Vlf 80kv AC Hipot Test Equipment Very Low Frequency AC Hipot Test Set

 

General information

 

VLF stands for Very Low Frequency. VLF is generally considered to be 0.1 Hz and lower, its major application is for testing solid dielectric cable, transformers, motors, generators, switchgear and other electrical apparatus.
 

Features:

 

1. Adapts microprocessor controlled, can realize voltage set-up/down, measuring and protecting automatically. Manual intervention is allowable even during the auto voltage boosting.


2. The data of current, voltage, and waveform can be sampled at HV side.


3. Closed-loop negative feedback circuit is adopted. No capacity rising during outputting.

 

4. Portable, easy to move.


5. A high voltage output protective resistor is provided in the voltage boost body in the design and this eliminates the need of additional protective resistor connected outside.


6. Large LCD can display waveform clearly, and test report can be printed. Built-in printer.

 

7. Over voltage and current protection: When the output is beyond the limitation, the control unit will shut itself down within 20ms.

 

Specifications


1. Peak voltage: 80kV


2.  Fuse: 20A 

 

3.  Output frequency: 0.1Hz, 0.05Hz and 0.02 Hz (selectable)

 

4. Maximum load capacity: 0.5μF@0.1Hz; 1.0μF@0.05Hz; 2.5μF@0.02Hz


5. Power supply: 220V ±10%, 50Hz ±5% (If using a portable generator, make sure the output voltage and frequency are stable. Power >3kW. Power supply @ 110V 60Hz is optional)


6. Output voltage accuracy: peak voltage instability ≤1%; frequency instability ≤3%.
7. Voltage waveform distortion: ≤5%.


8. Working environment: indoor or outdoor; -10ºC-+50ºC; 85%RH.


9.  Weight: Control unit - 4kg; HV unit I: 25kg; HV unit II: 45kg.

Remarks: Capacitance of test object cannot be larger than the maximum value of the test instrument. If capacitance of test object is smaller than 0.05μF, the hipot should be equipped with an auxiliary device (supplied by Sansion Power Electric at your option).


Please contact us for further information. Sansion Power has a technically experienced expertise team to select correctly designed test set for you.

 

Hot Products

Test Object and Requirement The system is specially designed for AC withstand voltage test for below ...
AC Resonant Test System For Busbar GIS Cable Insulator AC resonant test system is used for factory ...
Transformer Power Testing System Capacitance / Tan Delta Tester General information: SXJS-III is a ...
10kv 12kv Transformer Capacitance Dissipation Factor Tester Power Testing System Dielectric Loss ...
Three Phase Power Testing System Capacitance Inductance Tester Automatic General information: SXDR-G ...
Insulation Gloves Boots Dielectric Test Set General information: Electrical workers wear rubber ...