Home Companies China World Technology Medical Equipment Service Group

Mindray Imec10 Patient Monitor Parts ECG + Sp02 + NIBP + Temp Parameter Board

China World Technology Medical Equipment Service Group

Contact Us

[China] country

Trade Verify

Address: TianHe District,GuangZhou,GuangDong

Contact name:Kiara

Inquir Now

China World Technology Medical Equipment Service Group

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Mindray Imec10 Patient Monitor Parts ECG + Sp02 + NIBP + Temp Parameter Board

Country/Region china
City & Province guangzhou guangdong
InquireNow

Product Details

Mindray Imec10 Patient Monitor ECG+Sp02+NIBP+Temp Parameter Board

 

 

Multi-parameter Module

 

The multi-parameter module, NIBP pump and electromagnetic valve are placed in the multi-parameter module bracket and secured to the back box with 4 screws.

The multi-parameter module is connected to the breakout board via a 2×7 pin cable, supplies power to the parameter module, communicates with the main board, and realizes analog output and synchronous defibrillation output. It uses the DSP processor as its core. For ECG applications, the ECG_ASIC chip developed by Mindray is used to perform 3/5/12-lead ECG and RESP (Lead I/II optional) measurements, greatly simplifying signal sampling and ECG verification with DSP.

For NIBP, IBP, TEMP measurements, a high-precision ADC is used to directly sample the corresponding parameter signals. Mindray SpO2 measurement is performed by stacking the caps. Nellcor and Masi-mo SpO2 boards are also compatible with multi-parameter modules, connected via BTB connectors

 

Removing the Parameter Module Assembly

 

1. Place the device on the workbench as shown in the figure below, and unscrew the four M4X10 screws:

2. Separately disconnect the multi-parameter signal line, blood pressure tube, ECG signal line, the cable between the parameter board and the interface board, the CO2 communication cable (optional) and the cable between the interface board and the M03B module (optional), As shown below

3. For standard equipment, the parameter module assembly can be removed directly.

4. For equipment with non-standard configuration, take out the parameter connector assembly and parameter module assembly from the rear shell, and separate the two assemblies according to the actual configuration:

For those configured with C.O. function: disconnect the C.O. signal cable, and then separate the parameter connector assembly and parameter module assembly, as shown below;

 

For those who have configured the C.O. function: disconnect the C.O. signal line, and then separate the parameter connector assembly and the parameter module assembly, as shown in the figure

 

 

To configure the mainstream CO2 function: disconnect the mainstream CO2 signal line, and then separate the parameter connector component and the parameter module component, as shown in the figure below

 

 

To configure the mainstream CO2 function: disconnect the mainstream CO2 signal line, and then separate the parameter connector component and the parameter module component, as shown in the figure below

 

To configure the micro-flow CO2 function: disconnect the CO2 pipeline, take the micro-flow CO2 joint assembly out of the parameter joint assembly, and then separate the parameter joint assembly from the parameter module assembly, as shown in the figure

 

 

 

 

 

 

 

Configure the Mindray M02C CO2 module: disconnect the cables between the CO2 tube, tube 1 and tube 2, the interface board and the M02C module, and then separate the parameter connector component from the parameter module component, as shown in the figure below

 

Notes

1. All pipes should be properly assembled and not snapped when reassembled.

2. For the equipment configured with optional C.O. or CO2 module, be sure to remove the parameter connector assembly and the parameter module assembly from the rear shell together, and then separate the two modules

3. Standard configuration, remove the parameter module separately

 

 

Specification

Product NameMindray Imec10 patient monitor ECG+Sp02+NIBP+Temp parameter board
BrandMindray
Use ForImec10 patient monitor
MOQOne piece
Warranty90 days

 

 

If you're inerested in Mindray Imec10 Patient Monitor ECG+Sp02+NIBP+Temp Parameter Board ,feel free to contact us .Thank you .

 

Hot Products

philip VM6 LVDS cable 10 philip VM6 LVDS cable Medical Equipment For Hospital Product Description: ...
GE Dash 4000 Patient Monitor GE Healthcare DASH 4000 Patient Monitor Medical Equipment Good Working ...
philip CAPNOSTAT M2501A Patient Monitor CO2 Sensor philip CAPNOSTAT M2501A Patient Monitor CO2 ...
COMEN C60 Neonatal Patient Monitor Used for Hospital About COMEN C60 patient monitor COMEN C60 has ...
Used Mindary VS-600 VS600 Vital Signs Patient Monitor for Adult Pediatric Neonatal ❖ Mindray VS-600 ...
Medical Fetal Monitor Parts philip FM20 Fetal Monitor Cover Protector M2703-44150 philip FM20 Fetal ...