Quick Detail:

 

There are several steps when selecting the ECG lead cable to connect to a defibrillator:
1. Turn on the power and check the synchronization performance, select the higher lead for R-wave inspection.
2. After anesthesia is performed as required, the electrode pads must be placed as required.
3. You must choose the amount of charging energy to ensure safe use of electricity.
4. Unrelated personnel should not come into contact with the patient, hospital bed or equipment connected to the patient.
5. ECG, blood pressure, respiration and consciousness should be monitored after electric shock.

 

 

Key features:

 

Product CategoryDefibrilator ECG Lead Cable
Use  EquipmentZoll M Series E Series R Series Defibrilator
Package Weight0.2 kg
Packaging Unitmore lead set
CE CertifiedYes
Size1.5m*6cm
Patient ApplicationChild; Adult

 

 

FAQ:

 

Do the ECG monitoring leads need to be removed during defibrillation?
Answer: This requires checking whether the ECG monitoring leads equipped with the bedside ECG monitor are defibrillation-proof ECG lead wires. If it is a defibrillation-proof ECG lead wire, it does not need to be removed during defibrillation. Otherwise, the bedside ECG monitoring wire needs to be removed.

 

When defibrillating, should I choose lead II or lead Paddles? Is there a difference between the two?
Answer: When using a defibrillator for ECG monitoring, lead II should be selected; if a defibrillator is not used to monitor the patient's heart rhythm, when the patient suddenly changes and it is judged that defibrillation is needed, the lead should be immediately adjusted to Paddles lead. , which makes it easier to check whether the patient has ventricular fibrillation or pulseless ventricular tachycardia before charging for defibrillation. Because after choosing Paddles leads, you only need to place the two electrode pads on the chest to check the patient's heart rhythm, which is much faster than checking the heart rate by connecting cable leads and pasting electrode pads.

 

How to monitor whether the monitoring function of the defibrillator is intact?
Answer: Select the lead as Paddles lead, and touch the sternum and apex electrode pads with both hands respectively. If the ECG waveform is displayed on the screen, it means that the monitoring function of the defibrillator is good.

 

Is it necessary to check the defibrillator every day and check the system time on the instrument?
Answer: Yes, the power plug should be unplugged every day and the defibrillator should be tested to ensure smooth use during rescue. You also need to pay attention to the system time and calibrate it according to the time. Because after each defibrillation operation, the instrument will automatically print a record based on the system time. If the system time is wrong, you will face embarrassment when providing evidence in medical disputes. Currently, there are quality standards that stipulate that the time difference between the defibrillator and Beidi cannot be greater than 2 minutes.

 

 

 

About delivery:

 

 

We default to express delivery by DHL. We will contact you as soon as possible when sending express delivery. If you have any questions after receiving the express delivery, please feel free to contact us at any time.

 

 

 

 

 

 

 

 

 


 

Hot Products

Mindray Pulse Oximeter PM-60 Brief Introduction of Mindray Pulse Oximeter PM-60 The PM-60 is a ...
Sino-K Medical SPH100 Handheld Spo2 Finger Tip Pulse Oximeter product features: The working ...
Olympus EVIS LUCERA CV-260 Endoscopy Endoscopy Function 1. Suction connector Connect the endoscope ...
Biolight BLT AnyView A5 Patient Monitor Modular Buckle ► About Biolight BLT AnyView A5 Patient ...
Mindray BIS LOC 2 Channel Cable Assembly 6800-30-50761 185-1014-MR 0010-21-42759 ► Brief Introductio...
Mindray BeneHeart D6 Defibrillator Machine ► Brief Introduction The Mindray BeneHeart D6 Defibrillat...