Datex 5-Lead 10-Pin ECG Cable DLG-011-05

GE Datex 5-Lead 10Pins ECG Cable REF: DLG-011-05 Reusable New Compatible Medical Accessories For Sale

 

Brief Description

Datex 5-Lead 10-Pin ECG Cable DLG-011-05 - Can monitor ECG for patients, mainly provides connection to the patient for measurement. However, do not attach it directly to the patient. Instead, connect it through electrode pads or gel as a medium. It is a 5-lead cable and is compatible with GE equipment. This cable can be reused, but please check it before each use. If there is any rupture or abnormality, please stop using it immediately. Please clean it regularly to keep the cable clean.

 

 

► Specification

Product CategoryECG
Product TypeCable
Number of Leads5
Number of Pins10-Pin
ShieldedYes
Color CodingAAMI/IEC
Single-Patient Use OR Multi-Patient UseMulti-Patient Use
REFDLG-011-05
ConditionNew Compatible
Packaging Unit1 Pack = 1 Cable
Sterile OR Non-SterileNon-Sterile
Minimum Shelf LifeNone
Warranty90 Days
Delivery Date3 - 5 Working Days

 

 

More Details

Contact between electrodes and patient

Poor electrode-to-patient contact can result in poor signal quality and associated waveforms, as well as false alarm conditions. Poor contact may be caused by poor skin preparation, dry electrode gel, and/or defective ECG cables or lead wires. Therefore, it is necessary to ensure good contact between the electrode and the patient to achieve more accurate results. The specific matters are as follows:

1. After connection, the electrodes should not move in any way;

2. Periodically check whether the electrode is firmly adhered to the patient and in complete contact. If the electrode moves easily, it indicates that the electrode connection is too loose and may need to be replaced;

3. Tape the wire approximately 3-4 inches from the electrode, leaving slack in the wire to prevent it from pulling on the electrode.

 

Lead Selection

It is important to select the appropriate leads for the patient, showing the largest amplitude and cleanest signal so that the monitor can accurately detect the QRS complexes and R waves. Please follow the following when making your selection:

1. The QRS complex should be high and narrow (recommended amplitude > 0.5 mV);

2. The R wave should be above or below baseline (but not biphasic);

3. P wave should be less than (1/5) R wave height;

4. T wave should be less than (1/3) R wave height.

 

 

Detailed Photos

 

 

 

 

 

 

 

Thanks for your interest in GE Datex 5-Lead 10Pins ECG Cable REF: DLG-011-05 Reusable New Compatible Medical Accessories, please feel free to contact me. Thank you for your time and wish you have a happy life.

Hot Products

Mindray Pulse Oximeter PM-60 Brief Introduction of Mindray Pulse Oximeter PM-60 The PM-60 is a ...
Sino-K Medical SPH100 Handheld Spo2 Finger Tip Pulse Oximeter product features: The working ...
Olympus EVIS LUCERA CV-260 Endoscopy Endoscopy Function 1. Suction connector Connect the endoscope ...
Biolight BLT AnyView A5 Patient Monitor Modular Buckle ► About Biolight BLT AnyView A5 Patient ...
Mindray BIS LOC 2 Channel Cable Assembly 6800-30-50761 185-1014-MR 0010-21-42759 ► Brief Introductio...
Mindray BeneHeart D6 Defibrillator Machine ► Brief Introduction The Mindray BeneHeart D6 Defibrillat...