Home Companies Changsha Zhinian Automation Equipment Co., Ltd.

Transistor Output Omron PLC CP1H CPU Unit 24V CP1H-X40DT-D

Changsha Zhinian Automation Equipment Co., Ltd.

Contact Us

[China] country

Trade Verify

Address: Room1504,6th Building,GaoSheng Times Square,No.798 zhongYiyi Road,Yuhua District,Changsha City,Hunan,China

Contact name:Julia

Inquir Now

Changsha Zhinian Automation Equipment Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Transistor Output Omron PLC CP1H CPU Unit 24V CP1H-X40DT-D

Country/Region china
City & Province changsha hunan
Categories Chargers
InquireNow

Product Details

Omron CP series CP1H CPU Unit CP1H-X40DT-D Programmable Controllers

Description

Omron PLC Control Logic CP1H-X40DT-D

  • Extended Product Type: CP1H
  • Product ID: CP1H-X40DT-D
  • OMRON Type Designation : CP1H
  • Description: CONTROL LOGIC 24 IN 16 OUT 24V

Features

• Pulse output for 4 axes. Advanced power for high-precision positioning control.
• High-speed counters. Differential phases for 4 axes. Easily handles multi-axis control with a single unit.
• Eight interrupt inputs are built in. Faster processing of approximately 500 instructions speeds up the entire system.
• Serial communications. Two ports. Select Option Boards for either RS-232C or RS-485 communications.
• Ethernet Communications. Enabled by using an Option Board. Two ports can be used as an Ethernet port to perform. Ethernet communications between the CP1H and a host computer.
• Built-in Analog I/O. XA CPU Units provide 4 input words and 2 output words.
• USB Peripheral Port. Another standard feature.
• The structured text (ST) language. Makes math operations even easier.
• Can be used for the CP1W series and CJ series Unit. The extendibility of it is preeminently good.
• LCD displays and settings. Enabled using Option Board.

International Standards

• The standards are abbreviated as follows: U: UL, U1: UL (Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus,
UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, KC: KC Registration, and CE: EU Directives.
• Contact your OMRON representative for further details and applicable conditions for these standards.

Specification

  • Power supply: DC power supply
  • Output method :Transistor output (sinking)
  • Inputs : 24
  • Outputs: 16
  • Standards : UC1, N, L, CE, KC

 

General Specifications

 

TypeAC power supply modelsDC power supply models
ModelCP1H-[][][]-ACP1H-[][][]-D
Power supply100 to 240 VAC 50/60 Hz24 VDC
Operating voltage range85 264 VAC20.4 to 26.4 VDC
(with 4 or more Expansion Units and
Expansion I/O Units: 21.6 to 26.4 VDC)
Power consumption100 VA max. (CP1H-[][][]-A)50 W max. (CP1H-[][][]-D)
Inrush current *100 to 120 VAC inputs:
20 A max. (for cold start at room
temperature)
8 ms max.
200 to 240 VAC inputs:
40 A max. (for cold start at room
temperature),
8 ms max.
30 A max. (for cold start at room
temperature)
20 ms max.
External power supply300 mA at 24 VDCNone
Insulation resistance20 MΩ min. (at 500 VDC) between the
external AC terminals and GR terminals
No insulation between primary and secondary
for DC power supply
Dielectric strength2,300 VAC at 50/60 Hz for 1 min between
the external AC and GR terminals, leakage
current: 5 mA max.
No insulation between primary and secondary
for DC power supply
Noise immunityConforms to IEC 61000-4-4. 2 kV (power supply line)
Vibration resistanceConforms to JIS C60068-2-6. 10 to 57 Hz, 0.075-mm amplitude, 57 to 150 Hz,
acceleration: 9.8 m/s2 in X, Y, and Z directions for 80 minutes each. Sweep time:
8 minutes × 10 sweeps = total time of 80 minutes)
Shock resistanceConforms to JIS C60068-2-27. 147 m/s2 three times each in X, Y, and Z directions
Ambient operating
temperature
0 to 55°C
Ambient humidity10% to 90% (with no condensation)
Ambient operating
environment
No corrosive gas
Ambient storage
temperature
-20 to 75°C (Excluding battery.)
Power holding time10 ms min.2 ms min.

