Home Companies QINGDAO ENNENG MOTOR CO.,LTD.

IE5 Waterproof Surface Mounted PMSM Motor High Efficiency

QINGDAO ENNENG MOTOR CO.,LTD.

Contact Us

[China] country

Trade Verify

Address: No. 18, Xinye Road, High-Tech Zone, Qingdao,Shandong, China

Contact name:Cindy

Inquir Now

QINGDAO ENNENG MOTOR CO.,LTD.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

IE5 Waterproof Surface Mounted PMSM Motor High Efficiency

Country/Region china
City & Province qingdao shandong
Categories X-Ray Equipment
InquireNow

Product Details

High-Efficiency IE5 Waterproof Surface Mounted PMSM Motor

Energy Efficiency Standards
comply with GB30253-1 grade
Work Mode
S1
Altitude
below 1000m
Environmental Temperature
-15~+40℃
Installation Dimensions
comply with IEC standard
Control Mode
variable frequency vector control
Power Range
5.5 〜3000kw
Install Type
IMB3 IMB5 IMB35
Cooling Way
IC411 or IC416
Rated Efficiency
50,75,125,150Hz(customized as per requirement)
Insulation Class
F(H)
Optional Parts
Encoder, spiral transformer, PTC, PT100
Protection Grade
IP54(IP23 customizable)
Wiring Type
junction box (aviation plug can be customized as per requirement)
Installation
IMB3 IMB5 IMB35
Rated Voltage
380V±10%,660V±10%

Required Environment
below 1000m altitude
temperature -15〜45°C
relative humidity below 90%
 

 
Detailed pictures

The permanent magnet synchronous motor has the following characteristics:

  • Rated efficiency is 2% to 5% higher than normal asynchronous motors;
  • The efficiency rises rapidly with the increase of the load. When the load changes within the range of 25% to 120%, it maintains high efficiency. The high-efficiency operating range is much higher than that of ordinary asynchronous motors. Light-load, variable-load, and full-load all have significant energy-saving effects;
  • Power factors up to 0.95 and above, no reactive compensation required;
  • The power factor is greatly improved. Compared with asynchronous motors, the running current is reduced by more than 10%. Due to the decrease in operating current and system losses, energy-saving effects of about 1% can be achieved.
  • Low-temperature rise, high power density: 20K lower than three-phase asynchronous motor temperature rise, design temperature rise is the same and can be made into a smaller volume, saving more effective materials;
  • High starting torque and high overload capacity: according to requirements, it can be designed with high starting torque (3-5 times) and high overload capacity;
  • The variable frequency speed control system is used, which is better in dynamic response and better than that of asynchronous motors.
  • The installation dimensions are the same as the asynchronous motors currently widely used, and the design and selection are very convenient.
  • Due to the increase in power factor, the visual power of the power supply system transformer is greatly reduced, which improves the power supply capacity of the transformer, and can also greatly reduce the cost of the system cable (new project);
  • When the new project is built, all the drive systems use permanent magnet synchronous motors, the project investment is basically the same as the use of asynchronous motors, and the project can continue to obtain energy-saving benefits after the project is put into operation;

In the general industrial sector, the replacement of low-voltage(380/660/1140V) high-efficiency asynchronous motors, the system saves 5% to 30% energy, and the high-voltage(6kV/10kV) high-efficiency asynchronous motors, system saves 2% to 10%.

 

Analysis on the Application of Modern Permanent Magnet Motor Technology

 

1. Application of permanent magnet electromechanical technology to the home appliance market

The application of permanent magnet motor technology to the home appliance market is manifested in VCDDVD and computers. At present, it has gradually formed the development of industrialization, and has gradually expanded to multi-phase variable speed drives. For example, people use Inverter air conditioners use modern permanent magnet motor technology to improve the operating efficiency of the air conditioner, gradually reduce the volume of the air conditioner motor, and minimize the noise caused by the air conditioner.

 

2. Application of permanent magnet electromechanical technology in the elevator market

The permanent magnet motor variable speed system has been used in the elevator market for almost 10 years. For example, by using a low-speed rare earth permanent magnet motor as the elevator traction machine, the use of rare earth permanent magnet motor can save elevator use 20 % of electric energy. Modern permanent magnet motors are usually used in the field of variable-speed drive systems with large load changes and high speed adjustment requirements.

