NEW&ORIGINAL OMRON PLC CP1H-XA40DR-A PLC Controller Price List

Description

• Pulse output for 4 axes. Advanced power for high-precision positioning control.

• High-speed counters. Differential phases for 4 axes. Easily handles multi-axis control with a single unit.

• Eight interrupt inputs are built in. Faster processing of approximately 500 instructions speeds up the entire system.

• Serial communications. Two ports. Select Option Boards for either RS-232C or RS-485 communications.

• Ethernet Communications. Enabled by using an Option Board. Two ports can be used as an Ethernet port to perform. Ethernet communications between the CP1H and a host computer.

• Built-in Analog I/O. XA CPU Units provide 4 input words and 2 output words.

• USB Peripheral Port. Another standard feature.

• The structured text (ST) language. Makes math operations even easier.

• Can be used for the CP1W series and CJ series Unit. The extendibility of it is preeminently good.

• LCD displays and settings. Enabled using Option Board.

 

 

General Specifications

 

TypeAC power supply modelsDC power supply models
ModelCP1H-[][][]-ACP1H-[][][]-D
Power supply100 to 240 VAC 50/60 Hz24 VDC
Operating voltage range85 264 VAC20.4 to 26.4 VDC
(with 4 or more Expansion Units and
Expansion I/O Units: 21.6 to 26.4 VDC)
Power consumption100 VA max. (CP1H-[][][]-A)50 W max. (CP1H-[][][]-D)
Inrush current *100 to 120 VAC inputs:
20 A max. (for cold start at room
temperature)
8 ms max.
200 to 240 VAC inputs:
40 A max. (for cold start at room
temperature),
8 ms max.
30 A max. (for cold start at room
temperature)
20 ms max.
External power supply300 mA at 24 VDCNone
Insulation resistance20 MΩ min. (at 500 VDC) between the
external AC terminals and GR terminals
No insulation between primary and secondary
for DC power supply
Dielectric strength2,300 VAC at 50/60 Hz for 1 min between
the external AC and GR terminals, leakage
current: 5 mA max.
No insulation between primary and secondary
for DC power supply
Noise immunityConforms to IEC 61000-4-4. 2 kV (power supply line)
Vibration resistanceConforms to JIS C60068-2-6. 10 to 57 Hz, 0.075-mm amplitude, 57 to 150 Hz,
acceleration: 9.8 m/s2 in X, Y, and Z directions for 80 minutes each. Sweep time:
8 minutes × 10 sweeps = total time of 80 minutes)
Shock resistanceConforms to JIS C60068-2-27. 147 m/s2 three times each in X, Y, and Z directions
Ambient operating
temperature
0 to 55°C
Ambient humidity10% to 90% (with no condensation)
Ambient operating
environment
No corrosive gas
Ambient storage
temperature
-20 to 75°C (Excluding battery.)
Power holding time10 ms min.2 ms min.

 

Note: The above values are for a cold start at room temperature for an AC power supply, and for a cold start for a DC
power supply.
• A thermistor (with low-temperature current suppression characteristics) is used in the inrush current control
circuitry for the AC power supply. The thermistor will not be sufficiently cooled if the ambient temperature is
high or if a hot start is performed when the power supply has been OFF for only a short time. In those cases
the inrush current values may be higher (as much as two times higher) than those shown above. Always allow
for this when selecting fuses and breakers for external circuits.
• A capacitor charge-type delay circuit is used in the inrush current control circuitry for the DC power supply. The
capacitor will not be charged if a hot start is performed when the power supply has been OFF for only a short
time, so in those cases the inrush current values may be higher (as much as two times higher) than those
shown above.

Hot Products

CJ1W-EIP21 410mA Automation Omron PLC Programming Equipment PLC Feature Open to any communication ...
CJ1W-PA202 Automation Omron PLC Industrial Electrical Equipment Original Omron Automation Equipment ...
CJ1W-II101 Automation Omron PLC Industrial Electrical Equipment Original Omron Automation Equipment ...
CJ1W-CT021 High Speed Omron CJ1W PLC Counter Unit Special I / O Units roduct Details Omron PLC High...
CJ1W-DA021 High Speed Omron CJ1 PLC Counter Unit Special I / O Units Product Details Omron PLC High...
CJ1W-OD232 Automation Omron PLC Industrial Electrical Equipment Original Omron Automation Equipment ...