Home Companies Suzhou Delfino Environmental Technology Co., Ltd.

Chlorite Sensor Water Quality Probe Amperometric 3 Electrode

Suzhou Delfino Environmental Technology Co., Ltd.

Contact Us

[China] country

Trade Verify

Address: Suzhou Xupai Road No.3

Contact name:Yuki Fu

Inquir Now

Suzhou Delfino Environmental Technology Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Chlorite Sensor Water Quality Probe Amperometric 3 Electrode

Country/Region china
City & Province suzhou
Categories Temperature Instruments
InquireNow

Product Details

 

Chlorite Sensor Water Quality Probe Amperometric 3 Electrode For Water Treatment

 

 

Descriptions

 

The measuring system of the water quality probe chlorite sensor MST1 is membrane-covered, amperometric 3-electrode system. It is used for the measurement of chlorite.The chlorite from acid/chlorite process, chlorine/chlorite-process chlorite/oxidant-process.You can calibrate the sensor via analytical determination of chlorite at the controller.

 

The pH range of the chlorite probe is 6 ~ 9pH. The measuring water temperature range is 0 ~ 40℃. The flow rate of the water quality sonde is about 15-30L/h.The membrane lifetime is normally 1 year (depending on water quality), the electrolyte should change every 3 - 6 months.

 

 

Specifications
 

Product NameChlorite sensor water quality probe
Product ModelChlorite sensor MST1
pH Range6 ~ 9
Pressure Range 0 ~ 5bar, without outgassing, no pressure surges or fluctuations
Temperature Range

0~ 40℃ 

Run-in-time

First start-up about 24h

Response Time
T90 1min.

Connection

Modbus RTU with M12 male

Shaft Length

standard 175 mm, and up to 220 mm in length (mA-Version)

Material

PVC, Peek, stainless steel 1.4571, Microporous hydrophilic membrane,

Flow Rate

30 L/h

Absence Of Disinfectant
Max. 24 h

 

 

Applications Of Chlorite Sensor

 

Drinking water, swimming pool water, service water, process water.

 

 
Advantages Of Chlorite Sensor
 
The water quality probe chlorite sensor MST1 is used for the measurement of chlorite.No cross-interference to chlorine dioxide, chlorine, and chlorate. But corrosion inhibitors can lead to measuring errors, stabilizers for water hardness can lead to measuring errors.
 
The temperature compensation of chlorite sensor MST1 water quality probe is automatical, by an integrated temperature sensor. Sudden temperature changes must be avoided.
 

 

 

Scope Of Supply

 

Water quality probe chlorite sensor MST1: sensor, membrane cap, electrolyte.

 

 

Ordering Data:
 

Type

Measuring range(ppm)

Resolution(ppm)

Output signal

Power supply

Item number

MST1H-M0c

0.05 ~ 2.00

0.001

Modbus RTU

9 ~ 30 V DC
20 ~ 56 mA

3326410

MST1N-M0c

0.05 ~ 2.00

0.01

3326411

 

If you are interested in the water quality sonde chlorite sensor MST1, please contact us.

 
About Chlorite
 
Chlorite is a disinfection by-product generally caused by the breakdown of sodium hypochlorite or chlorine dioxide disinfectants. As a by-product of the treatment of water with chlorine dioxide and in potable water generation, chlorite is subject to monitoring requirements in many countries.
 

 

Hot Products

Analog Two SPST Relays IP66 PH ORP Controller For Water Treatment Monitoring The APX1-C1A/C1D PH ORP ...
Two 0/4~20mA Outputs PH ORP Transmitter For Industrial Process Monitoring The APX1-C2A/C2D PH ORP ...
Two SPST Relays RS485 Modbus PH ORP Meter For Dosing Control The pH ORP controller APX1-G2A is an ...
Data Recording 3.2 Inch Screen Onlin PH Controller For Water Treatment Monitoring The APX2-C3A/C3D ...
Differential Signal RS485 PH Tester With Historical Data Recording Function The APX2-G3A/G3D pH ORP ...
IP66 ABS pH analyzer For Industrial Dosing Control for Industrial process monitoring The APX1-L1 PH ...