Particulate Air HEPA Filter PN 161236 00 For HAMILTON-C1 C1 Mechanical Ventilator

Country/Region china
City & Province guangzhou guangdong
Categories Solar Chargers
InquireNow

Product Details

HAMILTON medical high efficiency particulate air (HEPA) filter PN 161236 00 for HAMILTON-C1 mechanical Ventilator

 

 

 

► Brief Introduction

This HEPA (High efficiency particulate air) filter is working for HAMILTON-C1 mechanical Ventilator, and PN 161236 00. This is for the fresh air intake and the cooling fan.

HAMILTON-C1 mechanical ventilator requiring only a minimum of space, it combines invasive and noninvasive modes as well as high flow oxygen therapy with maximum mobility. The integrated high-performance turbine enables the HAMILTON-C1 to be completely independent from compressed air. This makes it an ideal companion for all patient groups in the intensive care unit, emergency ward, recovery room or intermediate care as well as in long-term acute care facilities and during intrahospital transport.

  • Adult, pediatric, and neonatal ventilation
  • More than 4 hours of battery operating time
  • Independence from gas cylinders or compressors
  • Noninvasive ventilation and integrated high
  • flow oxygen therapy
  • Advanced ventilation modes, including ASV® - Adaptive Support Ventilation

 

 

► Maintaining the filters

Summarizes the steps to exchange the HEPA filters in the back of the ventilator.

 

1. Remove and replace air filter.

 

2. Remove and replace fan filter.

 

3.Remove back panel.

 

4. Remove and replace HEPA filter. Replace back cover when finished.

 

 

 

Preventive maintenance

This perform preventive maintenance on your ventilator

IntervalPart/accessoryProcedure
Every month (or more often if required)Fan filters (rear panel), air intake filters (white filters on outside of HEPA filter)Check for dust and lint. If needed,
replace.
Yearly or as necessaryAir intake HEPA filterReplace

 

 

 

Environmental requirements

 

TemperatureOperation:5°C to 40°C (41°F to 104°F)
Storage:-20°C to 60°C (-4°F to 140°F)
AtmosPhilipiliperic pressureOperation and storage:620 to 1100 hPa
Relative humidityOperation and storage:10% to 95%, noncondensing
Altitude-650 to 4000 m (-2,132 to 13,123 ft)
Note that at higher altitudes the ventilator performance may be limited. The Performance limited by high altitude alarm is generated and a message is shown on the display

 

 

 

► About Company

We have supply the Parts, Accessories and medical equipment of Patient Monitor, Defibrillator Machine, ECG Machine, Ventilator, Anesthesia Machine, Ultrasound such as
GE,
Philipilip,
Mindray,
Goldway,
Nihon Kohden,
Med-tronic,
Masi-mo,
Drager,
Edan,
Zoll,
etc.

 

 

 

Please kindly contact us, if you are interested in HAMILTON medical high efficiency particulate air (HEPA) filter PN 161236 00 for HAMILTON-C1 C1 mechanical Ventilator, Thank you!

 

Hot Products

Refurbished GE DASH2000 Patient Monitor Standard Parameter For Sale GE Dash2000 device is designed ...
Hospital Medical Equipment Mindray BeneHeart R12 ElectrocardiograPhilipilip ECG Machine ► Brief ...
004-0004-004 2016792-002 REV A GE Dash4000 patient monitor display assembly 10.4inch Display ...
2026653-019 GE Dash3000 Dash4000 Dash5000 Patient Monitor Battery Door Battery door features High ...
P/N 2019271-001 GE Dash3000 Dash4000 Dash5000 Patient Monitor Display Flex Flat Cable About company ...
P/N 801394-001 GE Dash3000 Dash4000 Dash5000 Patient Monitor Power Supply Board The monitor ...