In Row Air Conditioning Cooling Unit For High Heat Density Data Center

Country/Region china
City & Province hefei anhui
Categories Toilet Tissue
InquireNow

Product Details

In Row Air Conditioning Row Based Cooling Unit For High Heat Density Data Center

 

Product Introduction                                

 

Cool Row series In Row air conditioning increase the heat density of the data center and realize the energy saving of the data center. Compared with traditional computer room air conditioners, In Row air conditioning have the characteristics of 100% sensible heat ratio, low fan power consumption, high energy efficiency ratio, low computer room decoration requirements, convenient installation, standardized cabinet design and easy expansion.
 

Features & Advantages                           

  • It achieves a 100% high sensible heat ratio, which effectively reduces the overall humidification and dehumidification energy consumption of the computer room.
  • Control the air volume and cooling output as required, and cooperate with EC fan, electronic expansion valve and DC inverter compressor to achieve the best effect and lowest energy consumption;
  • Adjust the speed of the internal fan according to the refrigeration demand, which can effectively reduce the noise;
  • Group control function, realize up to 32 sets of group operation, including automatic main-standby switching, automatic operation of backup units, round robin, competition avoidance operation, temperature and humidity sensor sharing, etc.;

 Applicable Scene                                   

 

■Local overheating area

 

■ High heat density data center

 

■ Modularized data center

 

■ Container data center

 

■ Data centers with insufficient floor heights that cannot use down-supply air or pipelines

 

■The cabinet adopts cold and hot aisle layout

High Efficiency-DC Inverter Compressor of DX System

Dynamic cooling to adapt to the rapidly changing load of the computer room; Save energy and improve energy efficiency under low load; It can greatly reduce the number of compressor starts and stops, and improve system reliability

 

High Efficiency-Backward Centrifugal EC Fan

Compared with ordinary standard AC motors, the electronically commutated synchronous EC motors can save energy by 30%;

Automatically adjust the fan speed according to the cooling demand or wind pressure, and provide the air volume on demand;

Fan N+1 redundant configuration, any fan failure can still ensure full air volume operation;

Soft start function, low starting current; Easy maintenance design

 

High Efficiency-Electronic Expansion Valve

Smoothly adjust the throttle opening, matched with variable capacity compressor To achieve energy saving;

Wide adjustment range, reduce superheat and improve energy efficiency ratio Reduce cooling capacity and load;

Fast response speed, realizing precise refrigeration;

Structure & Components                 

 

 

Technical Parameter                                                                

 

ModelCRA013ACRA020ACRA040ACRA050ACRA060A
Air supplyFront/SideFront/SideFrontFrontFront
Power supply380VAC/3Ph/50Hz
Cooling capacity-KW13.226.742.653.363.9
Sensible cooling-KW13.226.742.653.363.9
Compressor
RefrigerantR410A
Quantity1
Fan
Fan typeEC Centrifugal fan
Quantity45233
Air volume-m3/h3200500088001100012500
Heater
Heat typePTC    
Capacity-KW23666
Humidification
Capacity-KW11.5333

 

Certificates                                               

 

Factory Details                                           

 

Packing & Delivery                                                        

 

 

Cases                                                                                     

 

 

Hot Products

Precision Air Conditioners 80-90KW Cooling Capacity For Precise Equipment Workshop Products ...
Large Cooling Capacity Precision AC System For Network Management Center Products Introduction Large ...
Precision Cooling Units Air Cooling Systems For Switch Rooms And Mobile Computer Rooms Products ...
30-45KW PAC Units For Precise Equipment Rooms And Data Storage Center Rooms Product Introduction ...
Precise AC Units 100-120kW Providing Constant Temperature And Humidity In Data Centers Products ...
PAC System With 50-80KW Applied In Server Rooms, Communication Equipment Rooms Products Introduction ...