Home Companies Suzhou Delfino Environmental Technology Co., Ltd.

Digital Disinfectant Ozone Transmitter Online Monitoring For Water Treatment IP66

Suzhou Delfino Environmental Technology Co., Ltd.

Contact Us

[China] country

Trade Verify

Address: Suzhou Xupai Road No.3

Contact name:Yuki Fu

Inquir Now

Suzhou Delfino Environmental Technology Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Digital Disinfectant Ozone Transmitter Online Monitoring For Water Treatment IP66

Country/Region china
City & Province suzhou
Categories Water Treatment
InquireNow

Product Details

 

Digital Disinfectant Ozone Transmitter Online Monitoring For Water Treatment IP66

 

 

DRFN’s DUC2-OZ-H ozone analyzer is a single parameter instrument. It is designed to monitor ozone(O3) in drinking water, industrial cooling, and rinse water, wastewater, or other freshwater.

 

Ozone is widely used in the drinking water and wastewater industries. It is also used as a disinfectant in cooling towers and municipal wastewater treatment plants. Ozone is an effective bactericide that does not form any harmful Disinfection By Products (DBP) like many chlorine products do.

 

 

Advantages Of The Ozone Transmitter
 

  • Protection level IP66
  • RS485 communication, support Modbus protocol
  • Provide wide-voltage AC or DC power supply mode
  • Support a variety of installation methods
  • Time and historical data recording functions
  • 128*64 black and white graphic dot matrix screen
  • 2 settable 0/4~20mA active current loop outputs
  • 2 settable SPST alarm relays

 
Applications Of The Ozone Transmitter

 

Water plant disinfection process and chlorination control, pipe network and secondary water supply water quality safety monitoring;

 

Disinfection process control for water production in food, beverage, dairy and pharmaceutical production processes;

 

Other occasions for ozone disinfection of water.
 

 

Product Parameters
 

Product NameOzone Transmitter
Product Model

DUC2-OZ-H

Software Version

DRFN Ozone Analysis software V1.0

Display Range

0.01mg/L~100g/L

Resolution

0.01mg/L

Relay Control

2 settable SPST relays, the max. load 3A/250VAC

Analog Current Output

2 settable 0/4~20mA active current loop output max. load 1000Ω

Communication Method

Two-wire RS485 interface, MODBUS RTU; support JSON text data format

Display Screen

128*64 LCD, adjustable backlight mode, adjustable display rate

Time History/Data Record

Year/month/day/hour/min/second, record 14000 historical data, record interval can be set between 1~999 minutes

Maintenance Records

Last 100 times

Protection Grade

IP66

Operating Environment

0~60℃, relative humidity less than 95%

Storage Environment

-20~70℃, relative humidity less than 55%

Shell Material

Enhanced ABS

Dimensions

144*144*120mm (hole size 138*138 mm)

Mounting Method

Wall mounting, pipe clamping, panel installation

Power Supply

18~36V DC or 100~240V AC

Weight

800g

Power Consumption

7W

Electrical Interface

The back end of the instrument reserved 3 M12*1.5 gland, line diameter 3~6.5 mm

 

 
 
The Suitable Ozone Sensors Recommendation
 

  • Model: OZ1.2
  • pH range: 2~11
  • Pressure range: 0~1 bar
  • Temperature range: 0~45℃
  • Integrated automatic temperature compensation
  • Response time: T90 about 15s
  • Flow rate: about 30 l/h, low flow-dependence
  • Shaft length: standard 175 mm
  • Connection: Modbus RTU with M12 male
  • Material: PVC, semipermeable membrane

 

Type

Measuring range:
ppm

Resolution:

ppm

Output signalPower supplyItem number
OZ1.2H-M0c0.005~2.0000.001Modbus RTU

9~30 VDC

20~56 mA

3426530
OZ1.2N-M0c0.05~20.000.013426531

 


 

  • Model: OZ7
  • pH range: 2~11
  • Pressure range: 0~1 bar
  • Temperature range: 0~45℃
  • Integrated automatic temperature compensation
  • Response time: T90 about 50s
  • Flow rate: about 30 l/h, low flow-dependence
  • Shaft length: standard 175 mm
  • Connection: Modbus RTU with M12 male
  • Material: PVC-U, stainless steel 1.4571
Type

Measuring range:
ppm

Resolution:

ppm

Output signalPower supplyItem number
OZ7H-M0c0.005~2.0000.001Modbus RTU

9~30 VDC

20~56 mA

3226040
OZ7N-M0c0.05~20.000.013226041

 


  • Model: OZ10
  • pH range: 2~11
  • Pressure range: 0~1 bar
  • Temperature range: 0~45℃
  • Integrated automatic temperature compensation
  • Response time: T90 about 15s
  • Flow rate: about 30 l/h, low flow-dependence
  • Shaft length: standard 175 mm
  • Connection: Modbus RTU with M12 male
  • Material: PVC, semipermeable membrane

 

Type

Measuring range:
ppm

Resolution:

ppm

Output signalPower supplyItem number
OZ10H-M0c0.005~2.0000.01Modbus RTU

9~30 VDC

20~56 mA

3426410
OZ10N-M0c0.05~20.000.013426411

 
 













Hot Products

Analog Two SPST Relays IP66 PH ORP Controller For Water Treatment Monitoring The APX1-C1A/C1D PH ORP ...
Two 0/4~20mA Outputs PH ORP Transmitter For Industrial Process Monitoring The APX1-C2A/C2D PH ORP ...
Two SPST Relays RS485 Modbus PH ORP Meter For Dosing Control The pH ORP controller APX1-G2A is an ...
Data Recording 3.2 Inch Screen Onlin PH Controller For Water Treatment Monitoring The APX2-C3A/C3D ...
Differential Signal RS485 PH Tester With Historical Data Recording Function The APX2-G3A/G3D pH ORP ...
IP66 ABS pH analyzer For Industrial Dosing Control for Industrial process monitoring The APX1-L1 PH ...