Home Companies YUSH Electronic Technology Co.,Ltd

Stainless Steel Digital Nitrogen Cabinet , Energy Saving Humidity Control Dry Cabinet

YUSH Electronic Technology Co.,Ltd

Contact Us

[China] country

Trade Verify

Address: Building H, GuoRui Pioneering Park, No. 1068 Jinyang East Road, Lujia Town, Kunshan, Suzhou,Jiangsu,China.

Contact name:Eva liu

Inquir Now

YUSH Electronic Technology Co.,Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Stainless Steel Digital Nitrogen Cabinet , Energy Saving Humidity Control Dry Cabinet

Country/Region china
City & Province suzhou jiangsu
InquireNow

Product Details

Stainless Steel Digital Nitrogen Cabinet , Energy Saving Humidity Control Dry Cabinet

 



Control the humidity: 20% -60% RH 10% -20% RH 1% -10% RH..

 

Product Specifications Model:

Product Name

Model

Humidity control range

Control mode

Antistatic humidity Electronic Cabinets

GRD160F

20%-60%RH

Can be set

Low humidity Antistatic Electronic Cabinets

GRD160BF

10%-20%RH

Automatic

Ultra-low wet Antistatic Electronic Cabinets

GRD160CF

1%-10%RH

Automatic

 

 

Technical parameters:
Dimensions (W * D * H): 450 * 450 * 1010mm
Internal Dimensions (W * D * H): 405 * 420 * 840mm
Capacity : 160L
Shelf : 3
Power : 110V/220V 50Hz/60Hz adaptive
Average power : 15-60W
Color: gray and black
Accuracy: Humidity : ± 3% RH, temperature : ± 1 ℃
Display : High brightness LED full-screen , independent of temperature and humidity display
Anti-static coefficient : 106-108
ESD casters
Ground wire : 1MΩ ( length : 800 mm)
Optional : lighting system inside : inside with LED lighting , and with a membrane keypad switch, easy to observe the items inside without opening the door state

 


Main technical characteristics

Humidity Sensor: American original brand honeywell error is less than ± 2% RH precision humidity sensor. Modular design , high precision and high stability.

Temperature and humidity control and display : precision LED digital temperature display full-screen display :. -9 ℃ ~ 99 ℃, accuracy ± 1 ℃. Humidity Display : 0% ~ 99% R. Accuracy ± 3% RH. Display accuracy and stability, long service life.

Humidity Built central controller modular design , avoid touching extremely dangerous , safe and reliable. Humidity setting with memory function, power failure without re- setting. Microcomputer automatic operation, without human care

Dehumidification Host : use technology cooperation with Japan , preclude the use of hygroscopic materials imported polymer and China's patent . The shell is made of imported high-temperature plastic particles repression. Durable without deformation.

Power system: UL CE certification preclude the use of the power of Switching power supply system

Cabinet structure : cabinet material : 1.0mm high quality steel enclosure with several automatic punch presses and CNC sheet metal equipment high production, manufacturing precision , good airtight enclosure . Bian cabinet surface coating with imported resins, automatic powder coating line . Good quality and appearance .

Bottom of the cabinet is installed 360 ˚ rotation with brake casters for easy mobility and fixed .

Door windows : window frames crimping 5.0mm high-strength tempered glass door handle using planar integrated handle the pressure of high-strength lock with anti-theft feature .

Load Laminates : Laminates used to strengthen the structure design , high strength material contained , uniform load up to 100kg load bearing force , the height gap can be adjusted according to the height to put items . Make it easier for storage . Space utilization higher.

Dehumidification principle: Electronic Cabinets dehumidification host using environmentally friendly absorbent polymer material , the use of shape memory alloy systems dehumidification method , a unique patented technology, with intelligent microcomputer program control system simply set the desired humidity control device automatically after work . . host shell is made of high-temperature flame-retardant materials , to prevent the occurrence of safety hazards. Automatic moisture off the design , you can still use chemical absorbent bit features to dampness, humidity rises within 24 hours does not exceed 10 %. No damp , no heat, no dripping . Energy saving, long life .
 


◆ How it works: dehumidification host the door open, the outer door closed , environmentally friendly polymer materials absorb moisture vapor within the Electronic Cabinets , the door is closed, the outer door opened, absorbent material heater , so the moisture evaporates into the Cabinets , the shape of the and internal memory alloy spring responsible for external doors open and close . above steps under program control system intelligent microcomputer control loop , gradually reduce the humidity in the Cabinets .


◆ Uses: mainly storing various forms of integrated circuit (IC)
As monolithic , LSI LSI, VLSI VLSI, Bipolar, MDS, CCD, MCM, DIP, SOP, SSOP, TSOP, VSOP, SDIP, SIP, SOJ, SVP, QFJ, CSP, KGD, PGA, QFP, TCP, LCA and BGA packaging.

 

 

Hot Products

White 1250L Humidity Control Camera Storage Cabinet For Cameras Lens Packaging & Delivery Packaging ...
LED Precision Desiccant Dry Box 624L For Electronic Components Storage Specifications 1.Desiccant ...
Precise LED Desiccant Dry Box , Humidity Dry Cabinet For Camera Equipment Storage Packaging & ...
1230L 1100W Desiccant Dry Box for SMT Protect Component , Highly Efficient Insulation GHA series ...
Stainless Steel Digital Nitrogen Cabinet , Energy Saving Humidity Control Dry Cabinet Control the ...
Electronic Components Storage Desiccant Dry Box 624L With 5 Shelves Specifications 1.Desiccant dry ...