Regarding the product in the picture, it is Philip Heartstart XL+Defibrillator Paddle Connector Assembly model 453564104981. As an integral part of the defibrillator handle assembly, it is indispensable.
Several precautions in daily work
Emergency cardioversion defibrillation
Display the heart rhythm in "Paddle" mode to avoid the use of
monitoring electrodes that may affect the timing of rescue or the
absence of graphic records after discharge;
Discharge during bradycardia or electrical arrest is considered a
harmful operation
When pre excitation syndrome or ventricular tachycardia is
synchronized, it is necessary to press the "Sync" button to avoid
ventricular fibrillation induced by ventricular vulnerable phase
discharge.
Selective rhythms
Adequate preparation for anticoagulation; It is important to sign
the conversation before resuming the law;
Adequate preparation of antiarrhythmic drugs is necessary to
increase success rate, reduce recurrence rate, and be cautious when
combined with serious diseases or bradycardia. If necessary,
temporary pacemaker implantation surgery should be performed before
cardioversion.
The main measures for daily maintenance
(1) Improving equipment to make up for deficiencies: During the use
of DR, we should pay attention to improving the equipment to
address the issue of the infrared remote control equipped with DR
not being able to perform close range exposure. We should analyze
the causes of different types of problems, and then carry out fault
handling according to specific situations. This can solve the
problem faster and reduce the degree of DR damage.
(2) Strictly follow the operating requirements: When using DR,
attention should be paid to the absence of any obstructions between
the DR infrared transmitter and receiver, and it is necessary to
ensure that analog and digital signals are transmitted using radio
waves within a range of 5 meters to ensure the accuracy of the
receiver and transmitter.
(3) Carefully identify possible faults: During normal use, it is
also important to identify possible faults such as system host
failure, inability to control panel, ineffective switch operation,
and DR system startup that is normal, but when the exposure key is
pressed for a long time, the system displays CPI error and cannot
start the system rotating anode during exposure in a timely manner.
Type: | Philip XL+ Defibrillator Paddle Connector Assembly |
Warranty period: | 90 Days |
Shipping Date: | 3-5 Working Days |
MODEL: | 453564104981 |
Storage temperature: | -20-70°c |
MOQ: | 1 PCS |
COLOR: | Several colors |
Delivery Date: | 3 - 5 Working Days |
Package | Standard export packaging |
The company has been professionally operating various brands of original medical monitoring instruments since 2015. The company has many professional senior engineers and has sufficient ability to undertake various medical equipment maintenance work. Covering motherboards, sensors, probes, modules, connectors, shells, etc. for various medical monitoring equipment.