 

3. Application of permanent magnet electromechanical technology in industrial and mining enterprises

With the development of permanent magnet motors, large torque permanent magnet motors have been well developed, especially the successful launch of permanent magnet variable frequency motors on the market has given heavy industrial and mining enterprises new choices. Since the output torque of the permanent magnet motor is large enough, the use of the mechanical transmission is reduced and the speed is controllable. It can run at low speeds. Therefore, the application of the fluid coupling is eliminated, which saves the cost of purchasing related equipment and the maintenance of the above two equipment, which reduces the safety risk, so the permanent magnet variable frequency motor is very popular in many industrial and mining enterprises. Because of its variable frequency speed regulation function, it provides a strong guarantee for users to improve production efficiency and save electric energy. Therefore, modern permanent magnet variable frequency motors are a necessary choice for industrial and mining enterprises to upgrade their equipment in the future.

The rotor magnetic circuit structure of the permanent magnet synchronous motor is different, so the operation characteristics and control system of the motor are also different. According to the different positions of the permanent magnets on the rotor, permanent magnet synchronous motors can be mainly divided into the surface type and interior type. In the surface-type permanent magnet synchronous motor, the permanent magnets are usually tile-shaped and located on the outer surface of the rotor core. The important feature of this motor is that the main inductances of the straight and orthogonal axes are equal; the interior permanent magnet is located inside the rotor, and there is a pole piece made of ferromagnetic material between the outer surface of the permanent magnet and the inner circle of the stator core, which can protect the permanent magnet. The important feature of this permanent magnet motor is that the main inductances of the straight and quadrature axes are not equal. Therefore, the performance of these two motors is different.

 

I. Overview

The motor is excited by rare earth neodymium iron boron permanent magnet materials and is supplied with a permanent magnet special frequency converter. It has the characteristics of large starting torque, wide speed range, compact structure, small size, lightweight, low noise, high power factor, and high efficiency. It is an ideal power choice for high-efficiency and energy-saving air compressors. The technical requirements and parameters are as follows:

 

Rated speed (r/min)3000,3600,1000
Frequency(Hz)150,200,240
Power range(kW)7.5~200
Cooling typeIC411(Self-fan cooling),IC416

 

1. The motor can operate normally under the following conditions:

1.1 The ambient temperature does not exceed 40℃;

1.2 Relative humidity ≤90%;

1.3 The altitude does not exceed 1000m.

2. The rated voltage of the motor is 380V, also according to user requirements.

3. The reference work system of the motor: S1.

4. Insulation grade: F grade.

5. Protection level: IP55.

6. Motor structure and installation type: B3, B35.

7. The motor outlet is located on the top of the base, or it can be located on the right or left of the base according to user requirements.

8. Motor service factor: 1.15, 1.2 (or as per technical agreement).

 

II. Inspection

1. Before use, please carefully check the appearance of the motor for damage during transportation, and check whether the nameplate parameters (power, voltage, speed, etc.) are consistent with the order.

2. Check whether the fasteners of the motor are loose.

3. Turn the motor shaft by hand to see if there is any jamming.

 

III. Operation and use

1. Before the motor is energized, confirm the rotation direction of the motor, and check whether the mechanical installation and electrical connection are safe and reliable.

2. If abnormal noise or vibration is found in the motor during operation, please stop the operation immediately and cut off the power supply. Check the motor and compressor, and put it into operation again after troubleshooting.

3. If the temperature rise of the motor is found to be abnormal during operation, please stop the motor and cut off the power immediately, check the motor and the compressor, and then put it into use again after troubleshooting.

Hot Products

OEM ODM Service Low Speed 3 Phase PMSM Motor Without Gearbox What Is The Permanent Magnet Synchronou...
Energy Saving Low Starting Current 3 Phase PMSM Motor For Belt Conveyor What Is The Permanent Magnet ...
Brushless AC 3 Phase Variable Frequency Drive PMSM Motor For Belt Conveyor What Is The Permanent ...
Eco-Friendly Direct Drive Gearless Neodymium Magnet 3 Phase PMSM Motor What Is The Permanent Magnet ...
High-Efficiency Water Cooled PMSM Permanent Magnet Electric Motor Energy Efficiency Standards comply ...
Maintenance Free Energy Saving 5.5kw-3000kw Neodymium Magnet PMAC Motor What Is The Permanent Magnet ...