Home Companies Xi 'an West Control Internet Of Things Technology Co., Ltd.

NYLD 4-20mA Intelligent Electromagnetic Flow Meter 0.1 - 10m/S High Precision

Xi 'an West Control Internet Of Things Technology Co., Ltd.

Contact Us

[China] country

Trade Verify

Address: Block V5, Ronghao Industrial Town, Gaoling District, Xi'an City, Shaanxi Province

Contact name:Gao

Inquir Now

Xi 'an West Control Internet Of Things Technology Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

NYLD 4-20mA Intelligent Electromagnetic Flow Meter 0.1 - 10m/S High Precision

Country/Region china
City & Province Shaanxi
Categories Camera Chargers
InquireNow

Product Details

NYLD 4-20mA Intelligent Electromagnetic Flow Meter 0.1-10m/S High Precision

 

 

NYLD Intelligent Eletromagnetic Flowmeter

 

The NYLD intelligent type electromagnetic flowmeter consists of a sensor and a converter. It is based on Faraday's law of electromagnetic induction, which is used to measure the volume flow of conductive liquid with conductivity greater than 5μs/cm. It is an inductive meter for measuring the volume flow of conductive medium. In addition to measuring the volume flow of general conductive liquid, it can also be used to measure the volume flow of strong corrosive liquids such as strong acid and alkali and uniform liquid-solid two-phase suspension liquid such as slurry, pulp and paper pulp. It is wdely used for flow measurement of petroleum, chemical, metallurgy, textile, papermaking, environmental protection, food and other industrial sectors and municipal management, water conservancy construction, rivers and other fields.

 

NYLD Intelligent Eletromagnetic Flowmeter Technical Parameters

 

Standard Nominal

diameter (mm) (Special specifications can be customized)

JB/T 9248-2015

pipe type PTFE lining: DN10~DN600; pipe type rubber lining ink:

DN40~DN2200

Plug-in type: DN150~DN3000

Flow directionPositive and negative
Range ratio20:1
Repeatability error±0.1% of the measured value
Accuracy grade

pipe type: 0.5 grade, 1.0 grade;

Plug-in: 1.5 grade, 2.0 grade

Measured medium temperature

Normal rubber lining: -20~+60°C

High temperature rubber lining: -20~+90°C

PTFE lining: -30~+100°C

High temperature tetrafluoro lining: -20~+180°C

Rated operating pressure

(high pressure can be customized)

 

DN10-DN150: ≤1.6MPa

DN200-DN350: ≤1.0MPa

DN400-DN1000: ≤0.6MPa

DN450-DN2200: ≤0.25MPa

Flow rate range0.1-10m/s
Conductivity rangeThe conductivity ofthe measured fluid is ≥5μs/cm
Signal output4-20mA (load resistance 0~750Ώ), pulse/frequency, control level
Communication output

Rs485 communication MODBUS protocol, HART communication interface

Power supply220VAC or 24VDC

Required straight

pipe length

Upstream ≥5DN

downstream ≥2DN

Connection modeThe flowmeter and the pipe use flange connection, and the flange meets the national standard: GB/T9115.1-200
Explosion-proof gradeExdllСT6
Protection gradeIp65, it can be customized up to IP68
Ambient Temperature-25~+60℃
Ambient humidity5%~95%
Total power consumptionLess than 20W

 

NYLD Intelligent Eletromagnetic Flowmeter Operating Principle

 

According to the principle of Faradayelectromagnetic induction, a pair of detecting electrodes are mountedon the wall of the pipe perpendicular to the axis of the measuring pipe and the magnetic line of force.Whenthe conductive liquid moves along the axis of the measuring pipe, theconductive liquid cuts the magnetic line of force to generate an induced potential.The induced potential is detected by the two detection electrodes and the value is proportional to the flow rate.Thevalue is:

E=KBVD Where: E- induced potential;
K-thefactor related to the magnetic field distribution and the axial length;
B-magnetic induction intensity;
V-conductive liquid average flow rate;
D-electrode spacing; (measure inner diameter of the pipe)

 

The sensor transmits the induced potential Eas a flow signal to the converter.After a series of digital processing such as amplification and conversion filtering, the instantaneous flow rate and the accumulated flow rate are displayed by the dot matrix liquid crystal with backlight.The converter has4-20mA output, alarm output and frequency output, and has RS-485 communication interface, and supports HARTand MODBUS
protocols.

 

NYLD Intelligent Eletromagnetic Flowmeter Design Features

 

■ Full digital processing, strong anti-interference ability, reliable measurement, high precision, flow measurement range can reach 150:1;
■ Ultra-low EMIswitching power supply, large voltage range of suitable power supply, goodanti-EMI performance;
■Use 16-bitembedded microprocessor, with fast operation speed, high precision, and programmable low-frequency rectangular wave excitation,improving the stability of flow measurement and low power consumption;
■ Use SMD parts and surface mount (SMT) technology, high circuit reliability;
■ No moving parts in the pipe, no flow blocking parts, and there is almost no additional pressure loss in the measurement;
■ Itcan modify the range online on site according to the actual needs of users;
■The measurement results are independent of the physical parameters such as flow velocity distribution, fluid pressure, temperature, density, viscosity;
■ High-definition backlit LCDdisplay, fullChinese menuoperation, easy to use, easy to operate, easy to learn and understand;
■ Withdigital communication signal output such as RS485, RS232, Hartand Modbus (optional);
■ With self-test and self-diagnosis function;
■ With hourly total recording function, recording the total amount of flow in hours, suitable for time-sharing measurement (optional);
■Thereare three Integrators, which can display the forward accumulation amount ,the reverse accumulation amount and the difference calculation amount respectively..There is an internal power-down clock, which can record 16 power-down times. (optional);

■ With infrared handheld operator, 115KHZcommunication rate, it can operate all functions of converter remotely without contact (optional).

Hot Products

NYRD900 80G High-Precision Measuring Radar Level Meter Support Remote Debugging 80G High-Precision ...
NYRD900 PTFE Antenna 80G Radar Level Meter Measuring Range 0.08 - 150m 80G Radar Level Meter Working ...
26G Horn Type Radar Level Meter NYRD806 High Frequency Small Blind Zone 26G Radar Level Meter The ...
26G Radar Level Meter NYRD809 Small Blind Zone High Frequency 26G Radar Level Meter Working ...
26G Radar Level Meter Aluminum Casting Shell NYRD810 Small Blind Range 26G Radar Aluminum Casting ...
The only radar that touches the medium Level meter transmitter NYRD701 Cable type 1.8GHz Radar Level ...