Home Companies Guangzhou YIGU Medical Equipment Service Co.,Ltd

Green Patient Monitor Power Supply 13544CA GE Corometrics Isolated Power Supply Board PN 13544CA

Guangzhou YIGU Medical Equipment Service Co.,Ltd

Contact Us

[China] country

Trade Verify

Address: Room 206, Jin Hao Zhi Ying centre Buliding, Fengxin Road NO.1, Science avenue, Luo Gang District Guangzhou Guangdong China

Contact name:chamY

Inquir Now

Guangzhou YIGU Medical Equipment Service Co.,Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Green Patient Monitor Power Supply 13544CA GE Corometrics Isolated Power Supply Board PN 13544CA

Country/Region china
City & Province guangzhou guangdong
Categories Switching Power Supply
InquireNow

Product Details

Patient Monitor 13544CA Power Supply GE Corometrics Isolated Power Supply Board PN:13544CA
 
Product Description:
 
Product Name: Power Supply
 
Brand Name: GE
 
Part Number: 13544CA
 
1. Sell and Replace: Mainboard, Circuit board, Power strip/ panel, Battery, SP O2 and ECG module, Parameter module, Display screen, Touch screen, Encoder, Keyboard plate, Sensor, Probe, Cable etc.
 
2. Maintenance Services: ECG monitor, Defibrillator, Oximeter, Electrocardiograph, Fetal monitor
 
3. Service Brands: GE, , SPACELABS, SIEMENS, MINDRAY, NIHON KOHDEN, Endoscopy, TYCO, NONIN, TOSHIBA, MEDISON, BIOSOUND, HITACHI, HP, ATL, ALOKA etc.

 

 

Notes from company

  • Orders: Medical spares and accessories with bulk stock and favourable price, and orders could be accepted and arranged anytime.
  • Return and repair: Shipping fee for returned item need to be charged half customers and half seller. All second hand unit will be handled by one of our certified and experienced engineer, repair service is possible.
  • Payment terms: T/T, Western Union, Paypal are acceptable. 100% prepaid before shipping.
  • Worldwide Shipping: DHL, UPS, EMS, ACS etc., express is based on buyers’ choice. Orders could be arranged within 1 work day after payment confirmed. Tracking No. could be offered within 1 day after shipment.

 
Common Faults Repair
1. Unbootable/ Unable to boot up  2. The module ( M3001A ) can’t detect blood pressure.
3. The module can’t be connected.  4. Automatically disconnect.
5. The sphygmomanometer has a leak.  6. NIBP equipment failure.
7. Unable to contact.  8. Error reporting MMS disconnected.
9. False alarm MMS pull out. 10. Can’t load out.
11. ECG malfunctions.  12. ECG equipment out of order.
13. Software upgrades.  14. NIBP fails to inflate.
15. IBP equipment faults.  16. M3012A module can’t be detected.
17. Automatically restart.  18. The encoder can’t work.
19. Blue screen appears after startup.  20. No ECG signal.
21. Unable to enter the select menu.  22. Alarm occurs when starting up, and the failure light is on.
23. Report CO2 plugging.  24. MMSL developing module faults.
25. M3015A / M3001A module faults.  26. No power display light.
27. NBP equipment faults.  28. ECG and oximeter equipment faults.
29. LCD lamp aging.  30. Inflated blood pressure does not indicate a number.
31. The key plate is out of order.  32. Encoder failure.
33. Can’t inflate.  34. NIBP equipment faults.
35. SP O2 and ECG equipment fault.  36. Unable to charge.
37. The touch screen can’t work.  38. The screen shows double image.
39. Error code 1000. Error code 20004.  40. No alarm sounds.
 

 

Company Business Scopes

  • A. ECG monitor, Fetal monitor, Defibrillator, Electrocardiograph, Oximeter for repairing and accessories for selling.
  • B. Mainboard, Power Stripe/Panel, Touch Screen, Viewing screen, Button Board, ECG/Oximeter/Blood Press Module for repairing and selling.
  • C. Medical Patient Monitor/Electrocardiograph for leasing, maintenance, guarantee repair and exchange.

 

  • Agilent M1460A Sensor, Intellivue G5-M109A, Intellivue MX40,
  • M1205A , M1001A, M1012A, M1034A, M3001A, M3012A,M3014A, M3015A,M3046A,
  • MP2 X2,MP20,MP30, MP40, MP5, MP50 , MP60, MP70, MP80, MP90,
  • V24E(M1204A), VM4, VM6, VM8,VS2+, VS3
GE

 

  • B20, B20i, B30, B40, B40i, B650, B850,
  • DASH1800, DASH2000, DASH2500, DASH3000, DASH5000, Cardiocap 5,
  • Datex-Ohmeda S3/S4/S5, GE DT-4500, Marquette EAGLE 4000,
  • PRO1000, PRO300,
  • SOLAR8000, SOLAR8000i, SOLAR8000M,
  • V100, SAM Smart, SAM80
Nihon Kohden

 

  • BSM-2301A, BSM-2301K, BSM-2304A, BSM-2351A, BSM-2351C, BSM-4104A, BSM-5106A
  • GF-210R, MU-631KA, WEP-4204K, WEP-4208A
Mindray

 

  • IMEC8, IMEC10, IMEC12,
  • IPM8, IPM10, IPM12, IPM9800, MEC-1000, MEC-1200, MEC-200, MPM,
  • PANORAMA, PM6000, PM1000, PM8000, PM8000E, PM9000, PM9000E,
  • T1, T5, T6, T8, VS-800
Spacelabs

 

  • 90309, 90369, 90518,91369, 91370, 91387, 91388, 91393, 91496, 91518,
  • elance93300,mCare300
Siemens
  • SC6002,SC6000,SC7000,SC6002 XL
Tyco
  • NBP4000, NBP4000C

 






































Hot Products

Medical Accessories Mindray VS900 Monitor NIBP with Valve PN:051-000929-00 In Stocks For Selling ...
GE 170 Series fetal monitor repair For medical patient monitor GE 170 Series fetal monitor repair ...
Medical Accessories Drager REF 8403735 Flow Sensor In Stocks For Selling About YIGU MED Guangzhou ...
Medical Facility GE Corometrics 120Series Fetal Monitor in Stocks For Selling and Repairing Services ...
Medical Spare Parts GE TRUSAT Oximeter Mainboard In Stocks For Selling And Repairing YIGU MED ...
MP40 MP50 Patient Monitor Power Supply Module PN:M80003-60002 TNR149501-41004 In Stocks For Medical ...