PDU Safe Power Distribution Unit Horizontally / Vertically Installed

Country/Region china
City & Province hefei anhui
Categories Other Chargers
InquireNow

Product Details

PDU provides safe power distribution and can be installed horizontally or vertically

 

Production                                                  

Intelligent monitoring PDUs are complete and versatile, and can meet the needs of high-end server rooms and data centre software intelligent power distribution and environmental monitoring systems. Intelligent PDUs can monitor both current, voltage, electrical energy, power factor, carbon emissions, fuse status, surge effectiveness and other data. It can also monitor temperature, humidity, flooding, access control, human body sensing, etc. through sensors. Remote control via CP/IP, SNMP and other protocols Power on/off, sequential power on/off, threshold alarm management, authority management, a good helper for power management. Intelligent solutions allow users to Enable power distribution to be embedded into the server room dynamic loop management system. More precise and effective monitoring of energy consumption, equipment operation control and monitoring of the server room environment.

 

 Functions of Intelligent PDU                                           

 

1, Energy Monitoring Function

It can provide abundant functions such as energy usage, efficiency and environmental monitoring in data center etc. The input voltage and current of each circuit can be measured by intelligent PDU, and the usage of power can be calculated in watts or kilowatts. The total energy usage can be calculated, from which the operators of data center decide whether they need to add PDU or not.

2, Environmental Monitoring Function

Environmental monitoring and management can be carried out through the existing data center LAN by new generation of intelligent PDU. Intelligent PDU integrates multiple temperature and humidity/moisture sensors. Intelligent PDU can track environmental factors and issue warning timely. In addition, the administrator can also compare the environment data with the energy consumption data to confirm the energy consumption of the server, and inspect actual effect of the temperature control measures for inner rack.

3, PDU Access and Network Function

Intelligent PDU can be connected through the LAN form, and be flexibly managed through a Web browser or command line interface (CLI).lt makes the administrator easily access the data, for real-time monitoring.

 

Software Function                                           

  • Simultaneously detect the power consumption of multiple intelligent power distributors
  • Group function, administrators can define and classify by themselves, which is convenient for management
  • Provide power consumption icon, which can be viewed by day, month, or self-defined way
  • When a power accident occurs, emails can be sent to the account designated by Trap


Parameter                                                 

 

PDU

 

Parameters

 

 

input

Input typeAC single phase, AC three phase,-48VDC,240VDC,336VDC
Input mode

Transparent open type junction box,power cord, cable,

industrial connector, socket etc.

Input voltage range100-277VAC/312VAC-418VAC/11VDC-240VDC/-43VDC- -56VDC
AC input frequency50/60Hz
total load currentMAX 63A

 

 

Output

Storage temperature-40 - +70
Relative humidity5-95% (No condensation)
Atmospheric pressure70kPa - 106kPa
Working altitudeNo more than 4000M

 

 

Environmental

Working temperature-10 - +75
Storage temperature-40 - +80
Relative humidity5-95% (No condensation)
Working altitudeNo more than 4000M
IP ratingIP20
Protectioninput protection moduleCircuit breaker, lightning protection, leakage protector, temperature insepction module (optional)
Output protection moduleCircuit breaker, fuse box, fuse(optional)

 

Certifications                                            
Keeping Stable And Safe Current Bitcoin PDU With CSA And UL Certifications 3

Case                                                         
Keeping Stable And Safe Current Bitcoin PDU With CSA And UL Certifications 4

 

Factory                                            
Keeping Stable And Safe Current Bitcoin PDU With CSA And UL Certifications 5

 

 

 

 

Hot Products

Quiet And Efficient Indoor Precision Air Conditioning Unit 17.5kW 20.2kW For Base Stationc Products ...
Quiet And Efficient Indoor Precision Air Conditioning Unit 17.5kW 20.2kW For Base Stationc Products ...
Constant temperature and humidity Computer Server Room Precision Air Conditioner Product Introductio...
CNM Series High-Frequency Online Modular UPS Product Description CNM series rack-mount modular UPS ...
Efficient Power Solutions with CNM Series Rack-Mounted Modular UPS Product Description Welcome to ...
Next-Gen Power Management: Three Phase In Three Phase Out Modular UPS Product Description Welcome to ...