Philip Heartstart XL+ Defibrillator Display Inverter Board Backlight Inverter High Voltage Board PS-DA0291-298 453564176811
► Brief Introduction
The power for the display backlight is provided by a Backlight Inverter PCA. The display also contains a backlight, which is powered by the Backlight Inverter PCA. The Backlight Inverter PCA converts DC current from the system power supply to high voltage alternating current. The Backlight Inverter PCA is mounted on the Front Chassis.
► Features
Provides power to the backlight of the defibrillator display for improved visibility in low-light situations.
Allows for high voltage conversion to power the display and other components of the defibrillator.
Enhances the overall functionality and performance of the defibrillator by ensuring proper power distribution.
Designed to be durable and reliable for long-lasting use in emergency situations.
Compatible with the Philip Heartstart XL+ model for easy integration and replacement.
► How to use
The Philip Heartstart XL+ Defibrillator Display Inverter Board Backlight Inverter High Voltage Board is an essential component of the defibrillator that is responsible for providing the necessary power to the display screen and the high voltage components of the device.
The backlight inverter is responsible for providing the necessary power to illuminate the display screen on the defibrillator, allowing the user to clearly see the information and prompts displayed on the screen.
The high voltage board is responsible for providing the necessary power to the high voltage components of the defibrillator, which are essential for delivering the life-saving electric shock to the patient in cardiac arrest.
These boards work together to ensure that the defibrillator functions properly and is able to deliver the necessary shock to the patient when needed. If any of these components fail, it can prevent the defibrillator from working properly and delivering the life-saving treatment to the patient. Regular maintenance and testing of these components is essential to ensure the proper functioning of the defibrillator.
► Specification
Symptom | Possible Cause | Suggested Solution |
Display is all dark, no response to controls. In Monitor Mode, press the Sync button. Does it light up? | Yes: Failure of backlight Display failure | • Replace Inverter PCA • Replace Display Assembly • Replace SOM PCA • Replace Processor PCA |
Display unusually dim. | • Backlight Inverter failure • Backlight bulb failure | • Replace Inverter PCA • Replace Display Assembly |