 

Note: The above values are for a cold start at room temperature for an AC power supply, and for a cold start for a DC
power supply.
• A thermistor (with low-temperature current suppression characteristics) is used in the inrush current control
circuitry for the AC power supply. The thermistor will not be sufficiently cooled if the ambient temperature is
high or if a hot start is performed when the power supply has been OFF for only a short time. In those cases
the inrush current values may be higher (as much as two times higher) than those shown above. Always allow
for this when selecting fuses and breakers for external circuits.
• A capacitor charge-type delay circuit is used in the inrush current control circuitry for the DC power supply. The
capacitor will not be charged if a hot start is performed when the power supply has been OFF for only a short
time, so in those cases the inrush current values may be higher (as much as two times higher) than those
shown above.

Performance Specifications

 

TypeCP1H-XA
CPU Units
CP1H-X
CPU Units
CP1H-Y CPU Units
ModelsCP1H-XA[][][]-[]CP1H-X[][][]-[]CP1H-Y[][][]-[]
Control methodStored program method
I/O control methodCyclic scan with immediate refreshing
Program languageLadder diagram
Function blocksMaximum number of function block definitions: 128 Maximum number of instances: 256
Languages usable in function block definitions: Ladder diagrams, structured text (ST)
Instruction length1 to 7 steps per instruction
InstructionsApprox. 500 (function codes: 3 digits)
Instruction execution timeBasic instructions: 0.10 μs min. Special instructions: 0.15 μs min.
Common processing time0.7 ms
Program capacity20K steps
Number of tasks288 (32 cyclic tasks and 256 interrupt tasks)
 Scheduled
interrupt tasks
1 (interrupt task No. 2, fixed)
Input interrupt
tasks
8 (interrupt task No. 140 to 147, fixed)6 (interrupt task No. 140 to 145, fixed)
(Interrupt tasks can also be specified and executed for high-speed counter interrupts.)
Maximum subroutine
number
256
Maximum jump number256
I/O areas
*
Input bits272bits (17 words): CIO 0.00 to 16.15
Output bits272bits (17 words): CIO 100.00 to 116.16
Built-in Analog
Inputs
CIO 200 to CIO 203---
Built-in Analog
Outputs
CIO 210 to CIO 211---
Serial PLC
Link Area
1,440 bits (90 words): CIO 3100.00 to CIO 3189.15 (CIO 3100 to CIO 3189)
Work bits8,192 bits (512 words): W0.00 to W511.15 (W0 to W511)
CIO Area: 37,504 bits (2,344 words): CIO 3800.00 to CIO 6143.15 (CIO 3800 to CIO 6143)
TR Area16 bits: TR0 to TR15
Holding Area8,192 bits (512 words): H0.00 to H511.15 (H0 to H511)
AR AreaRead-only (Write-prohibited): 7168 bits (448 words): A0.00 to A447.15 (A0 to A447)
Read/Write: 8192 bits (512 words): A448.00 to A959.15 (A448 to A959)
Timers4,096 bits: T0 to T4095
Counters4,096 bits: C0 to C4095
DM Area32 Kwords: D0 to D32767
Data Register Area16 registers (16 bits): DR0 to DR15
Index Register Area16 registers (32 bits): IR0 to IR15
Task Flag Area32 flags (32 bits): TK0000 to TK0031
Trace Memory4,000 words (500 samples for the trace data maximum of 31 bits and 6 words.)
Memory CassetteA special Memory Cassette (CP1W-ME05M) can be mounted.
Note: Can be used for program backups and auto-booting.
Clock functionSupported. Accuracy (monthly deviation):
-4.5 min to -0.5 min (ambient temperature: 55°C),
-2.0 min to +2.0 min (ambient temperature: 25°C),
-2.5 min to +1.5 min (ambient temperature: 0°C)
Communications functionsOne built-in peripheral port (USB 1.1): For connecting Support Software only.
