Fukuda Model FX-7202 Special Medical Record Paper
Standard:110x140-150P New Ex-stock Fast Worldwide Shipping
Guangzhou YIGU Medical Equipment Service Co.,Ltd is a third party
medical equipment maintenance service provider. We are able to provide all kinds of medical equipment parts,
hospital devices, patient facility accessories and complete
machines.We are able to offer maintenance service by professional medical
equipment engineer with over 10 years specialized skills. We have been solved more than 90% of MP series medical
patient monitor module malfunctions (including software and
hardware), and repair M3001A modules more than 400 pcs every year. We deal with all medical patient monitors’ main brands
including: GE, , SPACELABS, SIEMENS, NIHON KOHDEN, MINDRAY,
Endoscopy, TYCO, NONIN etc. Our principle: integrity and pragmatic, efficient and innovative,
fearless and careful, professional service.
Notes from company
- Orders: Medical spares and accessories with bulk stock and favourable
price, and orders could be accepted and arranged anytime.
- Payment terms: T/T, Western Union, Paypal are acceptable. 100% prepaid before
shipping.
- Worldwide Shipping: DHL, UPS, EMS, ACS etc., express is based on buyers’ choice.
Orders could be arranged within 1 work day after payment confirmed.
Tracking No. could be offered within 1 day after shipment.
- Return and repair: Shipping fee for returned item need to be charged half customers
and half seller. All second hand unit will be handled by one of our
certified and experienced engineer, repair service is possible.
- 1. Maintenance Services: ECG monitor, Defibrillator, Oximeter, Electrocardiograph, Fetal
monitor
- 2. Sell and Replace: Mainboard, Circuit board, Power strip/ panel, Battery, SP O2 and ECG module, Parameter module, Display screen, Touch screen,
Encoder, Keyboard plate, Sensor, Probe, Cable etc.
- 3. Service Brands: GE, , SPACELABS, SIEMENS, MINDRAY, NIHON KOHDEN, Endoscopy, TYCO,
NONIN, TOSHIBA, MEDISON, BIOSOUND, HITACHI, HP, ATL, ALOKA etc.
Common Faults Repair
- 1. Unbootable/ Unable to boot up 2. The module ( M3001A ) can’t
detect blood pressure.
- 3. The module can’t be connected. 4. Automatically disconnect.
- 5. The sphygmomanometer has a leak. 6. NIBP equipment failure.
- 7. Unable to contact. 8. Error reporting MMS disconnected.
- 9. False alarm MMS pull out. 10. Can’t load out.
- 11. ECG malfunctions. 12. ECG equipment out of order.
- 13. Software upgrades. 14. NIBP fails to inflate.
- 15. IBP equipment faults. 16. M3012A module can’t be detected.
- 17. Automatically restart. 18. The encoder can’t work.
- 19. Blue screen appears after startup. 20. No ECG signal.
- 21. Unable to enter the select menu. 22. Alarm occurs when starting
up, and the failure light is on.
- 23. Report CO2 plugging. 24. MMSL developing module faults.
- 25. M3015A / M3001A module faults. 26. No power display light.
- 27. NBP equipment faults. 28. ECG and oximeter equipment faults.
- 29. LCD lamp aging. 30. Inflated blood pressure does not indicate a
number.
- 31. The key plate is out of order. 32. Encoder failure.
- 33. Can’t inflate. 34. NIBP equipment faults.
- 35. SP O2 and ECG equipment fault. 36. Unable to charge.
- 37. The touch screen can’t work. 38. The screen shows double image.
- 39. Error code 1000. Error code 20004. 40. No alarm sounds.
Details introduction
(1) Repair and replace EGG, Defibrillator, Electrocardiogram
Monitoring , Fetal Monitor Oximeter and parts.
(2) Detect and judge Circuit Board, Power Stripe/Panel, ECG PCB,
SPO2 PCB, NIBP PCB, Display Screen , Touch Screen, Keyboard Plate,
Parameter PCB, Rotary Knob etc.
(3) Sell and replace all kinds of Power Supply, ECG PCB, SPO2
PCB,NIBP PCB, Display Screen, Touch Screen , Keyboard Plate,
Parameter PCB, Rotary Knob.
(4) Monitor/ Electrocardiograph for leasing, maintenance, guarantee
repairing and replacing.
| - Agilent M1460A Sensor, Intellivue G5-M109A, Intellivue MX40,
- M1205A , M1001A, M1012A, M1034A, M3001A, M3012A,M3014A,
M3015A,M3046A,
- MP2 X2,MP20,MP30, MP40, MP5, MP50 , MP60, MP70, MP80, MP90,
- V24E(M1204A), VM4, VM6, VM8,VS2+, VS3
|
GE | - B20, B20i, B30, B40, B40i, B650, B850,
- DASH1800, DASH2000, DASH2500, DASH3000, DASH5000, Cardiocap 5,
- Datex-Ohmeda S3/S4/S5, GE DT-4500, Marquette EAGLE 4000,
- PRO1000, PRO300,
- SOLAR8000, SOLAR8000i, SOLAR8000M,
- V100, SAM Smart, SAM80
|
Nihon Kohden | - BSM-2301A, BSM-2301K, BSM-2304A, BSM-2351A, BSM-2351C, BSM-4104A,
BSM-5106A
- GF-210R, MU-631KA, WEP-4204K, WEP-4208A
|
Mindray | - IMEC8, IMEC10, IMEC12,
- IPM8, IPM10, IPM12, IPM9800, MEC-1000, MEC-1200, MEC-200, MPM,
- PANORAMA, PM6000, PM1000, PM8000, PM8000E, PM9000, PM9000E,
- T1, T5, T6, T8, VS-800
|
Spacelabs | - 90309, 90369, 90518,91369, 91370, 91387, 91388, 91393, 91496,
91518,
- elance93300,mCare300
|
Siemens | - SC6002,SC6000,SC7000,SC6002 XL
|
Tyco | |