Home Companies China World Technology Medical Equipment Service Group

M3713A philip Adult Child Plus Multifunction Electrode Pads For M3860A M3861A M3535A XL+ XL MRx FR2 FR2+FR3 DFM100

China World Technology Medical Equipment Service Group

Contact Us

[China] country

Trade Verify

Address: TianHe District,GuangZhou,GuangDong

Contact name:Kiara

Inquir Now

China World Technology Medical Equipment Service Group

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

M3713A philip Adult Child Plus Multifunction Electrode Pads For M3860A M3861A M3535A XL+ XL MRx FR2 FR2+FR3 DFM100

Country/Region china
City & Province guangzhou guangdong
Categories Other Dental Hygiene
InquireNow

Product Details

M3713A philip Adult Child Plus Multifunction Electrode Pads For M3860A M3861A M4735A M3535A XL+ XL MRx FR2 FR2+FR3 DFM100

 

 

Connecting Multifunction Electrode Pads

To connect multifunction electrode pads:

 

 

1. Check the expiry date on the pad packaging and inspect the packaging for any damage. Discard expired or damaged mats.

 

2. Connect the therapy cable to the HeartStart XL+

 

3. Unpack and connect the pads connector to the end of the therapy cable

 

 

 

4. Apply the pads to the patient as directed on the pads packaging or according to your organization’s protocol.

 

 

 

Warning

For adults in AED mode, the multifunction pads must be in the forward tip position shown on the packaging. For infant/pediatric patients, the pad can be in an anteroposterior position.

 

 

 

Do not let the multi-function electrode pads touch each other or other ECG monitoring electrodes, lead wires, dressings, etc. Contact with metal objects may arc and burn patient skin during defibrillation and may divert current away from the heart

 

 

 

During defibrillation, air pockets between the skin and the multifunction pads may cause patient skin burns. To help prevent air pockets, make sure the pads are fully adhered to the skin. Do not use dry pads. Do not open the packaging of electrode pads before use.

 

 

Using Multifunction Electrode Pads

 

 

To set up defibrillation with multifunction pads:

 

  • Check the expiry date on the packaging of the electrodes and check whether the packaging is damaged.

 

  • If not pre-connected, connect the therapy cable to the HeartStart XL+

 

  • If the electrode pads are not expired and the package is not damaged, please open the package and connect the electrode pad connector to the end of the therapy cable

 

  • Apply the pads to the patient following the directions on the pad packaging or according to your institution's protocol

 

  •  Follow the defibrillation procedure

 

 

 

Event Information

 

 

Pads OnLogged when pads are applied to the patient.
Pads OffLogged after a PadPADS ONs On event if the multifunction electrode pads are removed from the patient or the Therapy cable is disconnected.
Pads ShortedLogged when a pad impedance is low.
Pads MarginalLogged when pad impedance is minimal.

 

 

Product Name

philip Adult Child plus multifunction electrode pads M3713A for M3860A M3861A M4735A M3535A XL+ XL MRx FR2 FR2+FR3 DFM100

 

Brandphilip
Part NoM3713A
Compatible with

M3860A M3861A M4735A M3535A XL+ XL MRx FR2 FR2+FR3 DFM100

 

 

 

 

Thank you so much for your attention .If you're interested in M3713A philip Adult Child Plus Multifunction Electrode Pads For M3860A M3861A M3535A XL+ XL MRx FR2 FR2+FR3 DFM100 ,feel free to contact us .Thank you .

 

 

Hot Products

philip VM6 LVDS cable 10 philip VM6 LVDS cable Medical Equipment For Hospital Product Description: ...
GE Dash 4000 Patient Monitor GE Healthcare DASH 4000 Patient Monitor Medical Equipment Good Working ...
philip CAPNOSTAT M2501A Patient Monitor CO2 Sensor philip CAPNOSTAT M2501A Patient Monitor CO2 ...
COMEN C60 Neonatal Patient Monitor Used for Hospital About COMEN C60 patient monitor COMEN C60 has ...
Used Mindary VS-600 VS600 Vital Signs Patient Monitor for Adult Pediatric Neonatal ❖ Mindray VS-600 ...
Medical Fetal Monitor Parts philip FM20 Fetal Monitor Cover Protector M2703-44150 philip FM20 Fetal ...