A maximum of two Serial Communications Option Boards can be mounted.
A maximum of two Ethernet Option Boards can be mounted. When using CP1W-CIF41
Ver.1.0, one Ethernet Option Board can be mounted.
Memory backupFlash memory: User programs, parameters (such as the PLC Setup), comment data,
and the entire DM Area can be saved to flash memory as initial values.
Battery backup: The Holding Area, DM Area, and counter values (flags, PV) are backed up
by a battery.
Battery service life5 years at 25°C. (Use the replacement battery within two years of manufacture.)
Built-in input terminals40 (24 inputs, 16 outputs)20 (12 inputs, 8 outputs)
Line-driver inputs: Two axes for phases A,
B, and Z
Line-driver outputs: Two axes for CW and
CCW
Number of connectable
Expansion (I/O) Units
CP Expansion I/O Units: 7 max.; CJ-series Special I/O Units or CPU Bus Units: 2 max.
Max. number of I/O points320 (40 built in + 40 per Expansion (I/O)
Unit × 7 Units)
300 (20 built in + 40 per Expansion (I/O)
Unit × 7 Units)
Interrupt inputs8 inputs (Shared by the external interrupt
inputs (counter mode) and the quick-
response inputs.)
6 inputs (Shared by the external interrupt
inputs (counter mode) and the quick-
response inputs.)
Interrupt input counter
mode
8 inputs (Response frequency: 5 kHz
max. for all interrupt inputs), 16 bits
Up or down counters
6 inputs (Response frequency: 5 kHz max.
for all interrupt inputs), 16 bits
Up or down counters
Quick-response inputs8 points (Min. input pulse width: 50 μs max.)6 points (Min. input pulse width: 50 μs max.)
Scheduled interrupts1
High-speed counters4 inputs:
Differential phases (4x), 50 kHz or
Single-phase (pulse plus direction, up/
down, increment), 100 kHz
Value range: 32 bits, Linear mode or ring
mode
Interrupts: Target value comparison or
range comparison
2 inputs:
Differential phases (4x), 500 kHz or Single-
phase, 1 MHz and
2 inputs:
Differential phases (4x), 50 kHz or Single-
phase (pulse plus direction, up/down,
increment), 100 kHz
Value range: 32 bits, Linear mode or ring
mode
Interrupts: Target value comparison or
range comparison
Pulse
outputs
(models
with
transistor
outputs
only)
Pulse outputsTrapezoidal or S-curve acceleration and
deceleration (Duty ratio: 50% fixed)
4 outputs, 1 Hz to 100 kHz (CCW/CW or
pulse plus direction)
Trapezoidal or S-curve acceleration and
deceleration (Duty ratio: 50% fixed)
2 outputs, 1 Hz to 1 MHz (CCW/CW or pulse
plus direction)
2 outputs, 1 Hz to 100 kHz (CCW/CW or
pulse plus direction)
PWM outputsDuty ratio: 0.0% to 100.0% (Unit: 0.1%)
2 outputs, 0.1 to 6553.5 Hz (Accuracy: ±5% at 1 kHz)
Built-in analog I/O terminals4 analog inputs and
2 analog outputs
None
Analog control1 (Setting range: 0 to 255)
External analog input1 input (Resolution: 1/256, Input range: 0 to 10 V), not isolated

Hot Products

CJ1W-EIP21 410mA Automation Omron PLC Programming Equipment PLC Feature Open to any communication ...
CJ1W-PA202 Automation Omron PLC Industrial Electrical Equipment Original Omron Automation Equipment ...
CJ1W-II101 Automation Omron PLC Industrial Electrical Equipment Original Omron Automation Equipment ...
CJ1W-CT021 High Speed Omron CJ1W PLC Counter Unit Special I / O Units roduct Details Omron PLC High...
CJ1W-DA021 High Speed Omron CJ1 PLC Counter Unit Special I / O Units Product Details Omron PLC High...
CJ1W-OD232 Automation Omron PLC Industrial Electrical Equipment Original Omron Automation Equipment ...