China Kayi Industrial Co., Ltd. |
Grey 36kV Drop Out Fuse Cutout For Distribution Overhead Power Lines
1, Our advantages:
a, Over 20 years of manufacturing experience with good quality & stable product performance.
b, We provide full line of MV-HV electrical products, including
drop-out fuse, disconnector, surge arrester, vacuum circuit
breaker, fuse, load switch, insulator etc.
c, Quick feedback, Timely quotation, Fast delivery
d, Complete set of testing machine to ensure product quality.
e, We can customize non-standard product as per client’s
requirement.
f, We sell pressing parts& pressing mould at low price.
g, We offer electrical installation & commission service.
h, We also provide OEM service.
2, The structure of our products
3, Packaging & Delivery
Packaging Details: | Standard exporting package(carton, wooden case and pallet) FUSE CUTOUT |
4,Technical Specifications of our products
10KV-12KV
Basic Data | ||||
Type | Rated voltage (KV) | Rated Current (A) | Breaking current (A) | Impulse voltage (BIL) |
HRC1-10 | 10-12 | 100 | 10000 | 110 |
HRC1-10 | 10-12 | 200 | 12000 | 110 |
Power frequency withstand voltage | Leakage distance (mm) | Weight (kg) | Dimensions (cm) | |
40 | 250 | 7.3 | 38.5*34.5*10.5 | |
15KV-17KV
Basic Data | ||||
Type | Rated voltage (KV) | Rated Current (A) | Breaking current (A) | Impulse voltage (BIL) |
HRC1-15 | 15-17 | 100 | 10000 | 125 |
HRC1-15 | 15-17 | 200 | 12000 | 125 |
Power frequency withstand voltage | Leakage distance (mm) | Weight (kg) | Dimensions (cm) | |
45 | 350 | 8.5 | 38.5*34.5*10.5 | |
22KV-27KV
Basic Data | ||||
Type | Rated voltage (KV) | Rated Current (A) | Breaking current (A) | Impulse voltage (BIL) |
HRC1-24 | 22-27 | 100 | 10000 | 125 |
HRC1-24 | 22-27 | 200 | 12000 | 125 |
Power frequency withstand voltage | Leakage distance (mm) | Weight (kg) | Dimensions (cm) | |
66 | 450 | 8.5 | 38.5*34.5*10.5 | |
33KV-36KV
Basic Data | ||||
Type | Rated voltage (KV) | Rated Current (A) | Breaking current (A) | Impulse voltage (BIL) |
HRC1-36 | 30-36 | 100 | 10000 | 125 |
HRC1-36 | 30-36 | 200 | 12000 | 125 |
Power frequency withstand voltage | Leakage distance (mm) | Weight (kg) | Dimensions (cm) | |
70 | 660-720 | 816 | 57*38*14.5 | |
4, Products
5, HRC1 cutout fuse 100a
General
HRC1 FUSE CUTOUT is suitable for power transformer and line short circuit, over-load protection as well as breaking and making load current using in power system which rated frequency 50Hz, rated voltage 35KVor less, installing high voltage side of power distribution main line.