Home Companies Ningbo Sanmin Import And Export Co.,Ltd.

Nbsanminse Qg - Z 1-1/2 2 2-1/2 3 Inch Replaced Goyen Solenoid Pulse Valve Dust Collector Double Diaphragm Valve

Ningbo Sanmin Import And Export Co.,Ltd.

Contact Us

[China] country

Trade Verify

Contact name:Ina Chen

Inquir Now

Ningbo Sanmin Import And Export Co.,Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Nbsanminse Qg - Z 1-1/2 2 2-1/2 3 Inch Replaced Goyen Solenoid Pulse Valve Dust Collector Double Diaphragm Valve

Country/Region china
City & Province ningbo zhejiang
Categories Valves
InquireNow

Product Details

Nbsanminse Qg - Z 1-1/2 2 2-1/2 3 Inch Replaced Goyen Solenoid Pulse Valve Dust Collector Double Diaphragm Valve

 

 


Performance and cost-effectiveness are essential for dust collector systems
Dust collector systems in a wide range of industries, including the following:
Concrete Processing
Grain, Agriculture and Feed
Metal Working (Abrasive Blasting)
Food Processing
Foundries
Pharmaceutical
 
Size:
15 = G1/2"
20 = G3/4"
25 = G1"
35 = G1-1/4"
40 = G1-1/2"
50 = G2"
62 = G2-1/2"
75 = G3"
76 = G3"
89 = G3"
102 = G4"
 

Pulse valve is composed of pilot head, diaphragm and valve aluminum body. The back cavity area of diaphragm is bigger than the front one. The diaphragm is kept at the closed position due to the effect of big pressure.


Electrical pulse controller send input signals so that the electromagnetic armature attracts the moving bar. Unclose the balancing hole to release the pressure gas in the back cavity of diaphragm quickly; the pressure gas in the front cavity holds up the diaphragm to open the passage and the valve starts cleaning.


The pulse signal disappears and the spring of the armature works immediately to resume the moving bar so as to close the balancing hole. The pressure gas in the back cavity of the diaphragm and the spring work together to close the passage the valve stops cleaning.


The damping hole in the diaphragm functions to damp the airflow when the moving bar of armature holds up for balancing and to transit the air to the back cavity as soon as the balancing hole is shut to close the passage and stop cleaning.

 

Technical Parameter

 

 Right angleEmbeddedInlinePlug
Design-pressure0.3~0.8MPa0.2~0.8MPa0.3~0.8MPa0.2~1.0MPa
Working-pressure0.3~0.6MPa0.2~0.6MPa0.3~0.6MPa0.2~0.6MPa
Ambient Temperature-25~60℃ Customized for lower or higher temperature
Relative Humidity≤85%
Working MediumClean Air
VoltageAC220V/DC24V/AC110V/AC24V Customized
Protection ClassIP65
Diaphragm LifeOver One Million Cycles
Cv/KvCall us for detail

 

Material Construction

 

BodyADC12 die cast
Armature430FR stainless steel
DiaphragmNitrile or viton
Spring321 Stainless steel
Fasteners302 Stainless steel

 

Common failure and troubleshooting

 

Use period
Failure phenomena
Possible Reason
Troubleshooting
During installation and commissioning
The valves cannot all be opened, but the leading part does act.
Check the gas dome pressure to see if it is too low.
Check the leakage
Some valves do not work, but the others are normal.
Check the valve coil connection and coil
Replace the accessories
The valves cannot all be closed. There is leakage. There is no way to establish a gas dome.
Y-valve. Some valves for the same gas dome are leaking, thus causing leakage for all the valves.
Check the leakage
Z-valve. The valve inlet and blowing muzzle are installed backwards.
Re-install
Some valves cannot be closed. There is leakage.
There is some dirt or debris on the membrane, ii is blocking the moving iron core.
Clean the membrane and check that the membrane is complete. Check the moving iron core and air lock.
A valve closing is slowly.
The membrane orifice is blocked.
Dredge the membrane orifice
During use period
Some valves are leaking. The membrane cannot close tightly and the valve is always open a
little.
There is some dirt or debris on the membrane, the leading part is damaged. Moving iron core is blocked.
Clean the membrane and check that the membrane piece is complete. Check the moving iron core and the air lock. Replace the accessories if necessary.
Coil is hot and burned out.
It has been turned on for too long.
Check the working condition of the control system.
Voltage exists but the valve does not operate.
Membrane is damaged and the orifice is blocked.
Replace the accessories in time.
Ambient temperature is below -20℃. The valve is leaking and cannot open.
Ambient temperature is too low and here is frost in the valve.
Pay attention to insulation and maintaining proper temperatures.

 


Hot Products

JMFH Pneumatic Solenoid Valve Pneumatic Air Valve Control Valve Festo Original FAQ Q: How much is ...
MSEB Solenoid Valve Pneumatic Air Valve Control Valve Festo Original FAQ Q: How much is our minimum ...
Pressure:0.2-1.0Mpa Temp:- 10°C~ 60°C Seal:NBR+PUR Waterproof:IP65 Design: slide valve sleeve type
Pressure:0.2-1.0Mpa Temp:- 10°C~ 60°C Seal:NBR+PUR Power:1.4W Explosion-proof class:CT6 Design: ...
Pressure:0.2-1.0Mpa Temp:- 10°C~ 60°C Seal:NBR+PUR Waterproof:IP65 Design: slide valve sleeve type
Pressure:02-1.0Mpa Temp:- 10°C~ 60°C Seal:NBR+PUR Waterproof:IP65 Design: slide valve sleeve type