Space Saving Computer Room Air Conditioning Unit 15KW Floor Standing Type

Country/Region china
City & Province hefei anhui
Categories Toilet Tissue
InquireNow

Product Details

 

 

Computer Room Air Conditioning Floor Standing Type To Save Space 15KW

Product Introduction                                                               

Coolnet precise air conditioning is dedicated to the equipment room and machinery room that place communication apparatus, computers, precise instruments, etc. Coolnet precise air conditioning can achieve efficiency controlling of the ambient temperature and humidity with more precision than normal type of air ocnidtioners, in this way, the long-term stable and continuously run of the unit can be guaranteed.

 

 

 

 

Features & Benefits                                                             


 

 
Scope Of Applications                                                                                    

 

IDC, Computer room Network equipment room, Server room, communication equipment room Monitoring room, Power distribution room and battery room High precision lab, Test room, Inspection room, Measuring room Industrial control room, High precision workshop Archive, Storage room, Museum, Wine cellar​

 

Structure & Components                                                                      

 

Fan                                                   
A blow fan adopts direct drive centrifugal fan with backward curved blades, the range of static pressure can be adjusted from 0 to 400pa, realizing the continuous operation of 365 days* 24 hours, 10 years’ average life.
 
 
 
 
 
Compressor                                   
The core power of the unit is from Copeland hermetic scroll compressor that guarantees the high efficiency ,low noise and the long life of the unit.

 

Air Supply Method                                          
 

 

 

 

ModelM04M06M08M13M16M20
Power Supply220V1Ph-50Hz380V3Ph-50Hz
Air dischargeUp Front/Down
Technical Data Sheet
AC FanTotal cooling capacity-KW4.26.47.512.516.820.2
Sensible cooling capacity-KW3.95.86.911.315.318.3
Unit FLA-A(heating, humidifying type)20.025.016.822.023.528.6
Compressor Quantity1
Fan Quantity1
Air Volume-m3/h160019002300360051006500
Heater Capacity-KW3.03.06.06.06.06.0
Humidification-kg/h333366
Power of humidifier-KW2.32.32.32.34.54.5
Outdoor Condenser
ModelSCA020SCA020SCA030SCA030SCA050SCA050
Standard unit operating temperature range-℃-15-45℃
Low Temperature Components Operating Temperature Range-℃-40-45℃

 

 

Certificates                                               

 

Factory Details                                                  

 

Packing & Delivery                                                     

 

 

 

 

Cases                                                        

 


 
 
 

Hot Products

Rack Mount Split Precision Air Conditioner 12000btu For Bank/Data Center Product Introduction ...
Precision Air Conditioning Cooling System For Large Computer Rooms IDC Internet Data Center Product ...
Precision Laboratory Precision Air Conditioner And Constant Temperature And Humidity Air Conditioner ...
Precision Air Conditioner Designer Solution In Computer Room Product Introduction The computer room ...
Precision AC Air Conditioning For Telecom And Data Center Products Introduction Coolnet precision ...
Server Air Conditioner Cooling Machine For Telecommunications Network Product Introduction Sever air ...