Power Backup Inverter Bi-directional Inverter 600W 12V25A
230VAC/50HZ
Energier Essential bi-directional inverter can be used in multiple
applications.You can use it
to compose power backup system. Or, with a quick setting,you can
compose a simple solar
hybrid system either with grid or diesel-generators.
Features,
-Bi directional inverter with pure sine wave output
-Can be applied for power backup and solar hybrid system
-High performance designed for all kinds of home appliances
-TBB premium II multi stage charging algorithm with built in
-automatic temperature compensation
-Equalization charging program was available
-Compatible with majority of cheap generators in the market
-Designed to work with weak grid
-Designed for tropical region with working temperature up to 60℃
-Optional CM was available for automatic generator start
-Dry contacts
-Optional SNMP card for remote internet access
Picture
Specification
Model No. | 12Vdc | CS0625L | CS1040L | CS2080L | | |
| 24Vdc | CS0615M | CS1020M | CS2040M | CS3060M | CS4080M |
| 48Vdc | | | | CS3030S | CS4040S |
INVERTER |
Nominal Voltage | 12Vdc, 24Vdc, 48Vdc |
power 30mins @25℃ (W) | 600 | 1000 | 2000 | 3000 | 4000 |
Cont.power@25℃ (W) | 600 | 1000 | 1800 | 2500 | 3600 |
Cont.power@40℃ (W) | 600 | 1000 | 1500 | 2000 | 3000 |
Cos φ | 0.9-1 |
Surge | 300% |
Output voltage【1】 | 230VAC or 110VAC ± 2% | 230VAC ± 2% |
Output frequency | 50Hz or 60Hz ± 0.1% |
Efficiency (MAX.) | 12Vdc | 88% |
| 24Vdc | 88% |
| 48Vdc | 92% |
Bypass range | UPS mode | 184VAC-264VAC/92VAC-132VAC | 184VAC-264VAC |
| GEN mode | 160VAC-280VAC/80VAC-140VAC | 160VAC-280VAC |
Crest factor | 3:1 |
THD | <3% |
Zero load power | 17 | 22 | 27 | 36 | 62 |
Zero load power (power save mode) | 4 | 5 | 7 | 9 | 15 |
Output circuit breaker | 5A | 10A | 15A | 30A | 30A |
Overheat protection | auto disconnect |
Overload protection | auto disconnect |
shortcut protection | auto disconnect |
Charger |
Nominal Output Voltage | 12Vdc, 24Vdc, 48Vdc |
Max Output current (A) - adjustable | 25/15 | 40/20 | 80/40 | 60/30 | 80/40 |
AC Input range | UPS mode | 184VAC - 264VAC/92VAC-132VAC | 184VAC - 264VAC |
| GEN mode | 160VAC - 280VAC/80VAC-140VAC | 160VAC - 280VAC |
Battery types | AGM / GEL / LFP / Flooded |
Absorption time | variable |
Temperature compensation | -4mV/℃/cell |
Charger circuit breaker | 5A | 10A | 15A | 30A | 30A |
Other Data |
Transfer time | UPS mode | 15ms |
| GEN mode | 2s |
Transfer switch | 40A |
Battery connector | M8 x 2 |
AC connector | Terminal block (M3 screw) |
Mechanical Data |
Enclosure | Steel with powder paint |
Dimension (mm) | 444x186x135 | 512x216x176 |
Net Weight (kgs) | 9.5 | 14 | 16 | 18.5 | 22.5 |
Cooling | Forced fan |
Protection | IP20 |
Standard |
Safety | EN60950-1 |
EMC | EN55022,EN55024 |
【1】Output voltage: 220VAC/60Hz for Philippines |