, temperature, etc.
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5. Protective circuit specification

The batteries are supplied with a LiFePO4 Battery Management System (BMS) that can monitor and optimize every single prismatic cell during charge & discharge, to protect the battery pack overcharge, over discharge, short circuit. Overall, the BMS helps to ensure safe and accurate running.

 

NO.ItemsContentSpecification
5.1OverchargeOver-charge protection for each cell3.80±0.05V
Over-charge release for each cell3.60±0.05V
Over-charge release methodUnder the release voltage
5.2Over dischargeOver-discharge protection for each cell2.50±0.05V
Over-discharge release for each cell2.80±0.05V
Over-discharge release methodCharging recovery
5.3OvercurrentDischarge over current protection 1255±5A, delay 4~6min
Discharge over current protection 2400±20A, delay 5~6s
Overcurrent release method8s after cut off the load.
5.4ShortDo not short-circuit the electrodesDesigned For 800A~1000A /150-500us
5.5Battery temperatureCharge over temperatureProtection @65±5℃
Release @50±5℃
Discharge over temperatureProtection @65±5℃
Release @50±5℃
5.6Static powerNormal static power consumption≤20mA; After discharge protection≤600uA
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6. Dimensional Drawing (Unit: mm)

 

7. Transportation

* Based on the character of cell, proper environment for transportation of LiFePO4 battery pack need to be created to protect the battery.

* Battery should stay in the warehouse 15℃~35℃ where is dry, clean, shade, and well-ventilated.

* The battery should be stored in 50% SOC during transportation.

* The battery needs to be charged every 6 months if out of use

* Keep the battery against dropping, turning over and serious stacking during loading.

 

8. Warning & Tips

Please read and follow the specification and caution remarks on battery surface before using the battery. Improper use may cause heat, fire, rupture, and damage or capacity deterioration of the battery. SHENZHEN TOPBAND BATTERY CO., LTD. Describes is not responsible for any accidents caused by the usage without following our specification.

² The battery must be far away from heat source, high voltage, and avoid to be exposed in sunshine for long time.

² Never throw the battery into water.

² Do not put the battery in a charger or equipment with wrong terminals connected.

² Never connect the positive and negative of battery with metal.

² Avoid excessive physical shock or vibration. don't hit, fall, stamp on the battery

² Without the permission of the manufacturer and guidance, forbidden to remove or to assemble the battery

² Do not use the battery mixed with another different manufacturer, type, or model batteries.

² Keep the battery against high temperature. Otherwise, it will cause battery heat, get into fire or lose some function and reduce the life.

² When battery run out of power, please charge your battery timely (≤15day).

² Please use the matched or suggested charger for this battery.

² If battery emits a peculiar smell, heating, distortion or appears any abnormity during working or storage, please stop using and take it out from the device.

² If the battery leaks and get into the eyes or skin, do not wipe, instead, rinse it with clean water and see doctor immediately.

² Please far away from children or pets.

² Do not put disuse battery into a fire or water.

² It supports max. 4groups in series connection.

² Parallel connection of this battery pack is allowed under the condition that voltage difference ≤0.2V, parallel numbers ≤4 groups, and operated by professionals.

 

9. Battery operation instruction

Charge and discharge

1. Charging current: Do not surpass the largest charging current that specification stipulated.

2. Charging voltage: Do not surpass the highest limited voltage that specification stipulated.

3. Charging temperature: Within temperature scope that specification stipulated.

4. Charge with constant current, then with the constant voltage, no reverse charge, which is dangerous1

5. Special note: Short time doesn't affect the use of the battery overcharge too, but for a long period of time over discharge or over charge can affect the function of the battery failure, or the battery can't use permanent, appear serious safety hazards, and need longtime floating please use the recommended floating model specification. Battery when not in use for a long time, because of its own self-discharge characteristics can also cause discharge, to prevent the occurrence of a discharge, the battery should maintain a certain capacity; maintain the voltage at 50% state of SOC.

 

10. Other Chemical Reaction

Because batteries utilize a chemical reaction, battery performance will deteriorate over time even if stored for a long period of time without being used. In addition, if the various usage conditions such as charge, discharge, ambient temperature, etc. are not maintained within the specified ranges, the life expectancy of the battery may be shortened or the device in which the battery is used may be damaged by electrolyte leakage. If the discharge time is much shorter than the normal after fully charged, even battery is charged correctly, and this may indicate it is time to change the battery.

 

Hot Products

Low Self-discharge 3.2V50Ah Rechargeable Lifepo4 Battery with 2 Years Warranty and TUV/ UN38.3 1. ...
3.2V100Ah Rechargeable Lifepo4 Battery Cell Long warranty Low self - discharge rate 1. About us ...
Prismatic Lifepo4 Battery Cells Low Self - Discharge 3.2V 12Ah 20Ah 25Ah 50Ah · long life & deep ...
3.2V Rechargeable Lifepo4 Battery , Super Life Time LFP Battery Cells long life & deep cycle( over ...
Rechargeable 3.2V 25Ah Lifepo4 Prismatic Battery Cell with 8 years calendar life Lead acide battery ...
3.2V 50Ah Rechargeable Lifepo4 Battery Cells with low Self Discharge rate 1. General This product ...