Edan F2 F3 F6 F9 Fetal Monitor Toco Transducer Probe IPX1 TP01-RQ-21 Compatible

Country/Region china
City & Province guangzhou guangdong
InquireNow

Product Details

EDAN F2 F3 F6 F9 TOCO Transducer Blue label MS3-31527(B) TPU REF 02.01.210259 MPN02.01.210259012 (6)06944413805507 (21)H18900830290

 

 


Brief Introduction

1) Placing Transducer Belt

Place the transducer belts across the bed, ensuring that the belt will be around the abdomen when it is fastened. Lay the patient on the bed.

Alternatively, the patient can take a sitting position. Arrange the belt around her abdomen.

 

2) Fixing the Transducer

Wipe any gel remaining on abdomen around this area. Place the TOCO transducer on the patient’s abdomen, which is flat and approximately 3 cm away from the fundus, e.g. slightly above the umbilicus on the left or on the right. The position should be different for different purposes: place the transducer close to the fetal buttocks for NST, and place it on fetal back in delivery.

Wrap the abdomen with the belt over the transducer. Fix the transducer by pushing its buckle through the overlapping section of the belt. Make sure the belt fits the patient snugly and comfortably.

 

3) Adjusting the Numeric to Zero

Press the AUTO ZERO key to adjust the numeric to the baseline. Make sure this is not done during a contraction.

Wipe off any gel presents on abdomen around this area

 

 

 

► Specifications

Baseline Drift due to Temperature Changes:≤ 1 unit/min/°C (free air)
≤ 5 units/min/°C (underwater)
Resolution:1
Zero Mode:Automatic/ Manual

 

 

Relocation of the Transducers

Transducers may be belted on the patient for a long time without stop. In rare cases, this may lead to irritations to the patient skin. To avoid skin irritations, please inspect the application site at least every three hours. If the skin quality changes, you should move the transducer to another site.Please periodically inspect the application site (between contractions) of TOCO transducer at least every three hours.

To reduce the risk of skin irritations, do not allow residual cleaning agent or disinfecting agent on the surface of transducers. Before using cleaning agent and/or disinfecting agent, refer to the cleaning and disinfecting sections in this user manual. Wipe the transducer surface with a cloth dampened with water before applying to the patient.

 

 

 

► Quality Guarantee

"Quality assurance" is our eternal pursuit and promise. We have a professional division of labor, a highly cooperative team, and a strong technical force in medical device development. Our expert team provides fast and reliable solutions for the sales and maintenance of patient monitors, defibrillators, ECG/ECG machines and other accessories or repair parts. We have always focused on producing quality products and providing first-class customer service. It is important to note that there are brand new and second-hand products for sale. Please distinguish them carefully when placing an order. Otherwise it will cause unnecessary trouble. If you have any questions about product quality, please contact us. We will get back to you as soon as possible.

 

 

 

Thank you for your time! If you have other questions about our Edan F2 F3 F6 F9 Fetal Monitor Toco Transducer Probe IPX1 TP01-RQ-21 Compatible , please feel free to contact us. We are always ready to serve you.

 

 

Hot Products

philip VM6 LVDS cable 10 philip VM6 LVDS cable Medical Equipment For Hospital Product Description: ...
GE Dash 4000 Patient Monitor GE Healthcare DASH 4000 Patient Monitor Medical Equipment Good Working ...
philip CAPNOSTAT M2501A Patient Monitor CO2 Sensor philip CAPNOSTAT M2501A Patient Monitor CO2 ...
COMEN C60 Neonatal Patient Monitor Used for Hospital About COMEN C60 patient monitor COMEN C60 has ...
Used Mindary VS-600 VS600 Vital Signs Patient Monitor for Adult Pediatric Neonatal ❖ Mindray VS-600 ...
Medical Fetal Monitor Parts philip FM20 Fetal Monitor Cover Protector M2703-44150 philip FM20 Fetal ...