Product Details

Higher stability and reliability Automated Perimetry Machine

 

 

System configuration of Automated Perimetry Machine

 

1. The hardware of the vision instrument is composed of computer automatic vision instrument host, wireless keyboard and wireless mouse.

 

2. Perimeter (system) software consists of the following modules:
    Patient information input module;
    Data analysis and processing software module;
    File management module;
   Output print module.

 

3. computer and operating system configuration requirements

    CPU: Intel 1620 or above;

    Memory: 512m or more;

    Hard disk: more than 300 gigabytes;

    Monitor: above 15 ";

    Graphics card: integrated graphics card;

    Operating system: Windows 7 and above.

 

Specifications:

Basic specification

small size Automated Perimetry Machine

Inspection range

90°

Inspection distance

30cm

Background light brightness

White 31.5asb

Visual target brightness

1asb--- -10000asb

Visual target size

GoldmannIII

Visual target interval time

200ms

Visual target interval time

Standard or adjustment according to patient reflection

Threshold test model

Center5-°16, center10° -68, 24 -2, 30-2, 30° -60° nasal step

Upper Threshold test model

30°- 40, 30°-76, P-60, 60°-81, 60°-120,190°-135 nasal side

Special detection strategy

Esterman monocular, Esterman binocular . user- customized test, 150P driver monocular fast detection, 150P driver monocular standard detection , upper 36 detection, blind spot detection,150horizontal straightness detection

Pupil size test

Automatic

Fixation monitoring

Blind spot monitoring , eye position eye position deviation alarm, eye deviation curve

Environment light detection

Automatic

Analysis software

Reliability analysis , single vision report, triple vision report, GPA half vision analysis, GPA glaucoma developing analysis , VFI vision index analysis

Operation system

Win7 above

 

Feature

Automated Perimetry Machine

1. Comprehensive real-time monitoring, heiji-krakau physiological blind spot monitoring. Gaze tracking/head position tracking, automatic measurement of pupil diameter, reduce the impact of pupil effect on visual field detection.

2. Personalized design, accurate clinical analysis, accurate and rapid examination strategy.

3. Under international Goldman standard, providing a variety of calssic test procedures and report analysis.

 

 

BIO-1000 fully automatic computer visual instrument absorbs the advantages of international advanced models, integrated acoustic, optical, mechanical and electrical technology, using large-scale integrated circuit design, using projection mode, using the international general random detection mode for visual marking, inspection range is wide (0-90°).Automatic vision machine adopts high-end computer configuration, compared with the domestic similar products, stability, reliability is higher.Support WindowsXP, Win7 platform, beautiful software interface, simple operation, easy to learn and use.Comprehensive software examination procedures and multi-report analysis according to international standards provide auxiliary diagnosis for diseases associated with visual impairment.

 

Features of Automated Perimetry Machine

 

1. Comprehensive real-time monitoring, black market Krakau physiological blind spot monitoring.Eye tracking/head tracking, automatic measurement of pupil diameter, reduce the influence of pupil effect on visual field detection.

 

2. Personalized design, accurate clinical analysis, accurate and rapid examination strategy.

 

3. Provide various calcium testing procedures and report analysis according to international Goldman Sachs standards.


 

 

Company Introduction

 

Hot Products

Digital Eye Fundus Camera retinal imaging camera fully automatic digital eye fundus camera RETICAM ...
Non Mydriatic Automatic Fundus Camera retinal fundus camera Small Pupil Imaging Red Free Non ...
High Resolution Optical Coherence Tomography Machine for Microscopic Imaging The Retiview 500 is an ...
Fully Display Three-Dimensional Structure Information Fundus Optical Coherence Tomography Machine ...
Compact Design No External Computer Is Needed Optical Coherence Tomography Machine Compared to other ...
automated visual field test machine Goldman international standard scientific and intelligent Visual ...