Home Companies Suzhou Delfino Environmental Technology Co., Ltd.

220V Amperometric Chlorine Dioxide Water Quality Transmitter Drinking Water 800g

Suzhou Delfino Environmental Technology Co., Ltd.

Contact Us

[China] country

Trade Verify

Address: Suzhou Xupai Road No.3

Contact name:Yuki Fu

Inquir Now

Suzhou Delfino Environmental Technology Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

220V Amperometric Chlorine Dioxide Water Quality Transmitter Drinking Water 800g

Country/Region china
City & Province suzhou
Categories Measuring & Analysing Instrument Processing Services
InquireNow

Product Details

 

220V Amperometric Chlorine Dioxide Transmitter For Drinking Water 800g

 

Introduction 

 

A large number of experimental studies have shown that chlorine dioxide is a safe and non-toxic disinfectant with no "three-causing" effects (carcinogenic, teratogenic, and mutagenic). At the same time, it does not react with organic substances during the disinfection process.

 

The ADS2-U3A-CD10 chlorine dioxide analyzer water quality transmitter is a single parameter analyzer,specially used in the disinfection industry. Each chlorine dioxide instrument is connected to DRFN's chlorine dioxide sensors to realize the measurement of chlorine dioxide disinfectants.

 

 

Advantages Of Chlorine Dioxide Transmitter

 

1. The protection grade of the chlorine dioxide controller shell is IP66, which can effectively isolate the pollution and corrosive gas intrusion from the external environment.

 

2. All the configuration entered by the user is kept indefinitely, even if there is no power, the data will not be lost.

 

3. 128*64 black and white graphic dot matrix screen, and the display backlight provides always on and energy-saving mode selection.

 

4.  It has time and historical data recording functions to meet higher data management requirements.

 

5. The user can use the operation panel on the front of the controller to calibrate the sensor and set various parameters that need to be output.

 

6. Two settable 0/4~20mA active current loop outputs, and each current output allows the user to specify what measurement value it represents. 

 

7. The controller has two settable SPST relays. The setting objects include alarms for the high and low values of the measurement parameters, the control of the cleaning cycle of the sensor. The warning of the working environment temperature of the instrument.

 

 

Applications Of Chlorine Dioxide Transmitter

 

Online analysis of chlorine dioxide in municipal tap water, drinking water, food, beverages, and other water sources and water supply pipe networks;

 

Online analysis of circulating cooling water and swimming pool water, as well as sewage and wastewater disinfection and chemical addition control.

 

 

Parameters Of Chlorine Dioxide Transmitter

 

Product NameChlorine Dioxide Transmitter 
Product Model

ADS2-U3A-CD10

Software Version

DRFN chlorine dioxide Analysis software V1.0

Display Range

0.00-200.00mg/L

Resolution

0.001 mg/L

Accuracy

Better than 0.15% of the measuring range

Stability

0.05% of the measuring range every 24 hours, no accumulation

Repeatability

Better than 0.1% of the measuring range

Relay Control

2 settable SPST relays, the max. load 3A/250VAC

Sensor Self-diagnosis

screen image and buzzer prompt

Analog Current Output

2 settable 0/4~20mA active current loop output max. load 1000Ω

Communication Method

RS485, MODBUS RTU; support JSON text data format

Display Screen

128*64 LCD

Time History/Data Record

Year/month/day/hour/min/second, record 14000 historical data

Protection Grade

IP66

Operating Environment

0~60℃, relative humidity less than 95%

Storage Environment

-20~70℃, relative humidity less than 55%

Shell Material

Enhanced ABS

Dimensions

144*144*120mm (hole size 138*138 mm)

Mounting Method

Wall mounting, pipe clamping, panel installation

Power Supply

100~240V AC

Weight

800g

Power Consumption12W

 

 
The Matching Chlorine Dioxide Recommendation
 
  • Model: CD10
  • pH range: 1~12
  • Pressure range: 0~1 bar
  • Temperature range: 0~50℃
  • Response time: T90 about 60 s
  • Integrated automatic temperature compensation
  • Flow rate: about 30 l/h, low flow-dependence
  • Shaft length: standard 175 mm, and up to 220 mm in length (mA-Version)
  • Connection: 2-pole terminal, M12 male
  • Material: PVC-U, semipermeable membrane

 

Type

Measuring range:

ppm

Resolution:

ppm

Output signalPower supplyItem number
CD10MA20.005~2.0000.0014~20 mA

12~30 VDC

RL 50Ω~900Ω

 

3426205
CD10MA50.05~5.000.013426206
CD10MA100.05~10.000.013426207
CD10MA200.05~20.000.013426208

CD10MA2-M12

0.005~2.000

0.001

3426230

CD10MA5-M12

0.05~5.00

0.01

3426231

CD10MA10-M12

0.05~10.00

0.01

3426232

CD10MA20-M12

0.05~20.00

0.01

3426233

 

Hot Products

Analog Two SPST Relays IP66 PH ORP Controller For Water Treatment Monitoring The APX1-C1A/C1D PH ORP ...
Two 0/4~20mA Outputs PH ORP Transmitter For Industrial Process Monitoring The APX1-C2A/C2D PH ORP ...
Two SPST Relays RS485 Modbus PH ORP Meter For Dosing Control The pH ORP controller APX1-G2A is an ...
Data Recording 3.2 Inch Screen Onlin PH Controller For Water Treatment Monitoring The APX2-C3A/C3D ...
Differential Signal RS485 PH Tester With Historical Data Recording Function The APX2-G3A/G3D pH ORP ...
IP66 ABS pH analyzer For Industrial Dosing Control for Industrial process monitoring The APX1-L1 PH ...