Home Companies Hangzhou innovation technology co.ltd

ATS-20AF-k Electrostatic Elimination Air Blower for plastic film move static 220v*1.4A

Hangzhou innovation technology co.ltd
Active Member

Contact Us

[China] country

Contact name:Kenna

Inquir Now

Hangzhou innovation technology co.ltd

ATS-20AF-k Electrostatic Elimination Air Blower for plastic film move static 220v*1.4A

Country/Region china
Categories Solar Chargers
InquireNow

Product Details

220v ATS-20AF-k Industrial Ionizing air blower for solving the static problem of bad industrial environment

 

ATS-20AF-k Industrial Ionizing air blower is designed for solving the static problem of bad industrial environment . It’s a kind of high efficient, wide range of. Air cover, it can effectively reduce the aggregate production process such as cutting,bending, plastic components conveying and packaging process stubborn charge.
 

Working principle:
ATS-20AF-k Industrial Ionizing air blower Can produce a lot of air with positive and negative Ion, the electric charges on the object and fall, when the object surface is negatively charged, It will attract positive charge in the air, when the object surface is positively charged, it will attract negative charges in the air, so that the electrostatic on the surface of the object and, to eliminate the purpose of static electricity.


Maintenance:
Emission head cleaning, ion balance adjustment, in addition to static correction, to ensure the normal work of ion fan.
1. Cleaning: clean emission point transmitter transmitter, sliding or rotating cleaning brush, until clean net ion emission tip, at least once a week.
2. The air inlet, outlet air cleaner: entrance and ionized air outlet should be clean to prevent the obstruction of airflow, can use soft brush to clean or compressed air cleaner.

3. Ion balance test: eliminate the time by measuring the electrostatic electrostatic analyzer
4. Electrostatic elimination time test: eliminate the time by measuring the static electrostatic analyzer
5. Ion fan, output design for ion amount is balanced, fixed. As may be affected by the voltage fluctuation, ambient air humidity and other factors will form the residual voltage offset ion balance. Offset standards: 0V ± 10V. If the static elimination time and residual voltage has a large deviation, should be sent to the factory for alignment.


Governor Use Instructions

  1. Single phase voltage regulator: A, X terminal for input, a, x terminal for the output .
  2. If the regulator is newly installed or not used for a long time, the regulator need to use 500V Meg-ohmmeter to measure the insulation resistance of coil to ground before running. And it is safe to use only when the resistance not be lower than 5 meg-ohm, otherwise it should be subjected to heat and drying treatment. After drying, should check whether the fastener loosed. If loose, it should be tightened.
  3. Before use, the power supply voltage and the negative charge current must be identified. It should in accordance with the provisions of the regulator.
  4. When in use, the pointer on the knob should be adjusted to the 0, then the load terminal need to be connected to the output. Last connect to the good grounding wire to ensure safety.
  5. Connect the appropriate power supply to the input terminal, and then slowly adjust the knob, to make the output voltage achieve the required value.
  6. In order to avoid damage brush or contact parts flame out and winding burn, need to adjust the speed of a circle by the button, one circle should not be less than 5 seconds.
  7. After finish the work, if not uses soon later, be sure the pointer and the knob is in 0, and cut off the power supply.
  8. The contact surface of winding and brush should be kept clean. If any black spot, can wipe with cotton yarn dipped in alcohol (90%), until the spot be cleaned away.
  9. The wire and wire terminal of power supply to the regulator, regulator to the load should be good connected. And can adjust the current through the regulator.
  10. When moving regulator, should use handle the whole regulator to lift and move, not to handle the knob.
  11. Do not allow water droplets or oil fall into the internal of regulator, and should clean the dust inside the power regularly.
  12. Should be well ventilated to prevent overheating.


The external connection is corresponding to as follows:

1. red wire(red) —— A (Input)
2. blue wire (blue) —— X or x (Zero), because X and x were connected inside each other
3. black wire (black)—— a (Output)
4. yellow wire (yellow) ——Ground Connection

Product features:
* Suitable for big range to eliminate static electricity;
* Electrostatic quickly moving, convenient installation;
* With ion emitter cleaner;
* Inside there is fan and high voltage generator;

Applications:
Blowing Machinery ;Precision electronic products; electronic assembly line, medical manufacturing assembly lines, printing, packaging; forming of fine products.


Specification

Operating Voltage220V
Current Consumption1.4A
Operating Temperature-10~50℃
Size550mm(L)×240mm(W)×370mm(H)
Weight17.5kg
Air Volume0--410CFM
Offset voltage0v±10v
Air Coverage60cm×30cm
Discharge Time (5000v-500v at 300mm)≤0.6s

 

Speed rotary switch

Hot Products

DC503S (Case type) high power 30KV Charging Generator high voltage power supply 100V~240VAC 1. ...
VCM60S-P Static Charging Generator Input Voltage100V~240VAC Output Voltage 0--60kv Adjustable ...
VCM60-P Charging Generator Stepless adjustable voltage from 0--60kv VCM60-P Static Charging ...
DCB02 Portable Static Charging Bar Customized Length From 10cm To 300cm 60kv Maximum input voltage ...
VCM50-N Static Charging Generator Input Voltage 100V~240VAC Output Voltage 0--50kv Adjustable ...
VCM60 Series Charging Generator Stepless adjustable voltage from 0--60kv; VCM60 series Charging ...