Home Companies BOGEN PUMPS

Chemical Diaphragm Sludge Pump Air Powered Diaphragm Pump With Butterfly Valves

BOGEN PUMPS

Contact Us

[China] country

Trade Verify

Address: E 18Floor Fazhan Build No.13 Easy Huayuan Road Chancheng Area Foshan City.

Contact name:ALLSON

Inquir Now

BOGEN PUMPS

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Chemical Diaphragm Sludge Pump Air Powered Diaphragm Pump With Butterfly Valves

Country/Region china
City & Province foshan guangdong
Categories Pumps
InquireNow

Product Details

Chemical Air Operated Diaphragm Pump / Diaphragm Vacuum Pump

 

 

Air diaphragm pump(also know as a Membrane pump, air operated double diaphragm pump(AOOD) or pneumatic diaphragm pump)that uses a combination of the reciprocating action of a rubber,thermoplastic or diaphragm and suitable valves either side of the diaphragm (check valve,butterfly valves,flap valves,or any other form of shut-off valves) to pump a fluid.

 

Product Description:

 

Air Inlet

1/4-18NPTF-1

Fluid Outlet

1-11-1/2NPTF-1,Rp1-11BSP

Fluid Inlet

1-11-1/2NPTF-1,Rp1-11BSP

Max. Flow

135L/Min

Max. Head

70M

Max. Self-priming Lift (dry)

4m

Max. Air Pressure

8.3bar

Max. Particle Diameter

3mm

Max. Installation Dimension

249.5×360.5×245mm

Weight

9.5kg

Noise

<80db

 

 

Pneumatic Diaphragm Pump Advantages:

1. Explosion-proof, zero leak, simple operation.
2. Idling capability,Self suction, No complex control.
3. Diversity of material,no rotating parts,applicable to various erosive situations.
4. Diaphragm, ball and ball seat adopt imported materials with longer service life.
5. Modularization of main valve and air motor. No broken, easy to disassemble and repair.
4. Material:Cast steel,Alu,SS,PP

 

diaphragm pump offers high volume delivery even at low air pressure and a b road range of material compatibility options available.Refer to the model and option chart.The pump is provided with the modularized air motor and fluid section.

The air operated diaphragm pump alternately generates the intake fluid pressure and positive fluid pressure in the fluid chamber by using the pressure difference in the air chamber. The ball valve can ensure the forward flow of fluid.

Pump cycling will begin as air pressure is applied and it will continue to pump and keep up with the demand. It will build and maintain line pres -sure and will stop cycling once maximum line pressure is reached (dis -pensing device closed) and will resume pumping as needed.

 

A 2 5 X X - X X X - X   (model selection)

 

Form of pipe mouth:A-BSP B-NPT(F) C-Flange  

Diaphragm material:9 – Santoprene H – Hytrel   T - PTFE/Santoprene  

Ball material:9 -Santoprene H – Hytre T – PTFE A - Acetal  

Ball seat material:P/K –Polypropylene/Kynoar SS –Stainless Steel  

Pump material: SS –Stainless Steel AL –Aluminum Alloy   CI- Carbon Steel P/K –Polypropylene/Kynoar

 

 

Maximum Applied Temperature Limits (diaphragm / ball / seal material)  

 

 

Acetal ············································· 40°-         150°F        (4.4- 65.5°C)  

Santoprene······································· -40°- 225°F (-40°- 107.2°C)   ················································40°- 220°F (4.4°- 104°C)   Nitrile·················································10°- 180°F (-12°- 82°C)   Viton··················································-40°- 350°F (-40°-176.6°C)   Hytrel················································· 20°-150°F (-12°- 93°C)   Kynar·················································10°-200°F (-28.9°- 65.5°C)   Polypropylene·······································32°- 175°F (0-79.4°C)

 

 

1”  Flow diagram

 

 

 

OPERATING INSTRUCTIONS

 

  • Always flush the pump with a solvent compatible with the material being pumped if the material being pumped is subject to “setting up” when not in use for a period of time.
  • Disconnect the air supply from the pump if it is to be inactive for a few hours.
  • The outlet material volume is governed not only by the air supply but also by the material supply available at the inlet. The material supply tubing should not be too small or restrictive. Be sure not to use hose which might collapse.
  • When the diaphragm pump is used in a forced -feed (flooded inlet) situation, it is recommended that a “Check Valve” be installed at the air inlet.
  • Secure the diaphragm pump legs to a suitable surface to insure against damage by vibration.

 

 

Maintenance

 

  • Please refer to the component schematic in the assembly drawings to look up the serial numbers and names of parts and grasp the information of parts and maintenance service pack.
  • Some BSK parts are marked as "wearing parts", which can conduce to quick service and downtime reduction.
  • Service kits are divided to service two separate diaphragm pump functions: 1. AIR SECTION, 2. FLUID SECTION. The FLUID SEC -TION is divided further to match typical part MATERIAL OPTIONS.
  • Provide a clean work surface to protect sensitive internal moving parts from contamination from dirt and foreign matter during service disassembly and reassembly.
  • Keep good records of service activity and include pump in preven -tive maintenance program.
  • Before disassembling, empty captured material in the outlet man -ifold by turning the pump upside down to drain material from the pump.

 

 

 

 

 

Installation dimensions:

 

 

 

 

 

 

 

Hot Products

Chemical Resistant Air Driven Double Diaphragm Pump Self Priming Submerse Capability Pneumatic ...
Filter Press Air Operated Double Diaphragm Pump For age Treatment Air Operated Double Diaphragm Pump ...
Water Treatment Air Driven Diaphragm Pump , Chemical Diaphragm Sludge Pump What are Diaphragm Pumps? ...
Multi Functional Air Driven Double Diaphragm Pump For Ink Printing Machine 1.Product Description 1. ...
Mechanical Air Operated Reciprocating Pump , Mini Submersible Diaphragm Pump Air Operated Reciprocat...
Petrochemical Air Actuated Diaphragm Pump / Double Acting Diaphragm Pump 0.83 Mpa Air Actuated ...