China World Technology Medical Equipment Service Group |
Verified Suppliers
|
|
Change the product to Philip Heartstart XL+Defibrillator machine
Signal Light Cable
The signal light cable of the defibrillator provides the connection
between the defibrillator function and the signal light. When the
patient is in the process of rescue, the cable connection will make
the signal light display green. If the defibrillator malfunctions,
the signal light will display red or not.
Every time you start using the defibrillator:
1. Check if all cables of the defibrillator are connected correctly
and if there is any damage or aging.
2. Check if the required accessories for the defibrillator
(conductive paste, lead wire, ECG electrode, printing paper, etc.)
are complete. Discovering that the printing paper is about to run
out, promptly insert new thermal printing paper and confirm that
the thermal direction is installed correctly.
3. Check if the defibrillation electrode plate and defibrillation
handle are intact.
4. After use, it is necessary to check whether the power of the
device is sufficient. If it is insufficient, it is necessary to
charge it in a timely manner to ensure that the device is in good
condition and standby.
Problems with defibrillation equipment in emergencies are generally
due to insufficient testing, insufficient power, or low battery
power.
power, and no shift inspections.
Comprehensive testing and automatic verification of correct cable
electrode connections, checking electrode type and
Check key circuits for discharge testing
There is no need to disconnect the electrodes or handles, or use
other equipment to check shock delivery. this system
Will automatically detect unconnected or dry electrodes and print
device monitoring results or send
Via electronic journal.
·The system status indicator light will monitor the readiness of
the defibrillator at any time. If something goes wrong, then
The display will show the cause of the problem.
·If the device automatically detects an error, a report or email
will be automatically generated to alert relevant personnel
personnel*
·During a shift, users can also record other situations in the
emergency room through defibrillation
Monitor and improve the overall quality of emergency care.
Type: | Philip XL+ Defibrillator Signal Light Cable |
Warranty period: | 90 Days |
Shipping Date: | 3-5 Working Days |
MODEL: | Signal Light Cable |
Storage temperature: | -20-70°c |
MOQ: | 1 PCS |
COLOR: | Black |
Delivery Date: | 3 - 5 Working Days |
Package | Standard export packaging |
The company has been professionally operating various brands of original medical monitoring instruments since 2015. The company has many professional senior engineers and has sufficient ability to undertake various medical equipment maintenance work. Covering motherboards, sensors, probes, modules, connectors, shells, etc. for various medical monitoring equipment.
We default to express delivery by DHL,Fedex,etc.We will contact you as soon as possible when sending express delivery. If you have any questions after receiving the express delivery, please feel free to contact us at any time.