AC Single Phase three phase Cabinet Power Distribution Socket 220VAC

Country/Region china
City & Province hefei anhui
Categories Other Chargers
InquireNow

Product Details

Cabinet power distribution socket

 

Product Introduction                                     
 

Intelligent monitoring PDUs are complete and versatile, and can meet the needs of high-end server rooms and data centre software intelligent power distribution and environmental monitoring systems. Intelligent PDUs can monitor both current, voltage, electrical energy, power factor, carbon emissions, fuse status, surge effectiveness and other data. It can also monitor temperature, humidity, flooding, access control, human body sensing, etc. through sensors. Remote control via CP/IP, SNMP and other protocols Power on/off, sequential power on/off, threshold alarm management, authority management, a good helper for power management. Intelligent solutions allow users to Enable power distribution to be embedded into the server room dynamic loop management system. More precise and effective monitoring of energy consumption, equipment operation control and monitoring of the server room environment.


Advantages                                                            

  • Flexible Policy Management
    According to the usage of each power equipment, users can customize the configuration strategy. Based on the user's policy management and monitoring events, the product supports centralized management and automatic cycle control, manages several devices at the same time in one interface, and independently sets the power switch cycle, which is convenient and practical.

     

  • Energy metering, energy consumption evaluation
    The PDU can manage the power consumption of electric equipment, calculate the power factor, and evaluate the energy consumption of electric equipment. If the power factor is low, the power loss is large during the transmission process, and the power consumption suddenly increases, the PDU can adjust the power consumption status of the equipment through settings, and send an alarm to the user by SMS or email.

     

  • Support remote control, easy to manage
    The PDU can be connected to the local area network or the Internet. Users can remotely control the PDU through a computer, and query, connect, disconnect or restart the power supply of each device connected to the port, which completely breaks the constraints of distance and region.

 

Functions                                  

Energy Monitoring Function

It can provide abundant functions such as energy usage, efficiency and environmental monitoring in data center etc. The input voltage and current of each circuit can be measured by intelligent PDU, and the usage of power can be calculated in watts or kilowatts. The total energy usage can be calculated, from which the operators of data center decide whether they need to add PDU or not.
 

Environmental Monitoring Function

Environmental monitoring and management can be carried out through the existing data center LAN by new generation of intelligent PDU. Intelligent PDU integrates multiple temperature and humidity/moisture sensors. Intelligent PDU can track environmental factors and issue warning timely.
 

PDU Access and Network Function

Intelligent PDU can be connected through the LAN form, and be flexibly managed through a Web browser or command line interface (CLI).lt makes the administrator easily access the data, for real-time monitoring.
 

 

Installation method                                     


 

Parameter                                                 

 

PDU

 

Parameters

 

 

input

Input typeAC single phase, AC three phase,-48VDC,240VDC,336VDC
Input mode

Transparent open type junction box,power cord, cable,

industrial connector, socket etc.

Input voltage range100-277VAC/312VAC-418VAC/11VDC-240VDC/-43VDC- -56VDC
AC input frequency50/60Hz
total load currentMAX 63A

 

 

Output

Storage temperature-40 - +70
Relative humidity5-95% (No condensation)
Atmospheric pressure70kPa - 106kPa
Working altitudeNo more than 4000M

 

 

Environmental

Working temperature-10 - +75
Storage temperature-40 - +80
Relative humidity5-95% (No condensation)
Working altitudeNo more than 4000M
IP ratingIP20
Protectioninput protection moduleCircuit breaker, lightning protection, leakage protector, temperature insepction module (optional)
Output protection moduleCircuit breaker, fuse box, fuse(optional)

 

Certification                                                  

 

Case                                                

 

Factory                               

 

Hot Products

Dual Cooling System Precision Air Conditioning For Small and Medium Computer Room Product Introducti...
Cool Smart Series 6 - 20KW Precision Air Conditioner Cool Smart Series 6-20KW PACU Specially ...
Quiet And Efficient Indoor Precision Air Conditioning Unit 17.5kW 20.2kW For Base Stationc Products ...
Quiet And Efficient Indoor Precision Air Conditioning Unit 17.5kW 20.2kW For Base Stationc Products ...
Micro Module Data Center For Data Storage Product Introduction The micro data center infrastructure ...
3.5-10.5KW Cooling Capacity Micro Data Center Rack Mountable Product Introduction Ranging in size ...