Philip MX40 Patient Monitor Back Cover Casing DLP-001-09

Country/Region china
City & Province guangzhou guangdong
Categories Detox Foot Patch
InquireNow

Product Details

Philip MX40 Patient Monitor Back Cover DLP-001-09

 

 

 

 

Philip MX40 Patient Monitor Back Cover DLP-001-09 Brief Introduction 

 

 

The back cover of the Philip MX40 patient monitor protects the monitor's internal components and provides easy access for service and

 

maintenance. It is usually made of durable plastic and is designed to attach securely to the back of the monitor to ensure a snug fit. The back

 

cover may also have ventilation slots to allow good air circulation and prevent the monitor from overheating during operation. It is important that

 

the back cover remains securely attached to the monitor to ensure the safety and functionality of the device.

 

 

 

 

 

Back Cover Description 

 

 

Service personnel can find the following information on the label on the back of the MX40:

 

 

 

 

Service #: This is the Service Identification Number located on the back label and used to identify the device.

 

S/N: This is the Hardware Serial Number for the device located on the back label and used to identify the device.

 

SW SN: This is the Software License Number. It can be found on the Software License Certificate that shipped with the device.

 

Options: List of enabled product options on the device.

 

 

 

Enabled Product Option #

 

Product Option

 

S01

 

ECG only

 

S02

 

ECG and SpO2

 

S03

 

ECG and SpO2 Ready (for future upgrade)

 

C01

 

Enhanced Arrhythmia

 

C03

 

24 hours of Vitals Trends

 

J46

 

Short-Range Radio

 

M02

 

Impedance Respiration

 

 

 

 

 

About Philip MX40 Patient Monitor 

 

 

The MX40 is available in three models (ECG only, ECG and FAST SpO2, or ECG and SpO2 Ready (for future upgrade)..It is supported for use

 

with IntelliVue Information Center version N and IntelliVue Information Center iX version A. Limited support is available when used with IntelliVue

 

Information Center version L or M. For more information, see the "Operation" chapter with version L. or M.” The MX40 is compatible with

 

IntelliVue version G or later patient monitors when connected wirelessly.

 

The MX40 is compatible with IntelliVue Cableless Measurements version A.1. The MX40 is compatible with the 862147 Access Point Controller,

 

version B.00.19 and the 865346 Access Point Controller, version C.00.04. The MX40 patient cable is compatible with IntelliVue MP2/X2,

 

MP5/MP5T/MP5SC, MP20/30 with MMS or X2, MP40/50 with MMS or X2, MP60/70 with MMS or X2, MP80/90 patient monitor platforms. with

 

MMS or X2 and MX800/700/600 with MMS or X2.

 

 

 

 

If you're interested in Philip MX40 Patient Monitor Back Cover DLP-001-09,feel free to contact us .Thank you .

Hot Products

Mindray MPM Module Top Frame ► Brief Introduction The Mindray MPM Module Top Frame is likely a ...
Mindray MPM Module Pump with Solenoid Valves Assembly ► Brief Introduction The monitor uses the ...
Mindray MPM Module Parameter board with IBP M51A-20-80852 M51A-30-80853 ► Brief Introduction Mindray ...
Mindray MPM Module Parameter board With IBP FCF-060701 6800-20-50325 6800-30-50324 ► Brief ...
Mindray MPM Module Parameter board M51A-20-80860 ► Brief Introduction The Mindray MPM Module ...
Mindray MPM Module Infrared board With IBP MPM module infrared communication back board FCF-060701 ...