Home Companies YUEQING WINSTON ELECTRIC CO.,LTD.

WCM1 Molded Case Circuit Breaker 60HZ , Motor Circuit Breaker IEC60947-2

YUEQING  WINSTON  ELECTRIC  CO.,LTD.
Active Member

Contact Us

[China] country

Address: Floor 3rd,Liufeng Building,Liushi Town,Yueqing City,Zhejiang.325604.China

Contact name:Tess Wong

Inquir Now

YUEQING WINSTON ELECTRIC CO.,LTD.

WCM1 Molded Case Circuit Breaker 60HZ , Motor Circuit Breaker IEC60947-2

Country/Region china
City & Province zhejiang
Categories Battery Chargers
InquireNow

Product Details

WCM1 Molded Case Circuit Breaker 60HZ , Motor Circuit Breaker IEC60947-2

 

WCM1 series moulded case circuit breaker is one of products developed and manufactured by adopting international advanced technology. It is supplied with rated insulating voltage 550 and 800V and used for circuit of AC 50/60Hz, rated operating voltage AC 400V (or below), rated operating current up to 1600A for infrequent changing over and starting of the motors.The products conforms to IEC60947-2 standard.

TECHNICAL PARAMETER

Main Technical Specification(table1)

Type

Rated
current (A)

Polenum-ber

Ratedinsui-atingvolt-age(V)

Rated
operat-ingvolt-age(V)

Arcing-
over
distance
(mm)

Ultimate
short
circuit
breaking
capacity
(KA)

Servies
short
circuit
breaking
capacity
(KA)

Operation
perform-
ance

Utiliza-tioncat-egory

Load

Unload

WCM1-63L

(6),10
16,20
25 ,32
40,50
63

3, 4

500V

400V

0

25

18

1500

8500

A

WCM1-63M

0

50

35

WCM1-100L

(10),16
20,25
32,40
50,63
80,100

800V

0(≤50)

35

22

WCM1-100M

0(≤50)

50

35

WCM1-100H

0(≤50)

85

50

1000

7000

WCM1-225L

100,125
160,180
200,225

≤50

35

22

WCM1-225M

≤50

50

35

WCM1-225H

≤50

85

50

1000

4000

WCM1-400L

225,250
315,350
400

≤50

50

35

WCM1-400M

≤100

65

42

WCM1-630L

400,500
630

≤100

50

35

WCM1-630M

≤100

65

42

WCM1-630H

≤100

100

65

WCM1-800M

630,700
800

3

≤100

75

50

WCM1-800H

≤100

100

65

WCM1-1250M

1000,1250

≤100

100

65

WCM1-1250H

≤100

125

75

WCM1-1600M

1600

≤100

150

80


Note: 6A without thermal protection
The N-pole of four-poles breaker is sited at the right side of the product has four types:
Type A: Without current trip-lease on N pole which making all the time, not closing and opening with the other three poles.
Type B: Without current trip-release on N pole which closing and opening with the other poles.
Type C: With current trip-release which closing and opening with the other three poles.
Type D: With current trip-release which making all the time not closing and opening with the other three poles.

Protection Characteristic
The thermodynamic release of a circuit breaker provides the feature of inverse time-delay, while the magnetic release is the instantaneous operation as shown on table 2(distribution circuit breaker) and table 3 (motor protection circuit breaker).


Table2

Rated current of release (A)

Thermodynamic release( ambient temperature ) land +40°C marine +45°C

Operating current of magnetic release (A)

1.05In(cold state) Inoperative time(h)

1.30In(heat state) Operative time(h)

10≤In≤63

≥ 1

< 1

10In±20%

63

≥ 2

< 2

100≤In≤800

≥ 2

< 2

5In±20% 10In±20%



Table3

Rated current

Thermodynamic release ( ambient temperature ) land +40°C marine +45°C

Operating current of magnetic release (A)

of release (A)

1.0In(cold state) non-trip time(h)

1.20In(heat state) trip time (h)

1.50In(heat state) trip time (h)

7.2In(cold state) trip time(h)

10 ≤ In ≤ 225

≥ 2

<2

≤ 4min

4s < Tp ≤ 10s

12In±20%

225 ≤ In ≤ 630

≤ 8min

6s < Tp ≤ 20s



Accessories of Circuit breaker
1 The external accessories of the breaker
Motor-driven operation device
1) Wiring diagram of type CDM electromagnetic operation device(fitting AM1-63,100,225) seethe following drawing (wiring diagram of the external accessories of the breaker in the dotted frame)



