Home Companies China World Technology Medical Equipment Service Group

Philip M1019A Anesthetic Gas Monitor Watertrap M1657B 989803110871 M1658A

China World Technology Medical Equipment Service Group

Contact Us

[China] country

Trade Verify

Address: TianHe District,GuangZhou,GuangDong

Contact name:Kiara

Inquir Now

China World Technology Medical Equipment Service Group

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Philip M1019A Anesthetic Gas Monitor Watertrap M1657B 989803110871 M1658A

Country/Region china
City & Province guangzhou guangdong
InquireNow

Product Details

 

Philip M1019A Anesthetic Gas monitor Watertrap M1657B 989803110871 (use with M1658A)

 

 

► Brief Introduction

The Philip M1019A Anesthetic Gas Monitor is a medical device used to monitor the concentration of anesthetic gases in a patient's breathing circuit during surgery or other procedures where anesthesia is administered. The water trap M1657B (part number 989803110871) is an accessory used with this monitor.A water trap is a component designed to prevent moisture or condensation from entering the gas monitor's sensing system. In anesthesia monitoring, it's crucial to maintain the accuracy and reliability of gas concentration measurements, and the water trap helps in ensuring that any moisture present in the breathing circuit does not interfere with the proper functioning of the monitor. The watertrap prevents water and other fluids from passing into the gas analyzer and causing contamination and/or internal occlusions. It has a water reservoir in which fluids are collected, two water separation filters, and two shut-off fuses as a backup mechanism for the water separation filters.The watertrap is for multi-patient use. It must be exchanged at least every two weeks or when watertrap is full.

 

 

 

► Connecting Gas Analyzer Accessories

The gas analyzer accessories and part numbers are listed in the accessories section.

1. Insert the M1657B watertrap into the watertrap socket by gently pushing it up and in. Make sure that the watertrap snap lock clicks into place.

2. Connect the gas sample tubing to the Luer connector of the watertrap.

3. Connect the other end of the gas sample tubing to the patient via the airway adapter.

 

 

 

► Functional

  • The Philip M1657B water trap, designed for use with the M1019A Anesthetic Gas Monitor, serves a specific function within the anesthesia monitoring system. While water traps typically serve a straightforward purpose of preventing moisture or condensation from entering sensitive gas monitoring equipment, specific features may vary depending on the manufacturer and model. Unfortunately, detailed features specific to the M1657B water trap are not readily available in public documentation.
  • However, here are some common features you might expect from a water trap used in anesthetic gas monitoring:
  • Moisture Prevention: The primary function of the water trap is to prevent moisture or condensation from entering the gas monitor's sensing system. This helps maintain the accuracy and reliability of gas concentration measurements.
  • Compatibility: The water trap is designed to be compatible with the Philip M1019A Anesthetic Gas Monitor, ensuring proper fit and functionality.
  • Ease of Installation: The water trap should be easy to attach securely to the gas monitor's gas inlet port, with a design that facilitates quick and hassle-free installation.
  • Transparent Construction: A transparent housing or design feature allows healthcare providers to visually inspect the water trap for any accumulation of moisture or debris without the need for disassembly.
  • Durable Construction: The water trap should be constructed from durable materials capable of withstanding the rigors of clinical use and repeated sterilization or cleaning procedures.
  • Minimal Dead Space: A design that minimizes dead space within the water trap helps ensure that gases flow smoothly through the anesthesia delivery system, maintaining accuracy in gas concentration measurements.
  • Easy Maintenance: The water trap should be designed for easy maintenance, with components that can be quickly cleaned or replaced as needed to ensure optimal performance.
  • It's essential to consult the product documentation provided by Philip Healthcare or contact their customer support for detailed information on the features and specifications of the M1657B water trap specific to the M1019A Anesthetic Gas Monitor.

 

 

Specification

 

AgentRange (vol%)AccuracyResolutionRise Time
Halothane0 - 8.50.15 vol% + 15.0% relative0.05< 500
Enflurane0 - 10.00.15 vol% + 15.0% relative0.05< 500
Isoflurane0 - 8.00.15 vol% + 15.0% relative0.05< 500
Sevoflurane0 - 10.00.15 vol% + 15.0% relative0.05< 500
Desflurane0 - 20.00.15 vol% + 15.0% relative0.05< 500

 

 

 

Thank you for your time! If you are interested in Philip M1019A Anesthetic Gas monitor Watertrap M1657B 989803110871 (use with M1658A), welcome to place your orders. If you have other questions about our products or services, please feel free to contact us. We are always ready to serve you.

Hot Products

Goldway UT4000F PRO Patient Monitor Philip Goldway UT4000F PRO Patient Monitor By GOLDWAY INDUSTRIAL ...
Goldway UT4000F PRO Multi-parameter patient monitor Goldway UT4000F PRO Multi-parameter patient ...
Mindray Pulse Oximeter PM-60 Brief Introduction of Mindray Pulse Oximeter PM-60 The PM-60 is a ...
Sino-K Medical SPH100 Handheld Spo2 Finger Tip Pulse Oximeter product features: The working ...
Olympus EVIS LUCERA CV-260 Endoscopy Endoscopy Function 1. Suction connector Connect the endoscope ...
Biolight BLT AnyView A5 Patient Monitor Modular Buckle ► About Biolight BLT AnyView A5 Patient ...