Home Companies China World Technology Medical Equipment Service Group

Philip Heartstart XL+ Defibrillator ECG Interface Panel Board Assembly

China World Technology Medical Equipment Service Group

Contact Us

[China] country

Trade Verify

Address: TianHe District,GuangZhou,GuangDong

Contact name:Kiara

Inquir Now

China World Technology Medical Equipment Service Group

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Philip Heartstart XL+ Defibrillator ECG Interface Panel Board Assembly

Country/Region china
City & Province guangzhou guangdong
Categories Other Health Care Products
InquireNow

Product Details

Philip Heartstart XL+ Defibrillator ECG Interface Panel Board Assembly

 

 

 

► Brief Introduction

The ECG signal picked up by the ECG monitoring electrodes is carried by the ECG cable to the ECG port, and then to the Processor PCA, where it is amplified, filtered, and digitized.

The Processor PCA then performs digital signal processing on the ECG data, and is responsible for:

• Formatting and presenting the ECG to the display and to the printer.

• Counting heart rate and generating heart rate alarms.

• Reporting on the status of the patient connection, and alerting the user to measurement problems.

• Arrhythmia analysis and alarms.

 

 

 

Arrhythmia Monitoring

The HeartStart XL+ uses the ST/AR Algorithm. Arrhythmia analysis provides information on your patient’s condition, including heart rate and arrhythmia alarms. The HeartStart XL+ uses the ECG lead appearing in Wave Sector 1 for single-lead arrhythmia analysis.

During arrhythmia analysis, the monitoring function continuously:

• Optimizes ECG signal quality to facilitate arrhythmia analysis. The ECG signal is continuously filtered to remove baseline wander, muscle artifact and signal irregularities. Also, if the patient’s paced status is set to yes, pace pulses are filtered out to avoid processing them as QRS beats.

• Measures signal features such as R-Wave height, width and timing.

• Creates beat templates and classifies beats to aid in rhythm analysis and alarm detection.

• Examines the ECG signal for ventricular arrhythmias and asystole.

 

 

 

► Specification

ItemConditionRange
Temperature RangeOperating0 to 45°C (32 to 113°F)
Storage20 to 70°C (-4 to 158°F)
Humidity RangeOperating90 % Relative Humidity (RH) max.
Storage90 % Relative Humidity (RH) max.
Altitude RangeOperating1014 mbar to 572 mbar (0 to 15,000ft; 0 to 4,500m)

 

 

 

Quality Instructions

Our company have one division of labour on the basis of specialization, highly cooperative group, rich technical force of medical machines development. Our expert team provides prompt, dependable solutions for sales and repairs on patient monitor, defibrillator machine, ECG/EKG machine and other accessories or repair parts. We have been always focusing on producing superior products and providing first-class customer service. What calls for special attention is that there are both brand new and second-hand products for sell. Please remember to carefully distinguish them when placing your orders. Otherwise, it will cause unnecessary troubles. If you have any doubts about the product quality, please don’t hesitate to contact us. We will reply to you as quickly as possible.

 

 

 

If you have other questions about Philip Heartstart XL+ Defibrillator ECG Interface Panel Board Assembly , please feel free to contact us. We are always ready to serve you.

 

Hot Products

Mindray MPM Module Top Frame ► Brief Introduction The Mindray MPM Module Top Frame is likely a ...
Mindray MPM Module Pump with Solenoid Valves Assembly ► Brief Introduction The monitor uses the ...
Mindray MPM Module Parameter board with IBP M51A-20-80852 M51A-30-80853 ► Brief Introduction Mindray ...
Mindray MPM Module Parameter board With IBP FCF-060701 6800-20-50325 6800-30-50324 ► Brief ...
Mindray MPM Module Parameter board M51A-20-80860 ► Brief Introduction The Mindray MPM Module ...
Mindray MPM Module Infrared board With IBP MPM module infrared communication back board FCF-060701 ...