Code description: SB1SB2stand for push button.(provided by users themselves) Number "1" "2" "3" stand for number of wiring terminals.
Voltage rating: AC50Hz 230V 400V DC 220V
2) Wiring diagram of type CD motor-driven operation device (fitting AM1-400 630 800) seebelows (wiring diagram of the external accessories of the breaker in the dotted frame)




Code description: SB1SB2stand for push button. (provided by users themselves) "X" stands for line connection terminals
Voltage rating: AC50Hz 230V 400V DC 220V



Rotary handle operation device
The mechanism is used in moulded case circuit breaker to operate the draw-out panel. Powerdistribution panel and supply box outside the panel by turning the handle ,and to ensure thedoor of panel would not be openned when the breaker being on. The hand-drive mechanism can be equiped with two types of operation, one is "A" modelsquare handle , the other is "B" model round handle.



4.2 Release pattern and accessories code

SHT: Shunt release; UVR: Under-voltage release;AX: Auxiliary contact; AL: Alarm contact

Release patternand accessories codeName/TypeWCM1-63,
100, 225
WCM1-400WCM1-630WCM1-800
200, 300No accessories200: magnetic release (only short circuit protection)300: thermal magnetic release(both overload and short circuit protection)
208, 308Alarm contact
210, 310Shunt release
220, 320Auxiliary contact
230, 330Under-voltage release
240, 340Shunt release
Auxiliary contact
250, 350Shunt release
Under-voltage release
260, 360Two group of auxiliary contact
270,370Under-voltage release
Auxiliary contact
218, 318Shunt release
Alarm contact
228, 328Alarm contact Auxiliary contact
238, 338Under-voltage releaseAlarm contact
248, 348Shunt release, Alarm contact,Auxiliary contact
268, 368Two group of auxiliary contact,Alarm contact
278, 378Shunt release, Alarm contact, Under-voltage release


According to user's demands, accessories could lead to direct wire outcoming or line wiringterminals could be added(please mark out in case of making order).

Under-voltage release
Wring diagram of the under-voltage module connected externally (the internal accessories inthe dotted frame)Ue: AC50Hz 230V, 400V



When the operation voltage is 35%~70% of the rated voltage, the under-voltage release shouldmake the breaker trip correctly.When the operation voltage is 85%~110% of the rated voltage, the under-voltage release shouldmake the breaker close.In case of the operation voltage less than 35% of the rated voltage, the under-voltage shouldprevent the breaker from closing.Note: Only the under-voltage release should be energized in advanced, the breaker could berecramped and turned-on, otherwise the breaker will be damaged.


Shunt release
Scheme of wiring(the internal accessories in the dotted frame)"K" is the slow motion switch normal-close contact connect the coil in series in the shunt release.It turns-on or turns-off voluntarily as soon as the breaker on or off.



Voltage rating: AC50Hz 230V or 400V, DC 110V 220VThe shunt release should make the breaker trip reliably when the operation voltage is 70%~110%of the rated control voltage.

 Alarm contact 
 The position of the breaker in "off" or "on" 
 The position of the breaker in "free trip" (alarm) 
 B11 and B12 switch from "close" to "open", statusof B11 and B14 switch from "open" to "close"


 

Auxiliary Contact
When the breaker is in"off"For the breaker with frame current400A and above
For the breaker with frame current225A and below
When the breaker is in"on"When the breaker is in "off", the contacts switch from "close" to "open".When the breaker is in "off",the contacts switch from "open"to close"

 

Hot Products

China SA Series ( CJX9 ) Air conditional 30A 380V AC Contactor Application This series contactor is ...
3TB Series 660 Voltage Ac Contactor Electrical 3TB40 3TB43 3TB44 Application The contactor is ...
Customized Widely Used 3TD Mechanical Interlocking AC Contactor Application The contactor is ...
Fast Transportation WCT 16A 1 Phase NO Household AC Contactor Product description WCT contactors can ...
Chinese Electric Magnetic 24v WCT NC 16A 2 Pole Mini Contactor Product description WCT contactors ...
General Electric WCT 1 NC NO 16A 2 Pole 220V Small AC Contactor Product description WCT contactors ...