Low Voltage ABC Cable A16mm Luminum Conductor XLPE Insualted ABC Overhead Cable

Country/Region china
City & Province shanghai shanghai
Categories Power Cables
InquireNow

Product Details

Product Description

Low Voltage ASTM Standard Overhead Aluminum Conductor XLPE Insualted ABC Cable

Introduction

ABC Cable used for low voltage ( 1500V ) overhead transmission line , Phase line is aluminum conductor , PE or XLPE insulated , the number of phase line will be two or three or four , Neutral line is aluminum conductor , it can be bare conductor or with PE or XLPE insulated

Specifications

Standard: National Standard IEC and ASTM

Rated Voltage: 0.6/1KV, 11KV, 33KV
 

Construction
Phase conductor: aluminum stranded(AAC)

Neutral conductor: aluminum stranded(AAC), aluminum alloy stranded(AAAC), aluminum conductor steel reinforced(ACSR)

Insulation: XLPE or PE

Application:  The cables are designed for aerial power lines and room-entrance wires with voltage up to and including 0.6/1KV.

Uesd for overhead service application such as street linghting, outdoor lighting and temporary service for cunstruction.which improves the safety and reliance of electrified wire netting.


1 Type

Duplex Service Drop, Triplex Service Drop, Quadruplex Service Drop

    a Duplex Service Drop

   Applications:To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting . For service at 600 volts or lower at a conductor temperature of 75 maximum.

   b Triplex Service Drop

   Applications: To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation .

    c Quadruplex Service Drop

    Applications: Used to supply 3 phase power , usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made . To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.

 

2  Construction

     a Phase Conductor construction:The phase conductor is aluminum alloy 1350-H19 hard-drawn, compressed concentric-lay-stranded.

     b  Neutral Conductor Construction
Cable assemblies are available with the following neutral conductors:

Aluminum conductors, coated-steel reinforced (ACSR), concentric-lay-stranded

Aluminum alloy 1350-H19 hard-drawn, concentric-lay-stranded

Aluminum alloy 6201-T81, concentric-lay-stranded

    c Insulation Material
The standard insulation on the phase conductor is black low-density crosslinked polyethylene (XLPE)

Alternatively, black linear low-density polyethylene (LDPE) insulation with a 75°C temperature rating is available upon request.

 

Phase conductor
Nominal cross section areaMm210162535507095120
Number of cores 33333333
Roots/diameter of phase conductor 7/1.357/1.77/2.147/2.547/3.019/2.1619/2.5419/2.86
Approx diameter of compacted conductormm4.054.8678.31011.613.2
Nominal thickness of insulationmm1.01.21.21.41.41.41.61.6
Diameter of phase coremm6.057.28.49.811.112.814.816.4
Max D.C resistance at 20ºCΩ/KM3.081.911.20.8680.6410.4430.320.253
Approx weight of phase coreKg/km127.24196.29277.24380.8510.47686.22954.141176.96
Messenger conductor
Nominal cross section areaMm210162535507095120
Number of cores 11111111
Roots/diameter of phase conductor 7/1.357/1.77/2.147/2.547/3.019/2.1619/2.5219/2.82
Approx diameter of messenger coremm4.055.16.427.62910.812.614.1
Max D.C resistance at 20ºCΩ/KM3.081.911.20.8680.6410.4430.320.253
Approx weight of messenger coreKg/km27.6243.869.494.71136.38192.98262.66328.94
Breaking loadKN1.652.073.34.56.28.912.315.6
Complete cable
Approx diametermm13.4316.1519.1322.3225.5929.434.4938.84
Approx weightKg/km154.86240.09346.64475.51646.85879.21216.81505.9
Packing lengthM/Drum10001000100010001000500500500

 

Hot Products

Product Description YJV32 YJV72 600/1000V XLPE copper Cable Armoured Power Cable Cable Selection It ...
Product Description 600/1000V 4x150mm2 XLPE Copper Cable YJV32 Armoured Power Cable Cable Selection ...
Product Description 600/1000V 3x150mm2 XLPE Copper Cable YJV32 Armoured Power Cable Cable Selection ...
Product Description 600/1000V 4x120mm2 XLPE Copper Cable YJV32 Armoured Power Cable Cable Selection ...
Product Description 600/1000V 4x95mm2 XLPE Copper Cable YJV32 Armoured Power Cable Cable Selection ...
Product Description 600/1000V 4x70mm2 XLPE Copper Cable YJV32 Armoured Power Cable Cable Selection ...