► Brief Introduction

The Hamilton Medical flow sensor is a device to measure patient air flow with Hamilton Medical ventilators. The autoclavable flow sensor is not to be used in an environment with magnetic resonance imaging (MRI) equipment. Connect the small tubes of the flow sensor to the corresponding color-coded connectors on the ventilator panel.Insert the flow sensor between the Y-piece of the patient circuit and the patient connection. The end of the flow sensor that should face the patient is marked by “Patient” and an arrow indicating flow direction. It is recommended that you use a short section of flexible tubing between the flow sensor and the actual patient connection.The flow sensor tubes must be attached to the breathing circuit tubes to avoid entangling or hooking the flow sensor tubes in other equipment.

 

 

 

Quality Instructions

Our company have one division of labour on the basis of specialization, highly cooperative group, rich technical force of medical machines development. Our expert team provides prompt, dependable solutions for sales and repairs on patient monitor, defibrillator machine, ECG/EKG machine and other accessories or repair parts. We have been always focusing on producing superior products and providing first-class customer service. What calls for special attention is that there are both brand new and second-hand products for sell. Please remember to carefully distinguish them when placing your orders. Otherwise, it will cause unnecessary troubles. If you have any doubts about the product quality, please don’t hesitate to contact us. We will reply to you as quickly as possible.

 

 

 

► Packing Instructions

In order to ensure that the goods are delivered to customers in good condition, we will carefully and patiently pack the products. Please rest assured that we will use high-quality packaging materials to pack the goods to avoid being scratched or impacted during transportation. Generally speaking, there is no problem with the goods you receive. But if you find any problems with the goods during transportation, please contact us as soon as possible. But please pay special attention, if the problem is not caused by transportation, it is another matter. In short, after careful inspection by our engineers and our careful packaging, the goods will eventually arrive in your hands intact.

 

 

 

► Procedure for attaching the flow sensor tube to the breathing tube

1 Use pipe ties to tie the flow sensor tubing to the breathing circuit tubing. Choose the appropriate length as needed to ensure it does not block breathing airflow.

2 Insert the tip of the pipe tie (the end with the ball) into the opening on the other end.

 

 

 

 

► Clean

When large impurities or objects appear in the main body or pipeline of the flow sensor, be sure to clean it before Place components in an ultrasonic water bath for cleaning.

1 Place the flow sensor into the ultrasonic water bath and soak it for five minutes.The water temperature in the ultrasonic water bath should not be higher than 40°C (104°F).You can optionally add detergent (Neodisher Mediclean forte 0.5 - 2%).

2. Remove visible impurities on the flow sensor body and pipelines by flushing or wiping them.You can add detergent (Neodisher Mediclean forte 0.5 - 2%) to the rinse water.Never use hard tools or stiff-bristled brushes to remove stubborn impurities.

3 Please rinse the flow sensor carefully in 30 ml of freshly made distilled or deionized water (including two root canal) at least five times (or according to a proven cleaning schedule).

 

 

 

Specification

Operating:-20°C to 50°C (-4°F to 122°F)
Relative humidity:5 - 95%, noncondensing
Storage:-20°C to 70°C (-4°F to 158°F)

 

 

 

 

Thank you for your time! If you want to explore more details about Hamilton REF 950815 Reusable Flow Sensor 1.88m 15m X 15f 22m connectors , please let us know. Any inquiry will be highly appreciated and thanks for your support.

 

Hot Products

Mindray Pulse Oximeter PM-60 Brief Introduction of Mindray Pulse Oximeter PM-60 The PM-60 is a ...
Sino-K Medical SPH100 Handheld Spo2 Finger Tip Pulse Oximeter product features: The working ...
Olympus EVIS LUCERA CV-260 Endoscopy Endoscopy Function 1. Suction connector Connect the endoscope ...
Biolight BLT AnyView A5 Patient Monitor Modular Buckle ► About Biolight BLT AnyView A5 Patient ...
Mindray BIS LOC 2 Channel Cable Assembly 6800-30-50761 185-1014-MR 0010-21-42759 ► Brief Introductio...
Mindray BeneHeart D6 Defibrillator Machine ► Brief Introduction The Mindray BeneHeart D6 Defibrillat...