Home Companies China World Technology Medical Equipment Service Group

Masima LNCS Patient Cable 1814 Ref Red LNC-10 For Masima SET® Rad-5® Pulse Oximeter

China World Technology Medical Equipment Service Group

Contact Us

[China] country

Trade Verify

Address: TianHe District,GuangZhou,GuangDong

Contact name:Kiara

Inquir Now

China World Technology Medical Equipment Service Group

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Masima LNCS Patient Cable 1814 Ref Red LNC-10 For Masima SET® Rad-5® Pulse Oximeter

Country/Region china
City & Province guangzhou guangdong
InquireNow

Product Details

 

Masima LNCS Patient Cable 1814 Ref Red LNC-10

 

 

►Brief Introduction

The LNCS Patient Cable Ref Red LNC-10 have the same indications for use as the applicable sensors.The LNC Patient Cable Ref Red LNC-10 are used with Masima LNCS® sensors. The LNC Patient Cable Ref Red LNC-10 and Masima LNCS Sensors have been validated with Masima SET® Rad-5® Pulse Oximeter.

 

 

Warning

Ensure the cable is Philipilipysically intact, with no broken or frayed wires or damaged parts. Visually inspect the cable and discard if cracks or discoloration are found.

Carefully route patient cable to reduce the possibility of patient entanglement or strangulation.

Do not attempt to reprocess, recondition or recycle Masima sensors or patient cables as these processes may damage the electrical components, potentially leading to patient harm.

Masima sensors and cables are designed for use with devices containing Masima SET® oximetry or licensed to use Masima sensors.

All sensors and cables are designed for use with specific monitors. Verify the compatibility of the monitor, cable and sensor before use, otherwise degraded performance and/or patient injury can result.

Failure to properly connect the sensor or the oximeter module to the cable will result in intermittent readings, inaccurate results, or no reading.

To avoid damage to the cable, always hold it by the connector rather than the cable when connecting or disconnecting either end.

Always refer to the oximeter module operators manual for complete instructions or additional instructions.

To prevent damage, do not soak or immerse the sensor or cable in any liquid solution. Do not attempt to sterilize the cable or sensor.

 

 

 

Instructions

1. Attach the LNC Patient Cable to the device

Orient the connector of the cable to mate with the connector on the patient cable connector of the Masima SET instrument and insert.

2. Attaching the LNC Cable to the LNCS Sensor.

  1. Insert the sensor connector completely into the patient cable connector (Fig. 1) .
  2. Completely close the protective cover (Fig. 2).

3. Disconnecting the LNC Cable from the LNCS Sensor

  1. Lift the protective cover to gain access to the sensor connector (Fig. 3).
  2. Pull firmly on the sensor connector to remove from the patient cable (Fig. 4).

 

 

Fitments

 

MindrayACCUTORR 5
ACCUTORR PLUS
DUO
PASSPORT 2
PASSPORT 2 LT
PASSPORT XG
SPECTRUM OR
TRIO
PASSPORT V
V12
V21
SPECTRUM
EXPERT
ACCUTORR V
Philipilipysio-ControlLIFEPAK 12
LIFEPAK 11
LIFEPAK 15
Welch AllynPROPAQ CS
SPOT VITAL SIGNS LXI
ZOLLM SERIES
E SERIES
GE MedicalPRO 300V2
MasimaRADICAL 7

 

 

 

If you have any questions about Masima LNCS Patient Cable 1814 Ref Red LNC-10, please feel free to contact us at any time, we are glad to answer them. Looking forward to receiving your early inquiry. Thanks for Your Cooperation.

 

Hot Products

004-0004-004 2016792-002 REV A GE Dash4000 patient monitor display assembly 10.4inch Display ...
2026653-019 GE Dash3000 Dash4000 Dash5000 Patient Monitor Battery Door Battery door features High ...
P/N 2019271-001 GE Dash3000 Dash4000 Dash5000 Patient Monitor Display Flex Flat Cable About company ...
P/N 801394-001 GE Dash3000 Dash4000 Dash5000 Patient Monitor Power Supply Board The monitor ...
P/N 2026653-037 GE Dash3000 Dash4000 Dash5000 Patient Monitor Handle The handle has a variety of ...
P/N 1076374(1058272) Philipilip V60 Ventilator Battery 14.4V 11.0Ah 163Wh LOT M91484-P1 Install an ...